710
Views
15
CrossRef citations to date
0
Altmetric
Original Articles

Criteria for the Collection of Useful Respirator Performance Data in the Workplace

, &

REFERENCES

  • 2005 . Respiratory Protection . Code of Federal Regulations Title , 29 : 419 – 444 . Section 1910.134
  • American Industrial Hygiene Association (AIHA): “Respiratory Protection Committee Research Needs in Respiratory Protection,” White Paper . Available at http://www.aiha.org/news-pubs/govtaffairs/Pages/PositionStatements.aspx (accessed December 12, 2012)
  • 2011 . Control of Exposure to Airborne Contaminants . Code of Federal Regulations Title 30 , : 300 Section 56.5005
  • 2011 . Control of Exposure to Airborne Contaminants . Code of Federal Regulations Title 30 , : 366 – 367 . Section 57.5005
  • 2012 . Use of Individual Respiratory Protection Equipment . Code of Federal Regulations Title 10 , : 364 – 365 . Section 20.1703
  • Los Alamos Scientific Laboratory: “Respirator Protection Factors,” by E.C. Hyatt, Los Alamos Scientific Laboratory, Los Alamos, N.M., 1976. [Report No. LA-6084-MS] .
  • 1985 . American Industrial Hygiene Association (AIHA) Respiratory Protection Committee: Respirator performance terminology. [Letter to the Editor] . Am. Ind. Hyg. Assoc. J. , 46 : B22 – 23 .
  • 2002 . American Industrial Hygiene Association (AIHA) Respiratory Protection Committee: Respirator performance terminology. [Letter to the Editor] . Am. Ind. Hyg. Assoc. J. , 63 : 132
  • Moore , D. E and Smith , T. J. 1976 . Measurement of protection factors of chemical cartridge, half-mask respirators under working conditions in a copper smelter . Am. Ind. Hyg. Assoc. J. , 5337 ( 8 ) : 453 – 458 .
  • Smith , T. J. , Ferrell , W. C. , Varner , M. O. and Puttnam , R. D. 1980 . Inhalation exposure of cadmium workers: Effects of respirator use . Am. Ind. Hyg. Assoc. J. , 41 ( 9 ) : 624 – 629 .
  • Samimi , B. , Neilson , A. , Weill , H. and Ziskind , M. 1975 . The efficiency of protective hoods used by sandblasters to reduce silica dust exposure . Am. Ind. Hyg. Assoc. J. , 36 : 140 – 148 .
  • Johnston , A. R. , Myers , W. R. , Colton , C. E. , Birkner , J. S. and Campbell , C. E. 1992 . Review of respirator performance testing in the workplace: issues and concerns . Am. Ind. Hyg. Assoc. J. , 37 ( 8 ) : 453 – 458 .
  • Myers , W. R. , Zhuang , Z. , Nelson , T. J. , Sides , S. and Wilmes , D. 1995 . Field performance measurements of half-facepiece respirators-Study protocol . Am. Ind. Hyg. Assoc. J. , 56 : 765 – 775 .
  • Myers , W. R. and Zhuang , Z. 1996 . Field performance measurements of half facepiece respirators: Foundry operations . Am. Ind. Hyg. Assoc. J. , 57 : 166 – 174 .
  • Zhuang , Z. and Myers , W. R. 1996 . Field performance measurements of half facepiece respirators: Paint spraying operations . Am. Ind. Hyg. Assoc. J. , 57 : 50 – 57 .
  • Myers , W. R. and Zhuang , Z. 1998 . Field performance measurements of half facepiece respirators: Steel mill operations . Am. Ind. Hyg. Assoc. J. , 59 : 789 – 795 .
  • Nelson , T. J. , Wheeler , T. H. and Mustard , T. S. 2001 . Workplace protection factors—Supplied air hood . AIHAJ. , 62 : 96 – 100 .
  • Zhuang , Z. , Coffey , C. C. , Jensen , P. A. , Campbell , D. L. , Lawrence , R. B. and Myers , W. R. 2003 . Correlation between quantitative fit factors and workplace protection factors measured in actual workplace environments at a steel foundry . Am. Ind. Hyg. Assoc. J. , 64 : 730 – 738 .
