856
Views
2
CrossRef citations to date
0
Altmetric
Articles

New 3-dimensional implant application as an alternative to allograft in limb salvage surgery: a technical note on 10 cases

, &

  • Agarwal M, Puri A, Gulia A, Reddy K. Joint-sparing or physeal-sparing diaphyseal resections: The challenge of holding small fragments. Clin Orthop Rel Res 2010; 468(11): 2924–32.
  • Bobyn J, Pilliar R, Cameron H, Weatherly G. The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone. Clin Orthop Rel Res 1980; (150): 263–70.
  • Chen W-M, Xie Y M, Imbalzano G, Shen J, Xu S, Lee S-J, et al. Lattice Ti structures with low rigidity but compatible mechanical strength: Design of implant materials for trabecular bone. International Journal of Precision Engineering and Manufacturing 2016; 17(6): 793–9.
  • Gerrand C H, Griffin A M, Davis A M, Gross A E, Bell R S, Wunder J S. Large segment allograft survival is improved with intramedullary cement. J Surg Oncol 2003; 84(4): 198–208.
  • Guyer R D, Abitbol J J, Ohnmeiss D D, Yao C. Evaluating osseointegration into a deeply porous titanium scaffold: a biomechanical comparison with PEEK and allograft. Spine 2016; 41(19): E1146–1150.
  • Huang H-C, Hu Y-C, Lun D-X, Miao J, Wang F, Yang X-G, et al. Outcomes of intercalary prosthetic reconstruction for pathological diaphyseal femoral fractures secondary to metastatic tumors. Orthop Surg 2017; 9(2): 221–8.
  • Jenkins D R, Odland A N, Sierra R J, Hanssen A D, Lewallen D G. Minimum five-year outcomes with porous tantalum acetabular cup and augment construct in complex revision total hip arthroplasty. J Bone Joint Surg 2017; 99(10): e49.
  • Mankin H J, Hornicek F J, Temple H T, Gebhardt M C. (2004). Malignant tumors of the pelvis: an outcome study. Clin Orthop Rel Res 2004; 425: 212–7.
  • McGilvray K C, Easley J, Seim H B, Regan D, Berven S H, Hsu W K, Mroz T E, Puttlitz C M. Bony ingrowth potential of 3D-printed porous titanium alloy: a direct comparison of interbody cage materials in an in vivo ovine lumbar fusion model. Spine J 2018; 18(7): 1250–60.
  • Moharrami N, Langton DJ, Sayginer O, Bull S J. Why does titanium alloy wear cobalt chrome alloy despite lower bulk hardness: A nanoindentation study? Thin Solid Films 2013; 549: 79–86.
  • Mumith A, Coathup M, Chimutengwende-Gordon M, Aston W, Briggs T, Blunn G. Augmenting the osseointegration of endoprostheses using laser-sintered porous collars: an in vivo study. Bone Joint J 2017; 99-B(2): 276–82.
  • Park J W, Kang H G, Kim J H, Kim H-S. New 3-dimensional implant application as an alternative to allograft in limb salvage surgery: A technical note on 10 cases. Acta Orthop 2020a May; doi.org/10.1080/17453674.2020.1755543 [Ahead of print]
  • Park J W, Song C A, Kang H G, Kim J H, Lim K M, Kim H-S. Integration of a three-dimensional-printed titanium implant in human tissues: case study. Applied Sciences 2020b; 10(2): 553.
  • Puri A, Byregowda S, Gulia A, Patil V, Crasto S, Laskar S. Reconstructing diaphyseal tumors using radiated (50 Gy) autogenous tumor bone graft. J Surg Oncol 2018; 118(1): 138–43.
  • Wu S H, Li Y, Zhang Y Q, Li X K, Yuan C F, Hao Y L, et al. Porous titanium-6 aluminum-4 vanadium cage has better osseointegration and less micromotion than a poly-ether-ether-ketone cage in sheep vertebral fusion. Artif Organs 2013: 37(12), E191–201.