REFERENCES
- Rengasamy , S. and Eimer , B. C. 2012 . Nanoparticle penetration through filter media and leakage through face seal interface of N95 filtering fasf cepiece respirators . Ann. Occup. Hyg. , 56 ( 5 ) : 568 – 580 .
- Roberge , R. , Niezgoda , G. and Benson , S. 2012 . Analysis of forces generated by N95 filtering facepiece respirator tethering devices: A pilot study . J. Occup. Environ. Hyg. , 9 : 517 – 523 .
- Lei , Z. , Yang , J. and Zhuang , Z. 2012 . Headform and N95 filtering facepiece respirator interaction: Contact pressure simulation and validation . J. Occup. Environ. Hyg. , 9 : 46 – 58 .
- Grinshpun , S. A. , Haruta , H. , Eninger , R. M. , Reponen , T. , McKay , R. T. and Lee , S-A. 2009 . Performance of a N95 filtering facepiece particulate respirator and a surgical mask during human breathing: Two pathways for particle penetration . J. Occup. Environ. Hyg. , 6 : 593 – 603 .
- Yang , J. and Lei , Z. Computational Fluid Dynamics for Respirator Fit and Leak Locations . Available at http://www.aiha.org/education/meetings-conferences/aihce/archivedabstracts/2012abstracts/Documents/2012%20Respiratory%20Protection%20Abstracts.pdf (accessed August 15, 2012)
- Snook , S. H. , Hinds , W. C. and Burgess , W. A. 1966 . Respirator comfort: Subjective response to force applied to the face . Am. Ind. Hyg. Assoc. J. , 27 : 93 – 97 .
- Radonovich , L. J. Jr. , Cheng , J. , Shenal , B. V. , Hodgson , M. and Bender , B. S. 2009 . Respirator tolerance in health care workers . JAMA , 301 ( 10 ) : 36 – 38 .
- Yang , J. , Dai , J. and Zhuang , Z. 2009 . Simulating the interaction between a respirator and a headform using LS-DYNA . Computer-Aided Design Appl. , 6 ( 4 ) : 539 – 551 .
- Roberge , R. J. , Bayer , E. , Powell , J. B. , Coca , A. , Roberge , M. R. and Benson , S. M. 2010 . Effect of exhaled moisture on breathing resistance of N95 filtering facepiece respirators . Ann. Occup. Hyg. , 54 ( 6 ) : 671 – 677 .
- Roberge , R. , Benson , S. and Kim , J.-H. 2012 . Thermal burden of N95 filtering facepiece respirators . Ann. Occup. Hyg. , 56 ( 7 ) : 808 – 814 .
- Roberge , R. J. , Kim , J.-H. and Benson , S. M. 2012 . Absence of consequential changes in physiological, thermal and subjective responses from wearing a surgical mask . Resp. Physiol. Neurobiol. , 181 ( 1 ) : 29 – 35 .
- Kim , J.-H. , Benson , S. M. and Roberge , R. J. 2013 . Pulmonary and heart rate responses to wearing N95 filtering facepiece respirators . Am. J. Infect. Control. , 41 ( 1 ) : 24 – 27 .
- Occupational Safety and Health Administration (OSHA) . Appendix A to §1910.134: Fit Testing Procedures (Mandatory) . Available at http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_id=9780&p_table=STANDARDS (accessed August 3, 2012)
- Occupational Safety and Health Administration (OSHA) . Appendix B-1 to §1910.134: User Seal Check Procedures (Mandatory) . Available at http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table = STANDARDS&p_id = 9781 (accessed August 16, 2012)
- Yu , Y. , Benson , S. and Cheng , W. 2012 . Digital 3-D headforms representative of Chinese workers . Ann. Occup. Hyg. , 56 ( 1 ) : 113 – 122 .
- Aldridge , K. , Boyadjiev , S. A. , Capone , G. T. , DeLeon , V. B. and Richtsmeier , J. T. 2005 . Precision and error of three-dimensional phenotypic measures acquired from 3dMD photogrammetric images . Am. J. Med. Genet. , 138A : 247 – 253 .
- Lei , Z. , Yang , J. and Zhuang , Z. 2010 . Contact pressure study of N95 filtering face-piece respirators using finite element method . Computer-Aided Design Appl. , 7 ( 6 ) : 847 – 861 .
- Zhuang , Z. , Coffey , C. C. and Ann , R. B. 2005 . The effect of subject characteristics and respirator features on respirator fit . J. Occup. Environ. Hyg. , 2 : 641 – 649 .
- Lee , K. , Slavcev , A. and Nicas , M. 2004 . Respiratory protection against Mycobacterium tuberculosis: Quantitative fit test outcomes for five type N95 filtering-facepiece respirators . J. Occup. Environ. Hyg. , 1 : 22 – 28 .
- Brosseau , L. M. Toward Better Fitting Respirators . Available at http://www.sph.umn.edu/pdf/ce/nofit/Final_NoFitRespiratorReport_July28_2009.pdf (accessed August 21, 2012)