823
Views
15
CrossRef citations to date
0
Altmetric
Original Articles

Evaluation of a Wearable Physiological Status Monitor During Simulated Fire Fighting Activities

, , , &

REFERENCES

  • National Fire Protection Association: Firefighter Fatalities in the United States -2012, by R.F. Fahy, P.R. LeBlanc, and J.L. Molis. Quincy, Mass.: National Fire Protection Association, 2013.
  • Barnard, R.J., and H.W. Duncan: Heart rate and ECG responses of fire fighters. J. Occup. Med. 17(4):247–250 (1975).
  • Gledhill, N., and V.K. Jamnik: Characterization of the physical demands of firefighting. Can. J. Sport Sci. 17(3):207–213 (1992).
  • Holmer, I., and D. Gavhed: Classification of metabolic and respiratory demands in fire fighting activity with extreme workloads. Appl. Ergonomics. 38(1):45–52 (2007).
  • Lemon, P.W., and R.T. Hermiston: The human energy cost of fire fighting. J. Occup. Med. 19(8):558–562 (1977).
  • Smith, D.L., T.S. Manning, and S.J. Petruzzello: Effect of strenuous live-fire drills on cardiovascular and psychological responses of recruit firefighters. Ergonomics 44(3):244–254 (2001).
  • Brouha, L., M.E. Maxfield, P.E. Smith, Jr., and G.J. Stopps: Discrepancy between heart rate and oxygen consumption during work in the warmth. J. Appl. Physiol. 18:1095–1098 (1963).
  • Maxfield, M.E., and L. Brouha: Validity of heart rate as an indicator of cardiac strain. J. Appl. Physiol. 18:1099–1104 (1963).
  • Hailstone, J., and A.E. Kilding: Reliability and validity of the Zephyr BioHarness to measure respiratory responses to exercise. Meas. Phys. Educ. Exerc. Sci. 15(4):293–300 (2011).
  • Kent, L., B. O’Neill, G. Davison, A. Nevill, J.S. Elborn, and J.M. Bradley: Validity and reliability of cardiorespiratory measurements recorded by the LifeShirt during exercise tests. Respir. Physiol. Neurobiol. 167(2):162–167 (2009).
  • Kim, J.H., R. Roberge, J.B. Powell, A.B. Shafer, and W.J. Williams: Measurement accuracy of heart rate and respiratory rate during graded exercise and sustained exercise in the heat using the Zephyr BioHarnessT. Int. J. Sports Med. 34(6):497–501 (2013).
  • Coca, A., R.J. Roberge, W.J. Williams, D.P. Landsittel, J.B. Powell, and A. Palmiero: Physiological monitoring in firefighter ensembles: Wearable plethysmographic sensor vest versus standard equipment. J. Occup. Environ. Hyg. 7(2):109–114 (2010).
  • Rosdahl, H., L. Gullstrand, J. Salier-Eriksson, P. Johansson, and P. Schantz: Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method. Eur. J. Appl. Physiol. 109(2):159–171 (2010).
  • Bruce, R.A., F. Kusumi, and D. Hosmer: Maximal oxygen intake and nomographic assessment of functional aerobic impairment in cardiovascular disease. Am. Heart J. 85(4):546–556 (1973).
  • Bland, J.M., and D.G. Altman: Measuring agreement in method comparison studies. Stat. Methods Med. Res. 8(2):135–160 (1999).
  • Bland, J.M., and D.G. Altman: Agreement between methods of measurement with multiple observations per individual. J. Biopharm. Stat. 17(4):571–582 (2007).
  • Leger, L., and M. Thivierge: Heart rate monitors: validity, stability, and functionality. Physician Sportsmed. 16(5):143–146,148149, 151 (1988).
  • Terbizan, D.J., B.A. Dolezal, and C. Albano: Validity of seven commercially available heart rate monitors. Meas. Phys. Educ. Exerc. Sci. 6(4):243–247 (2002).
  • Johnstone, J.A., P.A. Ford, G. Hughes, T. Watson, A.C.S. Mitchell, and A.T. Garrett: Field based reliability and validity of the Bioharness multivariable monitoring device. J. Sports Sci. Med. 11:643–652 (2012).
  • Johnstone, J.A., P.A. Ford, G. Hughes, T. Watson, and A.T. Garrett: Bioharness multivariable monitoring device. Part I: Validity. J. Sports Sci. Med. 11(3):400–408 (2012).
  • Heilman, K.J., and S.W. Porges: Accuracy of the LifeShirt (Vivometrics) in the detection of cardiac rhythms. Biol. Psychol. 75(3):300–305 (2007).
  • Liu, Y., S.H. Zhu, G.H. Wang, F. Ye, and P.Z. Li: Validity and reliability of multiparameter physiological measurements recorded by the Equivital LifeMonitor during activities of various intensities. J. Occup. Environ. Hyg. 10(2):78–85 (2013).
  • U.S. Army Research Institute of Environmental Medicine: Hidalgo Equivital Physiological Monitor Product Review and Data Summary, by J.S. Cuddy, B.C. Ruby, W.R. Santee, and A.J. Karis (USARIEM Technical Report T09-02). . Natick, MA: US Army Research Institute of Environmental Medicine, December 2008.
  • U.S. Army Research Institute of Environmental Medicine: Demonstration of Real-time Physiological Status Monitoring of Encapsulated 1st Civil Support Team - Weapons of Mass Destruction (CST-WMD) Personnel, by J.B. Buller, W.J. Tharion, A.J. Karis, et al. . (USARIEM Technical Report T08-01). . Natick, MA: US Army Research Institute of Environmental Medicine, October 2007.
  • Bianchi, W., A.F. Dugas, Y.-H. Hsieh, et al.: Revitalizing a vital sign: Improving detection of tachypnea at primary triage. Ann. Emerg. Med. 61(1):37–43 (2013).
  • Celli, B.R., J. Rassulo, and B.J. Make: Dyssynchronous breathing during arm but not leg exercise in patients with chronic airflow obstruction. N. Eng. J. Med. 314(23):1485–1490 (1986).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.