96
Views
0
CrossRef citations to date
0
Altmetric
Research Article

Analysis of thermal performance characteristics in variable header solar water heating system by a swirling effect of twisted tapes

&
Pages 10630-10646 | Received 21 Dec 2018, Accepted 05 May 2020, Published online: 27 Jul 2020

References

  • Ananth, J., and S. Jaisankar. 2013. Experimental studies on heat transfer and friction factor characteristics of thermosyphon solar water heater system fitted with regularly spaced twisted tape with rod and spacer. Energy Conversion and Management 73:207–13. doi:10.1016/j.enconman.2010.11.024.
  • Aung, N. Z., and L. Songjing. 2013. Numerical investigation on effect of riser diameter and inclination on system parameters in a two-phase closed loop thermosyphon solar water heater”. Energy Conversion and Management 75:25–35. doi:10.1016/j.enconman.2013.06.001.
  • Bello, M. B., and A. S. Sambo. 1992. Simulation studies on pipe spacings for a collector and tank size for solar water heater. Energy Conversion Management 33 (3):215–23. doi:10.1016/0196-8904(92)90128-J.
  • Bhuiya, M. M. K., M. S. U. Chowdhury, M. Saha, and M. T. Islam. 2012. Heat transfer and friction factor characteristics in turbulent flow through a tube fitted with perforated twisted tape inserts. International Communications in Heat and Mass Transfer 46 (4):49–57. doi:10.1016/j.icheatmasstransfer.2013.05.012.
  • Bovand, M., S. Rashidi, and J. A. Esfahani. 2016. Heat transfer enhancement and pressure drop penalty in porous solar heaters numerical simulations. Solar Energy 123:145–49. doi:10.1016/j.solener.2015.10.054.
  • Close, D. J. 1962. The performance of solar water heaters with natural circulation. Solar Energy 6 (1):33–40. doi:10.1016/0038-092X(62)90096-8.
  • Coleman, H. W., and W. G. Steele. 1989. Experimental and uncertainty analysis for engineers. Vol. 19. 1–1985. New York: Wiley, PTC. ANSI/ASME.1986. Measurement uncertainty,
  • Duffie, J. A., and W. A. Beckman. 1980. Solar engineering of thermal process. 4th ed. New York: Wiley Interscience.
  • Gandhi, M. S., A. A. Ganguli, J. B. Joshia, and P. K. Vijayan. 2012. CFD simulation for steam distribution in header and tube assemblies. Chemical Engineering Research and Design 90 (4):487–506. doi:10.1016/j.cherd.2011.08.019.
  • Hahne, E. 1985. Parameter effects on design and performance of flat plate solar collectors. Solar Energy 34 (6):497–504. doi:10.1016/0038-092X(85)90023-4.
  • Hutchins, M. G. 1979. Spectrally selective solar absorber coatings. Applied Energy 5 (4):251–62. doi:10.1016/0306-2619(79)90016-3.
  • Jaisankar., S., T. K. Radhakrishnan, and K. N. Sheeba. 2009. Experimental studies on heat transfer and friction factor characteristics of thermosyphon solar water heater system fitted with spacer at the trailing edge of twisted tapes. Applied Thermal Engineering 29 (5–6):1224–31. doi:10.1016/j.applthermaleng.2008.06.009.
  • Jaisankar., S., T. K. Radhakrishnan, and K. N. Sheeba. 2011. Experimental studies on heat transfer and thermal performance Solar water system with helical and Left-right twisted tapes. Energy Conversion Management 52 (5):2048–55. doi:10.1016/j.enconman.2010.11.024.
  • JianGuo, A., X. Z. Fan, W. Liu, and W. Liu. 2011. A numerical study on heat transfer and friction factor characteristics of laminar flow in a circular tube fitted with center-cleared twisted tape. International Journal of Thermal Sciences 50 (7):1263–70. doi:10.1016/j.ijthermalsci.2011.02.010.
  • Krishna, S. R., G. Pathipaka, and P. Sivashanmugam. 2009. Heat transfer and pressure drop studies in a circular tube fitted with straight full twist. Experimental Thermal and Fluid Science 33 (3):431–38. doi:10.1016/j.expthermflusci.2008.10.007.
