An intelligent FFR with a self-adjustable ventilation fan

, ORCID Icon, , , , & show all

References

  • Kim, J.H., R.J. Roberge, J.B. Powell, R.E. Shaffer, C.M. Ylitalo, and J.M. Sebastian: Pressure drop of filtering facepiece respirators: How low should we go?. Int. J Occup. Med Env. 28(1):0–0 (2014).
  • Zhang, X., H. Li, S. Shen, and M. Cai: Investigation of the flow-field in the upper respiratory system when wearing N95 filtering facepiece respirator. J. Occup. Environ. Hyg. 13(5):372–382 (2016).
  • Lee, H.P., and D.Y. Wang: Objective assessment of increase in breathing resistance of N95 respirators on human subjects. Ann. Occup.Hyg. mer065 (2011).
  • Roberge, R.J., J.H. Kim, and S. Benson: N95 filtering facepiece respirator deadspace temperature and humidity. J. Occup. Environ. Hyg. 9(3):166–171 (2012).
  • Roberge, R., S. Benson, and J.H. Kim: Thermal burden of N95 filtering facepiece respirators. Ann. Occup. Hyg. mes001 (2011).
  • Roberge, R.J.: Are exhalation valves on N95 filtering facepiece respirators beneficial at low-moderate work rates: an overview. J. Occup. Environ. Hyg. 9(11):617–623 (2012).
  • Zhang, X., H. Li, S. Shen, Y. Rao, and F. Chen: An improved FFR design with a ventilation fan: CFD simulation and validation. PloS One 11(7):e0159848 (2016).
  • Birgersson, E., E.H. Tang, W.L.J. Lee, and K.J. Sak: Reduction of carbon dioxide in filtering facepiece respirators with an active-venting system: a computational study. PloS One 10(6):e0130306 (2015).
  • Matsunaga, N., T. Shiotsuki, H. Okajima, N. Ohmura, and H. Teramura: Experiment of measurement and control using embedded system for undergraduate students. IFAC Proc. Vol. 42(24):77–82 (2010).
  • Chattopadhyay, M., and D. Chowdhury: A new scheme for reducing breathing trouble through MEMS based capacitive pressure sensor. Microsyst. Technol. 1–6 (2015).
  • Roberge, R.J., E. Bayer, J.B. Powell, A. Coca, M.R. Roberge, and S.M. Benson: Effect of exhaled moisture on breathing resistance of N95 filtering facepiece respirators. Ann. Occup. Hyg. meq042 (2010).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.