References
- ACGIH. 2019. Industrial ventilation: a manual for recommended practice for design. Cincinnati (OH): ACGIH.
- ACGIH. 2021. Industrial Ventilation Committee. Ventilation for industrial settings during the COVID-19 pandemic. Cincinnati (OH): ACGIH; [accessed 2021 Dec 16]. https://1lnfej4c7wie44voctzq1r57-wpengine.netdna-ssl.com/wp-content/uploads/2021/07/ASHRAE-ACGIH-COVID-19-White-Paper_2021-07-26.pdf.
- ASHRAE. 2004. ASHRAE standard: ventilation for acceptable indoor air quality. Atlanta (GA): American Society of Heating, Refrigerating and Air-Conditioning Engineers. Report No: ANSI/ASHRAE Standard 62.1-2004.
- ASHRAE. 2020. Epidemic task force: schools & universities. Atlanta (GA): American Society of Heating, Refrigerating and Air-Conditioning Engineers; [accessed 2020 Jul 20]. https://www.ashrae.org/file%20library/technical%20resources/covid-19/ashrae-reopening-schools-and-universities-c19-guidance.pdf.
- Burgess WA, Ellenbecker MJ, Treitman RD. 2004. Ventilation for control of the work environment. Hoboken (NJ): John Wiley & Sons.
- Escombe AR. 2006. The detection and prevention of airborne tuberculosis transmission. Clin Infect Dis. 44(10):1349–1357.
- Greenhalgh T, Jimenez JL, Prather KA, Tufekci Z, Fisman D, Schooley R. 2021. Ten scientific reasons in support of airborne transmission of SARS-CoV-2. Lancet. 397(10285):1603–1605. doi:10.1016/S0140-6736(21)00869-2
- Hosseini MR, Fouladi-Fard R, Aali R. 2020. COVID-19 pandemic and sick building syndrome. Indoor Built Environ. 29(8):1181–1183. doi:10.1177/1420326X20935644
- IFC 2015. International Fire Code (IFC). (USA): International Code Council, Inc; [accessed 2021 Apr 19]. https://codes.iccsafe.org/content/IFC2015/chapter-10-means-of-egress#IFC2015_Pt03_Ch10_Sec1002.
- Kucharski A, Klepac P, Conlan A, Kissler S, Tang M, Fry H, Gog J, Edmunds J, Emery J, Medley G, et al. 2020. Effectiveness of isolation, testing, contact tracing, and physical distancing on reducing transmission of SARS-CoV-2 in different settings: a mathematical modelling study. Lancet Infect Dis. 20(10):1151–1160. doi:10.1016/S1473-3099(20)30457-6
- Mundhe P, Damle RM, Vaidya P. 2019. Evaluation of ventilation metrics for naturally ventilated spaces from flow patterns generated in a water table apparatus. Paper presented at the 16th IBPSA Conference, Rome, Italy, September 2–4, 2019.
- NFPA. 2011. Table 7.3.1.2 occupant load factor. Data from: NFPA 101: Life Safety Code; [accessed 2021 Mar 7]. https://totalforcevlc.golearnportal.org/Fire_Inspector_II/Occupant_Load_Factor_Table.pdf.
- Persily A, Dols WS. 1990. The relation of CO2 concentration to office building ventilation. Air change rate and airtightness in buildings. West Conshohocken (PA): ASTM International.
- Qian H, Zheng X. 2018. Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings. J Thorac Dis. 10(Suppl 19):S2295–S2304. doi:10.21037/jtd.2018.01.24
- Scheff PA, Paulius VK, Huang SW, Conroy LM. 2000. Indoor air quality in a middle school, part I: use of CO2 as a tracer for effective ventilation. Appl Occup Environ Hyg. 15(11):824–834. doi:10.1080/10473220050175706
- TSI. 2022. Percent outdoor air (%OA) calculation and its use; [accessed 2022 Feb 15]. https://tsi.com/getmedia/5e5e04c6-f29d-4a92-80f6-2287f97c29db/Percent-Outdoor-Air-App-Note-(TI-138)-US.