  • Bidwell , J. O. and Janssen , L. L. 2004 . Workplace performance of an N95 respirator in a concrete block manufacturing plant . J. Int. Soc. Resp. Prot. , 21 ( III–IV ) : 94 – 102 .
  • Janssen , L. L. and Bidwell , J. O. 2007 . Performance of a full facepiece, air purifying respirator against lead aerosols in a workplace environment . J. Occup. Environ. Hyg. , 4 : 123 – 128 .
  • Janssen , L. L. , Nelson , T. J. and Cuta , K. T. 2007 . Workplace protection factors for an N95 filtering facepiece respirator . J. Occup. Environ. Hyg. , 4 : 698 – 707 .
  • Janssen , L. L. , Bidwell , J. O. , McCullough , N. V. and Nelson , T. J. 2007 . Performance of an N95 filtering facepiece respirator in a grinding operation . J. Int. Soc. Respir. Prot. , 24 : 21 – 31 .
  • Janssen , L. L. , Bidwell , J. O. , Cuta , K. T. and Nelson , T. J. 2008 . Workplace performance of a hood-style supplied-air respirator . J. Occup. Environ. Hyg. , 5 : 438 – 443 .
  • Janssen , L. L. and McCullough , N. V. 2009 . Elastomeric, half-facepiece, air-purifying respirator performance in a lead battery plant . J. Occup. Environ. Hyg. , 7 : 46 – 53 .
  • Crutchfield , C. D. , Murphy , R. W. and Van Ert , M. D. 1993 . A comparison of controlled negative pressure and aerosol quantitative respirator fit test systems by using human subjects . Am. Ind. Hyg. Assoc. J. , 54 ( 1 ) : 10 – 14 .
  • Crutchfield , C. D. , Fairbank , E. O. and Greenstein , S. L. 1999 . Effect of test exercises and mask donning on measured respirator fit . Appl. Occup. Environ. Hyg. , 14 ( 12 ) : 827 – 837 .
  • Lee , S. A. , Adhikari , A. and Grinshpun , S. A. 2005 . Respiratory protection provided by N95 filtering facepiece respirators against airborne dust and microorganisms in agricultural farms . J. Occup. Environ. Hyg. , 2 : 577 – 575 .
  • Cho , K. J. , Jones , S. Jones , G. 2010 . Effect of particle size on respiratory protection provided by two types of N95 respirators used in agricultural settings . J. Occup. Environ. Hyg. , 7 : 622 – 627 .
  • Cho , K. J. , Reponen , T. McKay , R. 2011 . Comparison of workplace protection factors for different biological contaminants . J. Occup. Environ. Hyg. , 8 : 417 – 425 .
  • Janssen , L. L. , Bidwell , J. O. , Mullins , H. E. and Nelson , T. J. 2003 . Efficiency of degraded electret filters: Part 1-Laboratory testing against NaCl and DOP before and after exposure to workplace aerosols . J. Int. Soc. Respir. Prot. , 20 ( 2 ) : 71 – 80 .
  • Nelson , T. J. and Colton , C. E. 2000 . The effect of inhalation resistance on facepiece leakage . Am. Ind. Hyg. Assoc. J. , 61 : 102 – 105 .
  • Janssen , L. L. and Weber , R. A. 2005 . The effect of pressure drop on respirator faceseal leakage . J. Occup. Environ. Hyg. , 2 : 335 – 340 .
  • 2007 . International Organization for Standardization (ISO): Respiratory Protective Devices—Human Factors—Part 1: Metabolic Rates and Res- piratory Flow Rates (ISO/TS 16976-1). [Standard] , Geneva : ISO .
  • 2012 . Approval of Respiratory Protective Devices . Code of Federal Regulations Title 42 , : 604 – 607 . Part 84
  • Janssen , L. L. , Luinenburg , M. D. , Mullins , H. E. , Danisch , S. G. and Nelson , T. J. 2003 . Evaluation of a quantitative fit testing method for N95 filtering facepiece respirators . Am. Ind. Hyg. Assoc. J. , 63 : 480 – 486 .
  • Zhuang , Z. , Benson , S. , Lynch , S. , Palmiero , A. and Roberge , R. 2011 . Laboratory study to assess causative factors affecting temporal changes in filtering facepiece respirator fit: Part I - Pilot study . J. Occup. Environ. Hyg. , 8 : 729 – 739 .
