  • Lau , A. K. and Hui , D. 2002 . The revolutionary creation of new advanced materials—Carbon nanotube composites . Compos. Part-B Eng. , 33 ( 4 ) : 263 – 277 .
  • Hansen , S. F. , Michelson , E. S. Kamper , A. 2008 . Categorization framework to aid exposure assessment of nanomaterials in consumer products . Ecotoxicology , 17 : 438 – 447 .
  • Lam , C. , James , J. T. McCluskey , R. 2006 . A review of carbon nanotube toxicity and assessment of potential occupational and environmental health risks . Crit. Rev. Toxicol. , 36 ( 3 ) : 189 – 217 .
  • Tejral , G. , Panyala , N. R. and Havel , J. 2009 . Carbon nanotubes Toxicological impact on human health and environment . J. Appl. Biomed , 7 : 1 – 13 .
  • Lam , C. W. , James , J. T. McCluskey , R. 2004 . Pulmonary toxicity of single-wall carbon nanotubes in mice 7 and 90 days after intratracheal instillation . Toxicologic. Sci. , 77 : 126 – 134 .
  • Warheit , D. B. , Laurence , B. R. Reed , K. L. 2003 . Comparative pulmonary toxicity assessment of single-wall carbon nanotubes in rats . Toxicol. Sci. , 77 : 117 – 125 .
  • Muller , J. , Huaux , F. Moreau , N. 2005 . Respiratory toxicity of multi-wall carbon nanotubes . Toxicol. Appl. Pharmacol. , 207 ( 3 ) : 221 – 231 .
  • Shvedova , A. A. , Kisin , E. R. Mercer , R. 2005 . Unusual inflammatory and fibrogenic pulmonary responses to single walled carbon nanotubes in mice . Am. J. Physiol. Lung Cell. Mol. Physiol. , 289 ( 5 ) : L698 – L708 .
  • Shvedova , A. A. , Castranova , V. and Kisin , E. R. 2003 . Exposure to carbon nanotube material: Assessment of nanotube cytotoxicity using human keratocyte cells . J. Toxicol. Environ. Health Par , A 66 : 1909 – 1926 .
  • Li , Z. , Huldermen , T. Salmen , R. 2007 . Cardiovascular effects of pulmonary exposure to single-wall carbon nanotubes . Environ. Health Perspect. , 115 ( 3 ) : 377 – 382 .
  • Monteiro-Riviere , N. A. , Nemanich , R. J. Inman , A. O. 2005 . Multi-walled carbon nanotube interactions with human epidermal keratinocytes . Toxicol. Lett. , 155 : 377 – 384 .
  • National Institute of Occupational Safety and Health (NIOSH) . 2003 . Evaluation of Aerosol Release during the Handling of Unrefined Single Walled Carbon Nanotube Material , Edited by: Baron , P. A. , Maynard , A. D. and Foley , M. Cincinnati, Ohio : NIOSH . NIOSH DART-02-191
  • Maynard , A. D. , Baron , P. A. Foley , M. 2004 . Exposure to carbon nanotube material: Aerosol release during the handling of unrefined single walled carbon nanotube material . J. Toxicol. Environ. Healt , 67 : 87 – 107 .
  • Köhler , A. R. , Som , C. Helland , A. 2008 . Studying the potential release of carbon nanotubes throughout the application life cycle . J. Clean. Prod. , 16 : 927 – 937 .
  • Tsai , S. J. , Ada , E. Isaacs , J. A. 2009 . Airborne nanoparticle exposures associated with the manual handling of nanoalumina and nanosilver in fume hoods . J. Nanopart. Res. , 11 : 147 – 161 .
  • ACGIH . 2009 . 2009 TLVs and BEIs , Cincinnati, Ohio : ACGIH .
  • Brockmann , J. E. 2001 . “ Sampling and transport of aerosol ” . In Aerosol Measurement: Principles, Techniques, and Applications , 2nd Ed. , Edited by: Baron , P. A. and Willeke , K. New York : Wiley Interscience .
  • Volkwein , J. C. and Peters , T. M. 2003 . Analysis of sampling line bias on respirable mass measurement . Appl. Occup. Environ. Hyg. , 18 ( 6 ) : 458 – 465 .
  • American National Standards Institute (ANSI), and American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE) . 1995 . Method of Testing Performance of Laboratory Fume Hoods , Atlanta : ASHRAE . (ANSI/ASHRAE 110–1995). [Standard]
  • Mowat , F. , Bono , M. Lee , R. J. 2005 . Occupational exposure to airborne asbestos from phenolic molding material (Bakelite) during sanding, drilling, and related activities . J. Occup. Environ. Hyg. , 2 : 497 – 507 .
  • Wunder , J. 2000 . Quantitative fume hood evaluation for operator safety . Chem. Health Saf. , 7 ( 4 ) : 26 – 30 .
  • ACGIH . 2007 . Industrial Ventilation—A Manual of Recommended Practices , 26th Ed. , Cincinnati, Ohio : ACGIH .
  • Huang , R. F. and Chou , C. I. 2009 . Flow and performance of an air-curtain biological safety cabinet . Ann. Occup. Hyg. , 53 ( 4 ) : 425 – 440 .
  • Kruse , R. H. , Puckett , W. H. and Richardson , J. H. 1991 . Biological safety cabinetry . Clin. Microbiol. Rev. , 4 ( 2 ) : 207 – 241 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.