  • Kumar ., A., and B. N. Prasad. 2000. Investigation of twisted tape inserted solar water heaters,heat transfer, friction factor and thermal performance results”. Renewable Energy 19 (3):379–98. doi:10.1016/S0960-1481(99)00061-0.
  • Liao, Q., and M. D. Xin. 2000. Augmentation of convective heat transfer inside tubes with three-dimensional internal extended surfaces and twisted-tape inserts. Chemical Engineering Journal 78 (2–3):95–105. doi:10.1016/S1385-8947(00)00134-0.
  • Marchitto, A., M. Fossa, and G. Guglielmini. 2016. Phase split in parallel vertical channels in presence of a variable depth protrusion header. Experimental Thermal and Fluid Science 74:257–64. doi:10.1016/j.expthermflusci.2015.12.017.
  • Morrison, G. L., and D. B. J. Ranatunga. 1980. thermosyphon circulation in solar collectors. Solar Energy 24 (2):191–98. doi:10.1016/0038-092X(80)90392-8.
  • Murugesan, P., K. Mayilsamy, and S. Suresh. 2010. Turbulent heat transfer and pressure drop in tube fitted with square-cut twisted tape. Chinese Journal of Chemical Engineering 18 (4):609–17. doi:10.1016/S1004-9541(10)60264-9.
  • Murugesan., P., K. Mayilsamy, S. Suresh, and P. S. S. Srinivasan. 2011. Heat transfer and pressure drop characteristics in a circular tube fitted with and without V-cut twisted tape insert. International Communications in Heat and Mass Transfer 38 (3):329–34. doi:10.1016/j.icheatmasstransfer.2010.11.010.
  • Nanan, K., K. Wongcharee, C. Nuntadusit, and S. Eiamsa-ard. 2012. Forced convective heat transfer by swirling impinging jets issuing from nozzles equipped with twisted tapes. International Communications in Heat and Mass Transfer 39 (6):844–52. doi:10.1016/j.icheatmasstransfer.2012.05.002.
  • Saravanan, A., J. S. Senthilkumaar, and S. Jaisankar. 2016. Performance assessment in V-trough solar water heater fitted with square and V-cut twisted tape inserts. Applied Thermal Engineering 102:476–86. doi:10.1016/j.applthermaleng.2016.03.088.
  • Sheikholeslami, M., and D. D. Ganjii. 2016. Heat transfer enhancement in an air to water heat exchanger with discontinuous helical turbulators; experimental and numerical studies. Energy 116 (1):341–52. doi:10.1016/j.energy.2016.09.120.
  • Sieder, E. N., and G. E. Tate. 1936. Heat transfer and pressure drop of liquids in tubes. Industrial and Engineering Chemistry 28 (12):1429–39. doi:10.1021/ie50324a027.
  • Thulasi, S., and S. Jai Sankar. 2016. Performance analysis of conventional and variable header thermosyphon solar water heating system. Asian Journal of Research in Social Sciences and Humanities 6 (10):1807–23. doi:10.5958/2249-7315.2016.01131.X.
  • Usui, H., Y. Sano, K. Iwashita, and A. Isozaki. 1996. Enhancement of heat transfer by a combination of internally grooved rough tube and twisted tape. International Chemical Engineering 26 (1):97–104.
  • Vashistha, C., A. K. Patil, and M. Kumar. 2016. Experimental investigation of heat transfer and pressure drop in a circular tube with multiple inserts. Applied Thermal Engineering 96:117–29. doi:10.1016/j.applthermaleng.2015.11.077.
  • wang, C.-C., K.-S. Yang, J.-S. Tsai, and Y. chen. 2011. Characteristics of floor distribution in compact parallel flow heat exchangers part II: Modified inlet header. Applied Thermal Engineering 31 (16):3235–42. doi:10.1016/j.applthermaleng.2011.06.003.
  • whiller, A., and G. Saluja. 1965. Effect of materials and constructive details on the thermal performance of solar water heaters. Solar Energy 9 (1):21–26. doi:10.1016/0038-092X(65)90156-8.
  • Wongcharee, K., and S. Eiamsa-ard. 2011. Friction and heat transfer characteristics of laminar swirl flow through the round tubes inserted with alternate clockwise and counter-clockwise twisted-tapes. International Communications in Heat and Mass Transfer 38 (3):348–52. doi:10.1016/j.icheatmasstransfer.2010.12.007.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.