  • Fairchild , C. I. and Stampfer , J. F. 1987 . Particle concentration in exhaled breath . Am. Ind. Hyg. Assoc. J. , 48 ( 11 ) : 948 – 949 .
  • Harrison , B. H. and Liang , S. H. 2005 . Quantitative fit testing of military gas masks with the TSI Portacount: Part II - Quantifying the limitations and recommendations for use . J. Int. Soc. Respir. Prot. , 22 : 55 – 67 .
  • Weber , R. A. and Mullins , H. E. 2000 . Measuring performance of a half-mask respirator in a styrene environment . AIHAJ. , 61 : 415 – 421 .
  • Coffey , C. C. , Campbell , D. L. Myers , W. R. 1998 . Comparison of six respirator fit-test methods with an actual measurement of exposure in a simulated health care environment: Part I - Protocol development . Am. Ind. Hyg. Assoc. J. , 59 : 852 – 861 .
  • Hewett , P. , Pallay , B. G. and Gamble , J. F. 1993 . A model for correcting workplace protection factors for lung deposition and other effects . Am. Ind. Hyg. Assoc. J. , 54 ( 4 ) : 142 – 149 .
  • Hinds , W. C. and Kraske , G. 1987 . Performance of dust respirators with facial seal leaks: I. Experimental . Am. Ind. Hyg. Assoc. J. , 48 ( 10 ) : 836 – 841 .
  • Hinds , W. C. and Bellin , P. 1993 . The effect of respirator dead space and lung retention on exposure estimates . Am. Ind. Hyg. Assoc. J. , 54 : 711 – 722 .
  • Chen , C. C. and Willeke , K. 1992 . Characteristics of face seal leakage in filtering facepieces . Am. Ind. Hyg. Assoc. J. , 53 ( 9 ) : 533 – 539 .
  • Chen , C. C. , Lehtimaki , M. and Willeke , K. 1992 . Aerosol penetration through filtering facepieces and respirator cartridges . Am. Ind. Hyg. Assoc. J. , 53 ( 9 ) : 566 – 574 .
  • Chen , C. C. , Lehtimaki , M. and Willeke , K. 1993 . Loading and filtration characteristics of filtering facepieces . Am. Ind. Hyg. Assoc. J. , 54 ( 2 ) : 51 – 60 .
  • Grinshpun , S. A. , Haruta , H. Eninger , R. M. 2009 . Performance of an N95 filtering facepiece particulate respirator and a surgical mask during human breathing: Two pathways for particle penetration . J. Occup. Environ. Hyg. , 6 : 593 – 603 .
  • Holton , P. M. , Tackett , D. L. and Willeke , K. 1987 . Particle size dependent leakage and losses of aerosols in respirators . Am. Ind. Hyg. Assoc. J. , 48 : 848 – 854 .
  • Hinds , W. C. and Bellin , P. 1987 . Performance of dust respirators with facial seal leaks: II. Predictive model . Am. Ind. Hyg. Assoc. J. , 48 ( 10 ) : 842 – 847 .
  • Krishnan , U. , Willeke , K. , Juozaitis , A. , Myojo , T. , Talaska , G. and Shukla , R. 1994 . Variation in quantitative respirator fit factors due to fluctuations in leak size during fit testing . Am. Ind. Hyg. Assoc. J. , 55 : 309 – 314 .
  • Janssen , L. L. and Weber , R. A. 2005 . The effect of pressure drop on respirator faceseal leakage . J. Occup. Environ. Hyg. , 2 : 335 – 340 .
  • Myers , W. R. , Allendar , J. R. Iskander , W. 1988 . Causes of in-facepiece sampling bias-I half-facepiece respirators . Ann. Occup. Hyg. , 32 ( 3 ) : 345 – 359 .
  • Myers , W. R. and Allendar , J. R. 1988 . Causes of in-facepiece sampling bias-II full-facepiece respirators . Ann. Occup. Hyg. , 32 ( 3 ) : 361 – 372 .
  • Hendricks , W. , Stones , F. and Lillquist , D. 2009 . On wiping the interior walls of 37-mm closed-face cassettes: An OSHA perspective . J. Occup. Environ. Hyg. , 6 ( 12 ) : 732 – 734 .
