Advances in the tools and techniques of vitreoretinal surgery

, , , & ORCID Icon
Pages 331-345 | Received 28 Mar 2020, Accepted 11 Aug 2020, Published online: 21 Sep 2020

References

  • Machemer R. Vitrectomy, A pars plana approach. Trans Am Acad Ophthaimol. 1971;75:813–820.
  • Recchia FM, Scott IU, Brown GC, et al. Small-gauge pars plana vitrectomy: a report by the American Academy of Ophthalmology. Ophthalmology. 2010 Sep;117(9):1851–1857.
  • KASNER D. Vitrectomy : a new approach to management of vitreous. HGL Ophthalmol. 1969;11:304.
  • O’Malley C, Heintz RM. Vitrectomy with an alternative instrument system. Ann Ophthalmol. 1975.
  • Littmann H. [A new surgical microscope]. Klin Monbl Augenheilkd Augenarztl Fortbild. 1954;124(4):473–476.
  • Barraquer JI. The history of the microscope in ocular surgery. J Microsurg. 1980 Feb;1(4):288–299.
  • Eckardt C, Paulo EB. Heads-up surgery for vitreoretinal procedures: an Experimental and Clinical Study. Retina. 2016 Jan;36(1):137–147.
  • Kumar A, Hasan N, Kakkar P, et al. Comparison of clinical outcomes between “heads-up” 3D viewing system and conventional microscope in macular hole surgeries: A pilot study. Indian J Ophthalmol. 2018 Dec;66(12):1816–1819.
  • Machemer R, Parel J-M, Buettner H. A New Concept for Vitreous Surgery: 1. Instrumentation. Am J Ophthalmol. 1972 Jan 1;73(1):1–7.
  • Inoue M. Wide-Angle Viewing System. Microin Vitrect Sur. 2014;54:87–91.
  • Gulkas S, Cekic O Intraoperative Optical Coherence Tomography. Novel Diagnostic Methods in Ophthalmology [Internet]. 2019 Jul 16 cited 2020 Mar 26; Available from: https://www.intechopen.com/books/novel-diagnostic-methods-in-ophthalmology/intraoperative-optical-coherence-tomography
  • Ehlers JP, Tao YK, Farsiu S, et al. Integration of a Spectral Domain Optical Coherence Tomography System into a Surgical Microscope for Intraoperative Imaging. Invest Ophthalmol Vis Sci. 2011 May 1;52(6):3153–3159.
  • Ehlers JP, Tao YK, Farsiu S, et al. Visualization of Real-Time Intraoperative Maneuvers with a Microscope-Mounted Spectral Domain Optical Coherence Tomography System. Retina. 2013 Jan;33(1):232–236.
  • OSA | microscope-integrated intraoperative OCT with electrically tunable focus and heads-up display for imaging of ophthalmic surgical maneuvers [Internet]. cited 2020 Mar 26. Available from: https://www.osapublishing.org/boe/abstract.cfm?uri=boe-5-6-1877
  • Viehland C, Keller B, Carrasco-Zevallos OM, et al. Enhanced volumetric visualization for real time 4D intraoperative ophthalmic swept-source OCT. Biomed Opt Express BOE. 2016 May 1;7(5):1815–1829.
  • Ehlers JP, Khan M, Petkovsek D, et al. Outcomes of Intraoperative OCT–Assisted Epiretinal Membrane Surgery from the PIONEER Study. Ophthalmol Retina. 2018 Apr 1;2(4):263–267.
  • Bruyère E, Philippakis E, Dupas B, et al. Benefit of intraoperative optical coherence tomography for vitreomacular surgery in highly myopic eyes. Retina. 2018 Oct;38(10):2035–2044.
  • Agarwal A, Gupta V. Intraoperative optical coherence tomography and proportional reflux hydrodissection-guided pars plana vitrectomy for complex severe proliferative diabetic retinopathy. Indian J Ophthalmol. 2020;68(1):177–181.
  • Endoscopic vitrectomy : current Opinion in Ophthalmology [Internet]. cited 2020 Mar 26. Available from: https://journals.lww.com/co-ophthalmology/Abstract/2014/05000/Endoscopic_vitrectomy.9.aspx
  • Mura M, de Smet MD. Endoscopic Retinal Detachment Repair in Patients With Media Opacities. Invest Ophthalmol Vis Sci. 2007 May 10;48(13):5763.
