- Callary S A, Solomon L B, Holubowycz O T, Campbell D G, Munn Z, Howie D W. Wear of highly crosslinked polyethylene acetabular components. Acta Orthop 2015; 86(2): 159–68.
- Devane P A, Horne J G, Ashmore A, Mutimer J, Kim W, Stanley J. Highly cross-linked polyethylene reduces wear and revision rates in total hip arthroplasty. J Bone Joint Surg 2017; 99(20): 1703–14.
- Dorr L D, Wan Z, Shahrdar C, Sirianni L, Boutary M, Yun A. Clinical performance of a Durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years. J Bone Joint Surg 2005; 87(8): 1816.
- Dumbleton J H, Manley M T, Edidin A A. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 2002; 17(5): 649–61.
- Galea V P, Connelly J W, Shareghi B, Kärrholm J, Sköldenberg O, Salemyr M, Laursen M B, Muratoglu O, Bragdon C, Malchau H. Evaluation of in vivo wear of vitamin E-diffused highly crosslinked polyethylene at five years. Bone Joint J 2018; 100-B(12): 1592–9.
- Geerdink C H, Grimm B, Vencken W, Heyligers I C, Tonino A. The determination of linear and angular penetration of the femoral head into the acetabular component as an assessment of wear in total hip replacement: a comparison of four computer-assisted methods. J Bone Joint Surg Br 2008; 90(7): 839–46.
- Gwynne-Jones D P, Garneti N, Wainwright C, Matheson J A, King R. The Morscher press fit acetabular component: a nine- to 13-year review. J Bone Joint Surg Br 2009; 91(7): 859–64.
- Halma J J, Eshuis R, Vogely H C, van Gaalen S M, de Gast A. An uncemented iso-elastic monoblock acetabular component: preliminary results. J Arthroplasty 2015; 30(4): 615–21.
- Harris W H. Wear and periprosthetic osteolysis: the problem. Clin Orthop Relat Res 2001; (393): 66–70.
- Knahr K, editor. Total hip arthroplasty: wear behaviour of different articulations. Heidelberg/Vienna: Springer; 2012.
- Kurtz S M, Gawel H A, Patel J D. History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene. Clin Orthop Relat Res 2011; 469(8): 2262–77.
- Lachiewicz P F, Heckman D S, Soileau E S, Mangla J, Martell J M. Femoral head size and wear of highly cross-linked polyethylene at 5 to 8 years. Clin Orthop Relat Res 2009; 467(12): 3290–6.
- Lachiewicz P F, Soileau E S, Martell J M. Wear and osteolysis of highly crosslinked polyethylene at 10 to 14 years: the effect of femoral head size. Clin Orthop Relat Res 2016; 474(2): 365–71.
- Lambert B, Neut D, van der Veen H C, Bulstra S K. Effects of vitamin E incorporation in polyethylene on oxidative degradation, wear rates, immune response, and infections in total joint arthroplasty: a review of the current literature. Int Orthop 2018; 43(7): 1549–57.
- Lawrie D, Downing M, Patrick Ashcroft G, Gibson P. Insertion of tantalum beads in RSA of the hip: variations in incidence of extra-osseous beads with insertion site. Acta Orthop 2003; 74(4): 404–7.
- Martell J M, Berkson E, Berger R, Jacobs J. Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty. J Bone Joint Surgery Am 2003; 85(6): 1111–17.
- McCalden R W, Naudie D D, Yuan X, Bourne R B. Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am 2005; 87(10): 2323–34.
- Muratoglu O K, Bragdon C R, O’Connor D, Perinchief R S, Estok D M, Jasty M, Harris W H. Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: a new concept. J Arthroplasty 2001; 16(8 Suppl. 1): 24–30.
- Nebergall A, Greene M E, Laursen M B, Nielsen P T, Malchau H, Troelsen A. Vitamin E diffused highly cross-linked polyethylene in total hip arthroplasty at five years: a randomised controlled trial using radiostereometric analysis. Bone Joint J 2017; 99-B(5): 577–84.
- Oral E, Wannomae K K, Hawkins N, Harris W H W H, Muratoglu O K O K. Alpha-tocopherol-doped irradiated UHMWPE for high fatigue resistance and low wear. Biomaterials 2004; 25(24): 5515–22.
- Oral E, Christensen S D, Malhi A S, Wannomae K K, Muratoglu O K. Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E. J Arthroplasty 2006; 21(4): 580–91.
- Pakvis D, Biemond L, Van Hellemondt G, Spruit M. A cementless elastic monoblock socket in young patients: a ten to 18-year clinical and radiological follow-up. Int Orthop 2011; 35(10): 1445–51.
- Rochcongar G, Buia G, Bourroux E, Dunet J, Chapus V, Hulet C. Creep and wear in vitamin e-infused highly cross-linked polyethylene cups for total hip arthroplasty. J Bone Joint Surg Am 2018; 100(2): 107–14.
- Scemama C, Anract P, Dumaine V, Babinet A, Courpied J P, Hamadouche M. Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial. Int Orthop 2017; 41(6): 1113–18.
- Shareghi B, Johanson P-E, Kärrholm J. Wear of vitamin E-infused highly cross-linked polyethylene at five years. J Bone Joint Surg Am 2017; 99(17): 1447–52.
- Snijders T E, Halma J J, Massier J R A, van Gaalen S M, de Gast A. The survivorship of the uncemented iso-elastic monoblock acetabular component at a mean of 6-year follow-up. HSS J 2019; 16(1): 15–22.
- Sutula L C, Collier J P, Saum K A, Currier B H, Currier J H, Sanford W M, Mayor M B, Wooding R E, Sperling D K, Williams I R. The Otto Aufranc Award: Impact of gamma sterilization on clinical performance of polyethylene in the hip. Clin Orthop Relat Res 1995; (319): 28–40.
- Sychterz C J, Engh C A J, Yang A, Engh C A. Analysis of temporal wear patterns of porous-coated acetabular components: distinguishing between true wear and so-called bedding-in. J Bone Joint Surg Am 1999; 81(6): 821–30.
- van Erp J H J, Massier J R A, Halma J J, Snijders T E, de Gast A. 2-year results of an RCT of 2 uncemented isoelastic monoblock acetabular components: lower wear rate with vitamin E blended highly cross-linked polyethylene compared to ultra-high molecular weight polyethylene. Acta Orthop 2020; 91(3): 254–9.
- Yamamoto K, Tateiwa T, Takahashi Y. vitamin E-stabilized highly crosslinked polyethylenes: the role and effectiveness in total hip arthroplasty. J Orthop Sci 2017; 22(3): 384–90.
- Young A M, Sychterz C J, Hopper R H, Engh C A. Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty. J Bone Joint Surg Am 2002; 84(1): 58–63.
Acta Orthopaedica
Volume 91, 2020 - Issue 6
Open access
2,008
Views
15
CrossRef citations to date
0
Altmetric
Research Article
A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients
Julie R A Massiera Clinical Orthopedic Research Center – mN, Zeist;b Department of Orthopedic Surgery, Diakonessenhuis, Utrecht, the Netherlands
, Joost H J Van Erpa Clinical Orthopedic Research Center – mN, Zeist;b Department of Orthopedic Surgery, Diakonessenhuis, Utrecht, the NetherlandsCorrespondence[email protected]
, Thom E Snijdersa Clinical Orthopedic Research Center – mN, Zeist
& Arthur DE Gasta Clinical Orthopedic Research Center – mN, Zeist;b Department of Orthopedic Surgery, Diakonessenhuis, Utrecht, the Netherlands
Pages 705-710
|
Published online: 24 Aug 2020
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.