  • Chapter O. Factors Affecting Aerosol Sampling, 2003 . [Available at http://www.cdc.gov/niosh/docs/2003-154/pdfs/chapter-o.pdf (accessed August 8, 2013)
  • (24 August 2006 . Assigned Protection Factors; Final Rule . Federal Register , 71 : 164 – 50192 . 50122
  • Nicas , M. and Neuhaus , J. 2004 . Variability in respiratory protection and the assigned protection factor . J. Occup. Environ. Hyg. , 1 : 99 – 109 .
  • Crump , K. S. 2007 . Statistical issues with respect to workplace protection factors for respirators . J. Occup. Environ. Hyg. , 4 : 208 – 214 .
  • Methner , M. , Hodson , L. , Dames , A. and Geraci , C. 2010 . Nanoparticle emission assessment technique (NEAT) for the identification and measurement of potential inhalation exposure to engineered nanomaterials—Part b: Results from 12 field studies . J. Occup. Environ. Hyg. , 7 : 163 – 176 .
  • Lindsley , W. G. , Blachere , F. M. , Davis , K. A. Pearce , T. A. 2010 . Distribution of airborne influenza virus and respiratory syncytial virus in an urgent care medical clinic . Clin. Infect. Dis. , 50 ( 5 ) : 693 – 698 .
  • Yang , W. , Elankumaran , S. and Marr , L. C. 2011 . Concentrations and size distributions of airborne influenza A viruses measured indoors at a health centre, a day-care centre and on aeroplanes . J. R. Soc. Interface. , 8 : 1176 – 1184 .

APPENDIX

  • Bolsover , J. , Sithamparanadarajah , B. and Vaughn , N. 2006 . Workplace protection of air-fed visors used in paint spraying operations . Ann. Occup. Hyg. , 50 ( 3 ) : 219 – 229 .
  • Campbell , D. L. , Noonan , G. P. , Merinar , T. R. and Stobbe , J. A . 1994 . Estimated workplace protection factors for positive-pressure self-contained breathing apparatus . Am. Ind. Hyg. Assoc. J. , 55 ( 4 ) : 322 – 329 .
  • Clayton , M. P. , Sithamparanadarajah , B. and Vaughn , N. 2012 . Performance studies on respiratory protective devices in the workplace–Part I: Variation in measures of performance . J. Int. Soc. Respir. Prot. , 29 ( 1 ) : 30 – 40 .
  • Dixon , S. W. and Nelson , T. J. 1984 . Workplace protection factors for negative pressure half-mask facepiece respirators . J. Int. Soc. Respir. Prot. , 2 ( 4 ) : 347 – 360 .
  • Fergin , G. S. 1984 . Respirator evaluation for carbon setters with beards . Am. Ind. Hyg. Assoc. J. , 51 : 625 – 631 .
  • Gaboury , A. , Burd , D. H. and Friar , R. S. 1987 . Respiratory protective equipment in a primary aluminum smelter . Appl. Occup. Environ. Hyg. , 8 ( 1 ) : 53 – 56 .
  • Galvin , K. , Selvin , S. and Spear , R. C. 1990 . Variability in protection afforded by half mask respirators against styrene exposure in the field . Am. Ind. Hyg. Assoc. J. , 51 : 625 – 631 .
  • Groves , W. A. 2006 . Personal sampling system for measuring workplace protection factors for gases and vapors . J. Int. Soc. Respir. Prot. , 23 ( I–II ) : 30 – 43 .
  • Groves , W. A. and Reynolds , S. J. 2003 . Prototype sampling system for measuring workplace protection factors for gases and vapors . Appl. Occup. Environ. Hyg. , 18 ( 5 ) : 394 – 402 .
  • Han , D. 2002 . Correlations between workplace protection factors and fit factors for filtering facepieces in the welding workplace . Ind. Health. , 40 : 328 – 334 .
  • Hanley , K. W. and Lenhart , S. W. 2000 . Manganese dioxide exposures and respirator performance at an alkaline battery plant . Appl. Occup. Environ. Hyg. , 15 ( 7 ) : 542 – 549 .
