References
- Kemp D T. Stimulated acoustic emission from the human auditory system. J Acoust Soc Am 1978; 64: 1386–91
- Mulheran M, Degg C. Comparison of distortion product OAE generation between a patient group requiring frequent gentamycin therapy and control subjects. Br J Audiol 1997; 31: 5–9
- Sockalingam R, Murdoch B, Filippich L, Charles B. The cumulative effect of cisplatin on auditory brainstem responses and otoacoustic emissions in a dog: an experimental case study. J Audiol Med 2000; 9: 80–93
- Oeken I, Müller H. Distortion product otoacoustic emissions (DPOAE) in chronic noise-induced hearing loss: recommendations for expert assessment. Laryngorhinootologie 1995; 74: 473–80
- Plinkert P K, de Maddalena H. Recording otoacoustic emissions in expert evaluation of chronic noise-induced hearing loss. HNO 1996; 44: 313–8
- Gorga M P, Neely S T, Bergman B M, Beauchaine K L, Kaminski J R, Peters J, et al. A comparison of transient evoked and distortion product otoacoustic emissions in normal-hearing and hearing-impaired subjects. J Acoust Soc Am 1993; 94: 2639–48
- Harris R, Probst R. Otoacoustic emissions and audiometric outcomes, M S Robinette, T J Glattke. Thieme, New York 1997; 151–80, Otoacoustic emissions: clinical applications
- Franklin D J, McCoy M J, Martin G K, Lonsbury-Martin B L. Test/re-test reliability of distortion product and transiently evoked otoacoustic emissions. Ear Hear 1992; 13: 417–29
- Chan R H, McPherson B. Test-retest reliability of tone-burst-evoked otoacoustic emissions. Acta Otolaryngol 2000; 120: 825–34
- Beattie R C, Bleech J. Effects of sample size on the reliability of noise floor and DPOAE. Br J Audiol 2000; 34: 305–9
- Beattie R C, Kenworthy O T, Luna C A. Immediate and short-term reliability of distortion product otoacoustic emissions. Int J Audiol 2003; 42: 348–54
- Hornsby B, Kelly T, Hall J W. Normative data for five FDA approved distortion product OAE systems. Hearing J 1996; 49(9): 39–46
- Martin G K, Ohlms L A, Franklin D J, Harris F P, Lonsbury-Martin B L. Distortion product emissions in humans: III. Influence of sensorineural hearing loss. Ann Otol Rhinol Laryngol Suppl 1990; 147: 30–42
- Marshall L, Heller L M. Reliability of transient-evoked otoacoustic emissions. Ear Hear 1996; 17: 237–54
- American National Standards Institute. Specifications for audiometers, S3.6. American National Standards Institute, New York 1969
- Kemp D T, Ryan S, Bray P. A guide to the effective use of otoacoustic emissions. Ear Hear 1990; 11: 93–105
- Feise R J. Do multiple outcome measures require p-value adjustment. BMC Medical Research Methodology 2002; 2: 8
- Rafitis I, Cummiskey C, Herer G, Glattke T J. Detection of hearing loss using otoacoustic emissions. Institute of Noise Control Engineering, Japan & Acoustical Society of Japan, Osaka 1994; 763–8, In: Proceedings of Internoise 94
- Prieve B A, Fitzgerald T S, Schulte L E. Basic characteristics of click-evoked otoacoustic emissions in infants and children. J Acoust Soc Am 1997; 102: 2860–70
- Siegel J H, Hirohata E T. Sound calibration and distortion product otoacoustic emissions at high frequencies. Hear Res 1994; 80: 146–52