4,095
Views
2
CrossRef citations to date
0
Altmetric
Research Article

The STRYDE limb lengthening nail is susceptible to mechanically assisted crevice corrosion: an analysis of 23 retrieved implants

, , , , , , , , & show all

  • Agarwal A, Kelkar A, Agarwal A G, Jayaswal D, Jayaswal A, Shendge V. Device-related complications associated with MAGEC rod usage for distraction-based correction of scoliosis. Spine Surg Relat Res 2020; 4(2): 148–51.
  • Akbarnia B A, Mundis G M. Magnetically controlled growing rods in early onset scoliosis. Orthopade 2019; 48(6): 477–85.
  • Alrabai H M, Gesheff M G, Conway J D. Use of internal lengthening nails in post-traumatic sequelae. Int Orthop 2017; 41(9): 1915–23.
  • ASTM F2229-21, Standard Specification for Wrought, Nitrogen Strengthened 23Manganese-21Chromium-1Molybdenum Low-Nickel Stainless Steel Alloy Bar and Wire for Surgical Implants (UNS S29108). West Conshohocken, PA: ASTM International; 2021.
  • Baba H, Katada Y. Effect of nitrogen on crevice corrosion in austenitic stainless steel. Corros Sci 2006; 48(9): 2510–24.
  • Calder P R, McKay J E, Timms A J, Roskrow T, Fugazzotto S, Edel P, Goodier W D. Femoral lengthening using the Precice intramedullary limb-lengthening system: outcome comparison following antegrade and retrograde nails. Bone Joint J 2019; 101-B(9): 1168–76.
  • Eltayeby H H, Alrabai H M, Jauregui J J, Shabtai L Y, Herzenberg J E. Post-retrieval functionality testing of PRECICE lengthening nails: the “sleeper” nail concept. J Clin Orthop Trauma 2021; 14: 151–5.
  • Frost M, Rahbek O, Traerup J, Ceccotti A A, Kold S. Systematic review of complications with externally controlled motorized intramedullary bone lengthening nails (FITBONE and PRECICE) in 983 segments. Acta Orthop 2021; 91(1): 120–7.
  • Hammouda A I, Szymczuk V L, Gesheff M G, Mohamed N S, Conway J D, Standard S C, McClure P K, Herzenberg J E. Acute deformity correction and lengthening using the PRECICE magnetic intramedullary lengthening nail. J Limb Lengthen Reconstr 2020; 6: 20–7.
  • Horn J, Hvid I, Huhnstock S, Breen A B, Steen H. Limb lengthening and deformity correction with externally controlled motorized intramedullary nails: evaluation of 50 consecutive lengthenings. Acta Orthop 2019; 90(1): 81–7.
  • Iliadis A D, Wright J, Stoddart M T, Goodier W D, Calder P. Early results from a single centre’s experience with the STRYDE nail. Bone Joint J. 2021a. In press (personal communication)
  • Iliadis A D, Palloni V, Wright J, Goodier D, Calder P. Pediatric lower limb lengthening using the PRECICE nail: our experience with 50 cases. J Pediatr Orthop 2021b; 41(1): e44-9.
  • Johnson M A, Karkenny A J, Arkader A, Davidson R S. Dissociation of a femoral intramedullary magnetic lengthening nail during routine hardware removal. JBJS Case Connect 2021; 11(1): 1–5.
  • Joyce T J, Smith S L, Kandemir G, Rushton P R P, Fender D, Bowey A J, Gibson M J. The NuVasive MAGEC rod urgent field safety notice concerning locking pin fracture: how does data from an independent explant center compare? Spine 2020; 45(13): 872–6.
  • Kamachi Mudali U, Shankar P, Ningshen S, Dayal R K, Khatak H S, Raj B. On the pitting corrosion resistance of nitrogen alloyed cold worked austenitic stainless steels. Corros Sci 2002; 44(10): 2183–98.
  • Lee D H, Kim S, Lee J W, Park H, Kim T Y, Kim H W. A comparison of the device-related complications of intramedullary lengthening nails using a new classification system. Biomed Res Int 2017; 2017: 8032510.
  • Lim Y S, Kim J S, Ahn S J, Kwon H S, Katada Y. The influences of microstructure and nitrogen alloying on pitting corrosion of type 316L and 20 wt.% Mn-substituted type 316L stainless steels. Corros Sci 2001; 43(1): 53–68.
  • Morrison S G, Georgiadis A G, Huser A J, Dahl M T. Complications of limb lengthening with motorized intramedullary nails. J Am Acad Orthop Surg 2020; 28(18): e803-9.