  • Endoscopic Vitrectomy for Severe Posttraumatic Endophthamitis with Visualization Constraints [Internet]. cited 2020 Mar 26. Available from: https://www.healio.com/ophthalmology/journals/osli/2011-11-42-6/%7B380c3500-d09c-4fc8-84a5-fadb85d48bf0%7D/endoscopic-vitrectomy-for-severe-posttraumatic-endophthamitis-with-visualization-constraints
  • Retinal Physician - Ultra-High-Speed Vitrectomy Cutters: what’s the Limit? [Internet]. Retinal Physician. cited 2020 Mar 26. Available from: https://www.retinalphysician.com/issues/2018/october-2018/ultra-high-speed-vitrectomy-cutters-what-8217;s
  • Zehetner C, Moelgg M, Bechrakis E, et al. IN VITRO FLOW ANALYSIS OF NOVEL DOUBLE-CUTTING, OPEN-PORT, ULTRAHIGH-SPEED VITRECTOMY SYSTEMS. RETINA. 2018 Dec;38(12):2309–2316.
  • Stanga PE, Pastor-Idoate S, Zambrano I, et al. Performance analysis of a new hypersonic vitrector system. PLoS One. [ [Internet]. 2017 Jun 6 cited 2020 Mar 26;12(6). Available from]. [];(). : https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5460816/
  • Peyman GA. Improved vitrectomy illumination system. Am J Ophthalmol. 1976 Jan;81(1):99–100.
  • Illumination and Phototoxicity Issues in Vitreoretinal Surge … : RETINA [Internet]. cited 2020 Mar 26. Available from: https://journals.lww.com/retinajournal/Citation/2008/01000/Illumination_and_Phototoxicity_Issues_in.1.aspx
  • Chow DR. The Evolution of Endoillumination. Microin Vitrect Sur. 2014;54:77–86.
  • Koch FH, Pawlowski D, Spitznas M. A multiport illumination system for panoramic bi-manual vitreous surgery. Graefes Arch Clin Exp Ophthalmol. 1991;229(5):425–429.
  • Eckardt C. Twin lights: a new chandelier illumination for bimanual surgery. Retina. 2003 Dec;23(6):893–894.
  • Seider MI, Nomides REK, Hahn P, et al. Scleral Buckling with Chandelier Illumination. J Ophthalmic Vis Res. 2016;11(3):304–309.
  • Fujii GY, de Juan E, Humayun MS, et al. A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch and Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article. Ophthalmology. 2002 Oct 1;109(10):1807–1812.
  • TRANSCONJUNCTIVAL SUTURELESS 23-GAUGE VITRECTOMY : RETINA [Internet]. cited 2020 Mar 26. Available from: https://journals.lww.com/retinajournal/Citation/2005/02000/TRANSCONJUNCTIVAL_SUTURELESS_23_GAUGE_VITRECTOMY.15.aspx
  • Osawa S, Oshima Y. 27-Gauge Vitrectomy. Microin Vitrect Sur. 2014;54:54–62.
  • Mitsui K, Kogo J, Takeda H, et al. Comparative study of 27-gauge vs 25-gauge vitrectomy for epiretinal membrane. Eye (Lond). 2016 Apr;30(4):538–544.
  • Rizzo S, Barca F, Caporossi T, et al. Twenty-seven-gauge vitrectomy for various vitreoretinal diseases. Retina (Philadelphia, Pa). 2015 Jun;35(6):1273–1278.
  • Chan CK, Lin SG, Nuthi ASD, et al. Pneumatic Retinopexy for the Repair of Retinal Detachments: A Comprehensive Review (1986–2007). Surv Ophthalmol. 2008 Sep 1;53(5):443–478.
  • Anterior segment complications related to vitreous substitutes. - Abstract - Europe PMC [Internet]. cited 2020 Mar 26. Available from: https://europepmc.org/article/med/15533750
  • The Use of Liquid Silicone in Retinal Detachment Surgery | JAMA Ophthalmology | JAMA Network [Internet]. cited 2020 Mar 26. Available from: https://jamanetwork.com/journals/jamaophthalmology/article-abstract/627022
  • Chemical and physical aspects of clinically applied silicones. - Abstract - Europe PMC [Internet]. cited 2020 Mar 26. Available from: https://europepmc.org/article/med/3653471
  • Chang S. Low Viscosity Liquid Fluorochemicals in Vitreous Surgery. Am J Ophthalmol. 1987 Jan 1; 103(1):38–43.