  • Hery , M. , Meyer , J. P. Villa , M. 1993 . Measurement of workplace protection factors of six negative pressure half-masks . J. Int. Soc. Respir. Prot. , 11 ( 3 ) : 15 – 38 .
  • Hery , M. , Villa , M. , Hubert , G. and Martin , P. 1991 . Assessment of the performance of respirators in the workplace . Ann. Occup. Hyg. , 35 ( 2 ) : 181 – 187 .
  • Hewson , G. S. and Ralph , M. I. 1992 . Determination of program protection factors for half-mask respirators used at a mineral sands separation plant . Am. Ind. Hyg. Assoc. J. , 53 : 713 – 720 .
  • Lenhart , S. W. and Campbell , D. L. 1984 . Assigned protection factors for two respirator types based upon workplace performance testing . Ann. Occup. Hyg. , 28 : 173 – 182 .
  • Liu , Y. , Stowe , M. H. Bello , D. 2006 . Respiratory protection from isocyanate exposure in the autobody repair and refinishing industry . J. Occup. Environ. Hyg. , 3 : 234 – 249 .
  • Myers , W. R. and Peach , M. J. 1983 . Performance measurements on a powered air-purifying respirator made during actual field use in a silica bagging operation . Ann. Occup. Hyg. , 27 : 251 – 259 .
  • Myers , W. R. , Peach , M. J. and Allender , J. 1984 . Workplace protection factor measurements on powered air-purifying respirators at a secondary lead smelter-test protocol . Am. Ind. Hyg. J , 45 ( 4 ) : 236 – 241 .
  • Myers , W. R. , Peach , M. J. III , Cutright , K. and Iskander , W. 1984 . Workplace protection factor measurements on powered air-purifying respirators at a secondary lead smelter—Results and discussion . Am. Ind. Hyg. Assoc. J. , 45 : 681 – 688 .
  • Myers , W. R. , Peach , M. J. , Cutright , K. and Iskander , W. 1986 . Field test of powered air purifying respirators at a battery manufacturing facility . J. Int. Soc. Respir. Prot. , 4 ( 1 ) : 62 – 89 .
  • Poppendorf , W. , Merchant , J. A. Leonard , S. 1995 . Respirator protection and acceptability among agricultural workers . Appl. Occup. Environ. Hyg. , 10 ( 7 ) : 595 – 615 .
  • Que Hee , S. H. and Lawrence P , P. 1983 . Inhalation exposure to lead in brass foundry workers: The evaluation of the effectiveness of a powered air-purifying respirator and engineering controls . Am. Ind. Hyg. Assoc. J. , 44 : 746 – 751 .
  • Reed , L. D. , Lenhart , S. W. , Stephenson , R. L. and Allender , J. R. 1987 . Workplace evaluation of a disposable respirator in a dusty environment . Appl. Occup. Environ. Hyg. , 2 : 53 – 56 .
  • Riitta , R. E.E. and Riipinen , H. M. 1998 . Respirator and high efficiency particulate air filtration unit performance in asbestos abatement . Appl. Occup. Environ. Hyg. , 10 ( 7 ) : 32 – 41 .
  • Spear , T. M. , DuMond , J. , Lloyd , C. and Vincent , J. H. 2000 . An effective protection factor study of respirators used by primary lead smelter workers . Appl. Occup. Environ. Hyg. , 15 ( 2 ) : 235 – 244 .
  • Tannahill , S. N. , Willey , R. J. and Jackson , M. H. 1990 . Workplace protection factors of HSE approved negative pressure full-facepiece dust respirators during asbestos stripping preliminary findings . Ann. Occup. Hyg. , 34 ( 6 ) : 547 – 552 .
  • Vaughan , N. and Sithamparanadarajah , R. 2005 . Meaningful workplace protection factor measurements: Experimental protocols and data treatment . Ann. Occup. Hyg. , 49 ( 7 ) : 549 – 562 .
  • Wallis , G. , Menke , R. and Chelton , C. 1993 . Workplace field testing of a disposable negative pressure half-mask dust respirator (3M 8710) . Am. Ind. Hyg. Assoc. J. , 54 : 576 – 583 .
  • Wu , M. T. 2002 . Assessment of the effectiveness of respirator usage in coke oven workers . AIHA J. , 63 : 72 – 75 . (short communication)

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.