  • Nasto L A, Coppa V, Riganti S, Ruzzini L, Manfrini M, Campanacci L, Palmacci O, Boero S. Clinical results and complication rates of lower limb lengthening in paediatric patients using the PRECICE 2 intramedullary magnetic nail: a multicentre study. J Pediatr Orthop B 2020; 29(6): 611–17.
  • Panagiotopoulou V C, Davda K, Hothi H S, Henckel J, Cerquiglini A, Goodier W D, Skinner J, Hart A, Calder P R. A retrieval analysis of the Precice intramedullary limb lengthening system. Bone Joint Res 2018; 7(7): 476–84.
  • Robbins C, Paley D. Stryde Weight-bearing Internal Lengthening Nail. Tech Orthop 2020; 35(3): 201–8.
  • Rölfing J D, Kold S, Nygaard T, Mikuzis M, Brix M, Faergemann C, Gottliebsen M, Davidsen M, Petruskevicius J, Olesen U K. Pain, osteolysis, and periosteal reaction are associated with the STRYDE limb lengthening nail: a nationwide cross-sectional study. Acta Orthop 2021a; epub ahead of print. doi.org/https://doi.org/10.1080/17453674.2021.1903278
  • Rölfing J D, Bünger M, Petruskevicius J, Abood A. Removal of broken Stryde limb lengthening nails. Orthop Traumatol Surg Res 2021b; in press. https://doi.org/10.1016/j.otsr.2021.102958
  • Rushton P R P, Smith S L, Kandemir G, Forbes L, Fender D, Bowey A J, Gibson M J, Joyce T J. Spinal lengthening with magnetically controlled growing rods. Spine 2020; 45(3): 170–6.
  • Rushton P R P, Smith S L, Fender D, Bowey A J, Gibson M J, Joyce T J. Metallosis is commonly associated with magnetically controlled growing rods: results from an independent multicentre explant database. Eur Spine J 2021; epub ahead of print. doi.org/https://doi.org/10.1007/s00586-021-06750-2
  • Skov S T, Bünger C, Rölfing J D, Hansen E S, Høy K, Valencius K, Hemig P, Li H. High global satisfaction in magnetically controlled elongations in 29 early-onset scoliosis patients versus primary spinal fusion in 20 adolescent idiopathic scoliosis patients. Open J Orthop Rheumatol 2019; 4(1): 005–9.
  • Skov S T, Bünger C, Li H, Vigh-Larsen M, Rölfing J D. Lengthening of magnetically controlled growing rods caused minimal pain in 25 children: pain assessment with FPS-R, NRS, and r-FLACC. Spine Deform 2020a; 8(4): 763–70.
  • Skov S T, Li H, Hansen E S, Høy K, Helmig P, Rölfing J D, Bünger C. New growth rod concept provides three dimensional correction, spinal growth, and preserved pulmonary function in early-onset scoliosis. Int Orthop 2020b; 44(9): 1773–83.
  • Tang N, Zhao H, Shen J-X, Zhang J-G, Li S-G. Magnetically controlled growing rod for early-onset scoliosis: systematic review and meta-analysis. World Neurosurg 2019; 125: e593-601.
  • Toor I-H, Park K J, Kwon H. Manganese effects on repassivation kinetics and SCC susceptibility of high Mn-N austenitic stainless steel alloys. J Electrochem Soc 2007; 154(9): C494.
  • Tsirikos A I, Roberts S B. Magnetic controlled growth rods in the treatment of scoliosis: safety, efficacy and patient selection. Med Devices Evid Res 2020; 13: 75–85.
  • Vogt B, Rödl R, Gosheger G, Schulze M, Hasselmann J, Fuest C, Toporowski G, Laufer A, Frommer A. Focal osteolysis and corrosion at the junction of Precice Stryde intramedullary lengthening device: preliminary clinical, radiographic and metallurgic analysis of 57 lengthened segments. Bone Joint Res 2021 (under review/personal communication).
  • Wang Q, Zhang B, Ren Y, Yang K. Eliminating detrimental effect of cold working on pitting corrosion resistance in high nitrogen austenitic stainless steels. Corros Sci 2017; 123: 351–5.
  • Wei J Z, Hothi H S, Morganti H, Bergiers S, Dal Gal E, Likcani D, Henckel J, Hart A J. Mechanical wear analysis helps understand a mechanism of failure in retrieved magnetically controlled growing rods: a retrieval study. BMC Musculoskelet Disord 2020; 21(1): 519.