  • Mikhail MA, Mangioris G, Best RM, et al. Management of giant retinal tears with vitrectomy and perfluorocarbon liquid postoperatively as a short-term tamponade. Eye. 2017 Sep;31(9):1290–1295.
  • Pubmeddev, al RR et. Intraoperative Macula Protection by Perfluorocarbon Liquid for the Metallic Intraocular Foreign Body Removal during 23-Gauge Vitrectomy. - PubMed - NCBI [Internet]. cited 2020 Mar 27. Available from: https://www.ncbi.nlm.nih.gov/pubmed/28553550
  • Rejdak R, Choragiewicz T, Moneta-Wielgos J, et al. Intraoperative Macula Protection by Perfluorocarbon Liquid for the Metallic Intraocular Foreign Body Removal during 23-Gauge Vitrectomy. J Ophthalmol. 2017;2017:6232151.
  • Watanabe A, Gekka T, Tsuneoka H. Treatment of a dislocated lens by transcorneal vitrectomy and bimanual phacoemulsification. Clin Ophthalmol. 2014;8:1539–1542.
  • Vuković D, Petrović S, Paović P. Secondary surgical management of suprachoroidal hemorrhage during pars plana vitrectomy. Vojnosanit Pregl. 2015 Mar;72(3):287–290.
  • Experimental short-term tolerance to perfluorodecalin in the rabbit eye: a histopathological study. Curr Eye Res. [Internet]. 1998 Aug [cited 2020 Mar 26;17(8):828–835. Available from: https://www.tandfonline.com/doi/abs/10.1080/02713689808951265
  • Heavy tamponade 1: a review of indications, use, and complications | eye [Internet]. cited 2020 Mar 26. Available from: https://www.nature.com/articles/eye200861
  • Sandner D, Engelmann K. First experiences with high-density silicone oil (Densiron) as an intraocular tamponade in complex retinal detachment. Graefe’s Arch Clin Exp Ophthalmo. 2006 May 1;244(5):609–619.
  • Rodrigues EB, Meyer CH, Farah ME, et al. Intravitreal staining of the internal limiting membrane using indocyanine green in the treatment of macular holes. Ophthalmologica. 2005 Oct;219(5):251–262.
  • Feron EJ, Veckeneer M, Parys-Van Ginderdeuren R, et al. Trypan blue staining of epiretinal membranes in proliferative vitreoretinopathy. Arch Ophthalmol. 2002 Feb;120(2):141–144.
  • Kumar A, Gogia V, Shah VM, et al. Comparative evaluation of anatomical and functional outcomes using brilliant blue G versus triamcinolone assisted ILM peeling in macular hole surgery in Indian population. Graefes Arch Clin Exp Ophthalmol. 2011 Jul;249(7):987–995.
  • Shroff D, Agarwal A, Saha I, et al. Retinal pigment epithelial irregularity and atrophy after internal membrane peeling: a report of two cases. Retin Cases Brief Rep. 2020 Jan 22. DOI:10.1097/ICB.0000000000000972. Online ahead of print.
  • Bressler NM, Bressler SB, Childs AL, et al. Surgery for hemorrhagic choroidal neovascular lesions of age-related macular degeneration: ophthalmic findings: SST report no. 13. Ophthalmology. 2004 Nov;111(11):1993–2006.
  • Subretinal Pneumatic Displacement of Subretinal Hemorrhage | surgery | JAMA Ophthalmology | JAMA Network [Internet]. cited 2020 Mar 26. Available from: https://jamanetwork.com/journals/jamaophthalmology/fullarticle/1789795
  • Martel JN, Mahmoud TH. Subretinal Pneumatic Displacement of Subretinal Hemorrhage. JAMA Ophthalmol. 2013 Dec 1;131(12):1632–1635.
  • Johnston RL, Tufail A, Lightman S, et al. Retinal and choroidal biopsies are helpful in unclear uveitis of suspected infectious or malignant origin. Ophthalmology. 2004 Mar;111(3):522–528.
  • Nussenblatt RB, Davis JL, Palestine AG. Chorioretinal biopsy for diagnostic purposes in cases of intraocular inflammatory disease. Dev Ophthalmol. 1992;23:133–138.
