REFERENCES
- “Official Statistics of Finland 2007. Labour Force Statistics. Labour Market” . [Online] Available at http://tilastokeskus.fi/til/tyti/index_en.html (Accessed September 2008)
- Reijula , K. and Sundman-Digert , C. 2004 . Assessment of indoor air problems at work with a questionnaire . Occup. Environ. Med. , 61 : 33 – 38 .
- Andersson , K. , Bakke , J.V. and Bjørseth , O. 1997 . TVOC and health in non-industrial indoor environments . Indoor Air , 7 : 78 – 91 .
- Mølhave , L. , Clausen , G. and Berglund , B. 1997 . Total volatile organic compounds (TVOC) in indoor air quality investigations . Indoor Air , 7 : 225 – 240 .
- Wolkoff , P. 2003 . Trends in Europe to reduce the indoor pollution of VOCs . Indoor Air , 13 : 5 – 11 .
- Wolkoff , P. and Nielsen , G.D. 2001 . Organic compounds in indoor air—Their relevance for perceived indoor air quality . Atmos. Environ. , 35 : 4407 – 4417 .
- Diez , U. , Kroessner , T. Rehwagen , M. 2000 . Effects of indoor painting and smoking on airway symptoms in atopy risk children in the first year of life—Results of the LARS study . Int. J. Hyg. Environ. Health , 203 : 23 – 28 .
- Rehwagen , M. , Krumbiegel , P. , Koschny , I. , Rolle-Kampczyk , U. and Herbarth , O. 2001 . The [15N] methacetin liver function test characterizes multicomponent exposure of children in industrially polluted regions . Isotopes Environ. Health Stud. , 37 : 167 – 174 .
- European Commission (EC) . 1994 . Sampling Strategies for Volatile Organic Compounds (VOCs) in Indoor Air , Brussels : European Commission . (Report No. 14, EUR 16051 EN)
- Becher , J. , Hongslo , J.K. and Dybing , E. 2000 . Guidelines for indoor air in Norway . Pollut. Atmos. , 166 : 245 – 246 .
- Wolkoff , P. , Clausen , P.A. , Jensen , B. , Nielsen , G.D. and Wilkins , C.K. 1997 . Are we measuring the relevant indoor pollutants? . Indoor Air , 7 : 92 – 106 .
- Weschler , C.J. and Shields , H.C. 1997 . Potential reactions among indoor pollutants . Atmos. Environ. , 31 : 3487 – 3495 .
- Wolkoff , P. , Clausen , P.A. , Wilkins , C.K. and Nielsen , G.D. 2000 . Formation of strong airway irritants in terpene/ozone mixtures . Indoor Air , 10 : 82 – 91 .
- Wolkoff , P. , Nøjgaard , J.K. , Franck , C. and Skov , P. 2006 . The modern office environment desiccates the eyes? . Indoor Air , 16 : 258 – 265 .
- Alarie , Y. , Nielsen , G.D. , Andonian-Haftvan , J. and Abraham , M.H. 1995 . Physicochemical properties of nonreactive volatile organic chemicals to estimate RD50: Alternatives to animals studies . Toxicol. Appl. Pharmacol. , 134 : 92 – 99 .
- Schaper , M. 1993 . Development of a database for sensory irritants and its use in establishing occupational exposure limits . Am. Ind. Hyg. Assoc. J. , 54 : 488 – 544 .
- Nielsen , G.D. , Alarie , Y. , Poulsen , O.M. and Andersen Nexo , B. 1995 . Possible mechanisms for the respiratory tract of noncarcinogenic indoor-climate pollutants and bases for their risk assessment . Scand. J. Work Environ. Health , 21 : 165 – 178 .
- Health Canada . 1993 . Indoor Air Quality in Office Buildings: A Technical Guide , Ottawa, Ontario, , Canada : Environmental Health Directorate, Health Protection Branch, Health Canada . (93-EHD-166)
- Mølhave , L. , Clausen , G. Berglund , B. 1997 . Total volatile organic compounds (TVOC) in indoor air quality investigations . Indoor Air , 7 : 225 – 240 .
- Alarie , Y. , Schaper , M. , Nielsen , G.D. and Abraham , M.H. 1996 . Estimating the sensory irritating potency of airborne nonreactive volatile organic chemicals and their mixtures . SAR QSAR Environ. Res. , 5 : 151 – 165 .
- International Agency for Research on Cancer (IARC) . 2006 . Monographs on the Evaluation of Carcinogenic Risk to Humans. Formaldehyde, 2-Butoxyethanol and 1-tert-Butoxypropan-2-ol , Volume 88 , Lyon, , France : IARC .
- Andersson , K. 1998 . Epidemiological approach to indoor problems . Indoor Air Suppl. , 4 : 32 – 39 .
- Andersson , K. and Stridh , G. 1992 . “ The use of standardized questionnaires in building related illness (BR) and sick building syndrome (SBS) surveys ” . In NATO/CCMS Pilot Study on Indoor Air Quality , 47 – 64 . Oslo, , Norway : National Institute of Occupational Health .
- Kasanen , J.-P. , Pasanen , A.-L. , Liesivuori , J. , Kosma , V.M. and Alarie , Y. 1998 . Stereospecificity of the sensory irritation receptor for nonreactive chemicals illustrated by pinene enantiomers . Arch. Toxicol. , 72 : 514 – 523 .
- Korsak , Z. , Swiercz , R. and Jedrychowski , R. 1993 . Effects of acute combined exposure to n-butyl alcohol and m-xylene . Pol. J. Occup. Med. Environ. Health , 6 : 35 – 41 .
