- Adalberth G, Nilsson K G, Byström S, Kolstad K, Milbrink J. Low-conforming all-polyethylene tibial component not inferior to metal-backed component in cemented total knee arthroplasty: prospective, randomized radiostereometric analysis study of the AGC total knee prosthesis. J Arthroplasty 2000; 15(6): 783–92.
- Adalberth G, Nilsson KG, Byström S, Kolstad K, Milbrink J. All-polyethylene versus metal-backed and stemmed tibial components in cemented total knee arthroplasty. A prospective, randomised RSA study. J Bone Joint Surg Br 2001; 83(6): 825–31.
- Adalberth G, Nilsson K G, Kärrholm J, Hassander H. Fixation of the tibial component using CMW-1 or Palacos bone cement with gentamicin: similar outcome in a randomized radiostereometric study of 51 total knee arthroplasties. Acta Orthop Scand 2002; 73(5): 531–8.
- Aspenberg P, Wagner P, Nilsson K G, Ranstam J. Fixed or loose? Dichotomy in RSA data for cemented cups. Acta Orthop 2008; 79(4): 467–73.
- Carlsson A, Björkman A, Besjakov J, Önsten I. Cemented tibial component fixation performs better than cementless fixation. Acta Orthop 2005; 76(3): 362–9.
- Grewal R, Rimmer M G, Freeman F A R. Early migration of prostheses related to long-term survivorship. Comparison of tibial components in knee replacement. J Bone Joint Surg (Br) 1992; 74: 239–42.
- Hauptfleisch J, Glyn-Jones S, Beard D J, Gill H S, Murray D W. The premature failure of the Charnley Elite-Plus stem. J Bone Joint Sur (Br) 2006; 88-B: 179–83.
- Henricson A, Linder L, Nilsson KG. A trabecular metal tibial component in total knee replacement in patients younger than 60 years. A two-year radiostereophotogrammetric analysis. J Bone Joint Surg (Br) 2008; 90: 1585–93.
- Henricson A, Rösmark D, Nilsson K G. Trabecular metal tibia still stable at 5 years. Acta Orthop 2013; 84 (4): 398–405.
- Nelissen R G, Valstar E R, Rozing P M. The effect of hydroxyapatite on the micromotion of total knee prostheses. A prospective, randomized, double-blind study. J Bone Joint Surg (Am) 1998; 80 (11): 1665–72.
- Nieuwenhuijse M J. Good diagnostic performance of early migration as a predictor of late aseptic loosening of acetabular cups. J Bone Joint Surg (Am) 2012; 94: 874–80.
- Nilsson K G, Kärrholm J. Increased varus-valgus tilting of screw-fixated knee prostheses. Stereoradiographic study of uncemented versus cemented tibial components. J Arthroplasty 1993; 8:529–40.
- Nilsson K G, Kärrholm J, Carlsson L, Dalén T. Hydroxyapatite coating versus cemented fixation of tibial component in total knee arthroplasty. Prospective randomized comparisation of hydroxyapatite-coated and cemented tibial components with 5-Year follow-up using radiostereometri (RSA). J Arthroplasty 1999; 14(1): 9–20.
- Nilsson K G, Kärrholm J, Linder L. Femoral component migration in total knee arthroplasty: randomized study comparing cemented and uncemented fixation of the Miller-Galante 1 design. J Orthop Res 1995; 13: 347–56.
- Nilsson K G, Henricson A, Dalen T. In vivo determination of modular tibial insert micromotion. Trans Orthop Res Soc. 2003; 28: 1402.
- Nilsson K G, Henricson A, Norgren B, Dalén T. Uncemented HA-coated implant is the optimum fixation for TKA in the young patient. Clin Orthop Relat Res 2006; 448: 129–39.
- Pijls B G, Nieuwenhuijse M J, Fiocco M, Plevier J W M, Middeldorp S, Nelissen R G, Valstar E R. Early proximal migration of cups is associated with late revision in THA. Acta Orthop 2012a; 83(2): 135–41.
- Pijls B G, Valstar E R, Nouta K A, Plevier J W M, Fiocco M, Middeldorp S, Nelissen R G. Early migration of tibial components is associated with late revision. Acta Orthop 2012b; 83(6): 614–24.
- R Development Core Team. A language and environment for statistical computing. 2012. http://www.R-project.org/
- Rao A R, Engh G A, Collier M B, Lounici S. Tibial interface wear in retrieved total knee components and correlations with modular insert motion. J Bone Joint Surg Am 2002; 84-A(10): 1849–55.
- Ryd L. Micromotion in knee arthroplasty: a roentgen stereophotogrammetric analysis of tibial component fixation. Acta Orthop Scand 1986; Suppl 220: 1–60
- Ryd L, Albrektsson B, Carlsson L, Dansgard F, Herberts P, Lindstrand A, Regner L, Toksvig-Larsen S. Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses. J Bone Surg (Br) 1995; 77-B(3): 377–83.
- Valstar E R, Gill R, Ryd L, Flivik G, Börlin N, Kärrholm J. Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop 2005; 76(4): 563–72.
Acta Orthopaedica
Volume 88, 2017 - Issue 3
Open access
1,295
Views
26
CrossRef citations to date
0
Altmetric
Original Articles
Tibial component rotation around the transverse axis measured by radiostereometry predicts aseptic loosening better than maximal total point motion
A follow-up of 116 total knee arthroplasties after at least 15 years
Asgeir GudnasonDepartment of Orthopedics, Institute of Surgical Sciences, Uppsala University Hospital, Uppsala; Correspondence[email protected]
, Gunnar AdalberthDepartment of Orthopedics, Institute of Surgical Sciences, Uppsala University Hospital, Uppsala;
, Kjell-Gunnar NilssonDepartment of Surgical and Perioperative Sciences, University of Umeå, Umeå, Sweden
& Nils P HailerDepartment of Orthopedics, Institute of Surgical Sciences, Uppsala University Hospital, Uppsala;
Pages 282-287
|
Received 23 Oct 2015, Accepted 29 Nov 2016, Published online: 07 Mar 2017
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.