  • Ahuja AK, Behrend MR. The ArgusTM II retinal prosthesis: factors affecting patient selection for implantation. Prog Retin Eye Res. 2013 Sep;36:1–23.
  • Humayun MS, Dorn JD, da Cruz L, et al. Interim results from the international trial of Second Sight’s visual prosthesis. Ophthalmology. 2012 Apr;119(4):779–788.
  • Ip MS, Baker BJ, Duker JS, et al. Anatomical outcomes of surgery for idiopathic macular hole as determined by optical coherence tomography. Arch Ophthalmol. 2002 Jan;120(1):29–35.
  • Michalewska Z, Michalewski J, Adelman RA, et al. Inverted internal limiting membrane flap technique for large macular holes. Ophthalmology. 2010 Oct;117(10):2018–2025.
  • Lai -C-C, Hwang Y-S, Liu L, et al. Blood-assisted internal limiting membrane peeling for macular hole repair. Ophthalmology. 2009 Aug;116(8):1525–1530.
  • Wong R, Howard C, Orobona GD. RETINA EXPANSION TECHNIQUE FOR MACULAR HOLE APPOSITION REPORT 2: efficacy, Closure Rate, and Risks of a Macular Detachment Technique to Close Large Full-Thickness Macular Holes. Retina (Philadelphia, Pa). 2018 Apr;38(4):660–663.
  • Tanaka S, Inoue M, Inoue T, et al. Autologous retinal transplantation as a primary treatment for large chronic macular holes. Retina. 2019 Nov 28. DOI:10.1097/IAE.0000000000002693. Online ahead of print.
  • Azuara-Blanco A, Pillai CT, Dua HS. Amniotic membrane transplantation for ocular surface reconstruction. Br J Ophthalmol. 1999 Apr;83(4):399–402.
  • Rizzo S, Caporossi T, Tartaro R, et al. A Human Amniotic Membrane Plug to Promote Retinal Breaks Repair and Recurrent Macular Hole Closure. Retina (Philadelphia, Pa). 2019 Oct;39(Suppl 1):S95–103.
  • Capeáns C, Piñeiro A, Pardo M, et al. Amniotic membrane as support for human retinal pigment epithelium (RPE) cell growth. Acta Ophthalmol Scand. 2003 Jun;81(3):271–277.
  • Ohno-Matsui K, Ichinose S, Nakahama K, et al. The effects of amniotic membrane on retinal pigment epithelial cell differentiation. Mol Vis. 2005 Jan;6(11):1–10.
  • Banaee T, Hosseini SM, Eslampoor A, et al. 360 degrees retinectomy in complex retinal detachment. Retina (Philadelphia, Pa). 2009 Jun;29(6):811–818.
  • Tseng JJ, Barile GR, Schiff WM, et al. Influence of relaxing retinotomy on surgical outcomes in proliferative vitreoretinopathy. Am J Ophthalmol. 2005 Oct;140(4):628–636.
  • He X, Gehlbach P, Handa J, et al. Toward robotically assisted membrane peeling with 3-DOF distal force sensing in retinal microsurgery. Conf Proc IEEE Eng Med Biol Soc. 2014;2014:6859–6863.
  • Gonenc B, Gehlbach P, Taylor RH, et al. Effects of Micro-Vibratory Modulation during Robot-Assisted Membrane Peeling. Rep U S. 2015 Oct;2015:3811–3816.
  • Gonenc B, Handa J, Gehlbach P, et al. Study for Robot Assisted Vitreoretinal Surgery: micron vs. the Steady-Hand Robot. IEEE Int Conf Robot Autom. 2013;4832–4837.
  • Gonenc B, Tran N, Gehlbach P, et al. Robot-assisted retinal vein cannulation with force-based puncture detection: micron vs. the steady-hand eye robot. Conf Proc IEEE Eng Med Biol Soc. 2016 Aug;2016:5107–5111.
  • Gonenc B, Chamani A, Handa J, et al. 3-DOF Force-Sensing Motorized Micro-Forceps for Robot-Assisted Vitreoretinal Surgery. IEEE Sens J. 2017 Jun 1;17(11):3526–3541.
  • Kuru I, Gonenc B, Balicki M, et al. Force sensing micro-forceps for robot assisted retinal surgery. Conf Proc IEEE Eng Med Biol Soc. 2012;2012:1401–1404.