- Kristiansen , U. and Nielsen , G.D. 1988 . Activation of the sensory irritant receptor by C7-C11 n-alkanes . Arc. Toxicol. , 61 : 419 – 425 .
- Pasanen , A.-L. , Korpi , A. , Kasanen , J.P. and Pasanen , P. 1998 . Critical aspects on the significance of microbial volatile metabolites as indoor air pollutants . Environ. Int. , 24 : 703 – 712 .
- Nielsen , G.D. , Hougaard , K.S. Larsen , S.T. 1999 . Acute airway effects of formaldehyde and ozone in BALB/c mice . Hum. Exp. Toxicol. , 18 : 400 – 409 .
- Alarie , Y. , Schaper , M. , Nielsen , G.D. and Abraham , M.H. 1998 . Structure-activity relationships of volatile organic chemicals as sensory irritants . Arch. Toxicol. , 72 : 125 – 140 .
- Mitchell , C.S. , Zhang , J. Sigsgaard , T. 2007 . Current state of the science: Health effects and indoor environmental quality . Environ. Health Perspect. , 115 : 958 – 964 .
- Wolkoff , P. , Wilkins , C.K. , Clausen , P.A. and Nielsen , G.D. 2006 . Organic compounds in office environments—Sensory irritation, odor, measurements and the role of reactive chemistry . Indoor Air , 16 : 7 – 19 .
- Wolkoff , P. , Skov , P. , Franck , C. and Pedersen , L.N. 2003 . Eye irritation and environmental factors in the office environment. Hypotheses, causes, and a physiological model . Scand. J. Work Environ. Health , 29 : 411 – 430 .
- American Society of Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE) . 1989 . Ventilation for Acceptable Indoor Air Quality , 62 – 1989 . New York : ASHRAE . [Standard]
- Arts , J.H.E. , Rennen , M.A.J. and de Heer , C. 2006 . Inhaled formaldehyde: Evaluation of sensory irritation in relation to carcinogenicity . Regul. Toxicol. Pharmacol. , 44 : 144 – 160 .
- World Health Organization (WHO) . 1999 . Air Quality Guidelines for Europe , Geneva : World Health Organization .
- Mendell , M. 2007 . Indoor residential chemical emissions as risk factors for respiratory and allergic effects in children: A review . Indoor Air , 17 : 259 – 277 .
- Hodgson , M. 2002 . Indoor environmental exposure and symptoms . Environ. Health Perspect. , 110 : 663 – 667 .
- ACGIH® . 1999 . Bioaerosols: Assessment and Control , Edited by: Macher , J. Cincinnati, Ohio : ACGIH .
- Engvall , K. , Norrby , C. and Norback , D. 2002 . Ocular, airway, and dermal symptoms related to building dampness and odors in dwellings . Arch. Environ. Health , 57 : 304 – 310 .
- Doty , R.L. , Cometto-Muniz , J.E. , Jalowayski , A.A. , Dalton , P. , Kendall-Ree , M. and Hodgson , M. 2004 . Assessment of upper respiratory tract and ocular irritative effects of volatile chemicals in humans . Crit. Rev. Toxicol. , 34 : 85 – 142 .
- Brightman , H.S. and Moss , N. 2000 . “ Sick building syndrome studies and the compilation of normative and comparative values ” . In Indoor Air Quality Handbook , Edited by: Spengler , J. , Samet , J.M. and McCarthy , J.F. 3.1 – 3.32 . New York : McGraw-Hill .
- Rolando , M. , Macri , A. , Carlandrea , T. and Calabria , G. 1998 . “ Use of a questionnaire for the diagnosis of tear film-related ocular surface disease ” . In Lacrimal Gland, Tear Film, and Dry Eye Syndromes , Edited by: Sullivan , D.A. 821 – 825 . New York : Plenum Press .
- Doughty , M.J. , Blades , K.A. and Ibrahim , N. 2002 . Assessment of the number of eye symptoms and the impact of some confounding variables for office staff in non-air-conditioned buildings . Ophthalmic Physiol. Opt. , 22 : 143 – 155 .
- Hodgson , M.J. , Frohliger , J. Permar , E. 1991 . Symptoms and microenvironmental measures in nonproblem buildings . J. Occup. Med. , 33 : 527 – 533 .
- DeBortoli , M. , Knöppel , H. Peil , A. July 29–August 3 1990 . “ Investigation on the contribution of volatile organic compounds to air quality complaints in office buildings of the European Parliament ” . In Proceedings of the Fifth International Conference on Indoor Air Quality and Climate: Indoor Air ′90, Toronto (Canada) Vol. 5 , July 29–August 3 , 605 – 610 . Walkinshaw, D.S.
- Wolkoff , P. , Nojgaard , J.K. , Troiano , P. and Piccoli , B. 2005 . Eye complaints in the office environment: Precorneal tear film integrity influenced by eye blinking efficiency . Occup. Environ. Med. , 62 : 4 – 12 .
- Berglund , B. and Lindvall , T. 1986 . Sensory reactions to sick buildings . Environ. Int. , 12 : 147 – 159 .
- Jaakkola , J.J.K. 1998 . The office environment model: a conceptual analysis of the sick building syndrome . Indoor Air Suppl. , 4 : 7 – 16 .
- Bullinger , M. , Morfeld , M. , von Machensen , S. and Brasche , S. 1999 . The sick-building-syndrome—Do women suffer more? . Zentralbl. Hyg. Umweltmed. , 202 : 235 – 241 .