  • Song C, Gehlbach PL, Kang JU. Swept source optical coherence tomography based smart handheld vitreoretinal microsurgical tool for tremor suppression. Conf Proc IEEE Eng Med Biol Soc. 2012;2012:1405–1408.
  • Lee JH, Tanaka E, Woo Y, et al. Advanced real-time multi-display educational system (ARMES): an innovative real-time audiovisual mentoring tool for complex robotic surgery. J Surg Oncol. 2017 Dec;116(7):894–897.
  • Russell S, Bennett J, Wellman JA, et al. Efficacy and safety of voretigene neparvovec (AAV2-hRPE65v2) in patients with RPE65-mediated inherited retinal dystrophy: a randomised, controlled, open-label, phase 3 trial. Lancet. 2017 Aug 26;390(10097):849–860.
  • Cai X, Conley SM, Naash MI. RPE65: role in the visual cycle, human retinal disease, and gene therapy. Ophthalmic Genet. 2009 Jun;30(2):57–62.
  • Cong L, Ran FA, Cox D, et al. Multiplex genome engineering using CRISPR/Cas systems. Science. 2013 Feb 15;339(6121):819–823.
  • ADVM-022 Intravitreal Gene Therapy for Wet AMD - Full Text View - ClinicalTrials.gov [Internet]. cited 2020 May 3. Available from: https://clinicaltrials.gov/ct2/show/NCT03748784
  • Agranat JS, Miller JB, Douglas VP, et al. The Scope Of Three-Dimensional Digital Visualization Systems In Vitreoretinal Surgery. Clin Ophthalmol. 2019;13:2093.
  • Mura M, Barca F. 25-Gauge vitrectomy. Dev Ophthalmol. 2014;54:45–53.
  • Naruse S, Shimada H, Mori R. 27-gauge and 25-gauge vitrectomy day surgery for idiopathic epiretinal membrane. BMC Ophthalmol. 2017 Oct 10;17(1):188.
  • Someya H, Takayama K, Takeuchi M, et al. Outcomes of 25-Gauge Vitrectomy for Tractional and Nontractional Diabetic Macular Edema with Proliferative Diabetic Retinopathy. J Ophthalmol. 2019;2019:5304524.
  • Fujiwara N, Tomita G, Yagi F. Incidence and Risk Factors of Iatrogenic Retinal Breaks: 20-Gauge versus 25-Gauge Vitrectomy for Idiopathic Macular Hole Repair. J Ophthalmol. 2020;2020:5085180.
  • Govetto A, Virgili G, Menchini F, et al. A systematic review of endophthalmitis after microincisional versus 20-gauge vitrectomy. Ophthalmology. 2013 Nov;120(11):2286–2291.
  • Chen G, Tzekov R, Li W, et al. INCIDENCE OF ENDOPHTHALMITIS AFTER VITRECTOMY: A Systematic Review and Meta-analysis. Retina (Philadelphia, Pa). 2019 May;39(5):844–852.
  • Garweg JG, Ouassi D, Pfister IB. Hybrid 23/27 Gauge Vitrectomy - Combining the Charm of 27G with the Efficacy of 23G. Clin Ophthalmol. 2020;14:299–305.
  • Shinkai Y, Oshima Y, Yoneda K, et al. Multicenter survey of sutureless 27-gauge vitrectomy for primary rhegmatogenous retinal detachment: a consecutive series of 410 cases. Graefes Arch Clin Exp Ophthalmol. 2019 Dec;257(12):2591–2600.
  • Katoch D, Bansal R, Nijhawan R, et al. Primary intraocular central nervous system lymphoma masquerading as diffuse retinal vasculitis. BMJ Case Rep. 2013 Apr;30:2013.
  • Gujral GS, Agarwal M, Mayor R, et al. Clinical profile and management outcomes of traumatic submacular hemorrhage. J Curr Ophthalmol. 2019 Dec;31(4):411–415.
  • Wilkins CS, Mehta N, Wu CY, et al. Outcomes of pars plana vitrectomy with subretinal tissue plasminogen activator injection and pneumatic displacement of fovea-involving submacular haemorrhage. BMJ Open Ophthalmol. 2020;5(1):e000394.
  • Yiu G, Chung SH, Mollhoff IN, et al. Suprachoroidal and subretinal injections of AAV using transscleral microneedles for retinal gene delivery in nonhuman primates. Mol Ther Methods Clin Dev. 2020 Mar;13(16):179–191.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.