535
Views
3
CrossRef citations to date
0
Altmetric
ARTICLE

Monte Carlo Simulation Using Japanese Voxel Phantoms to Analyze the Contribution ofParticle Types and Their Energy Distributions to Organ Doses upon External Neutron Exposure

, , &
Pages 62-69 | Received 26 Mar 2009, Accepted 15 Sep 2009, Published online: 05 Jan 2012

References

  • ICRP/ICRU . 1963 . Health Physics , 9 ( 4 ) : 357 – 384 . “Report of the RBE committee to the international commissions on radiological protection and on radiological units and measurements,”
  • Satoh , D. , Takahashi , F. , Endo , A. , Ohmachi , Y. and Miyahara , N. 2008 . “Calculation of dose contributions of electron and charged heavy particles inside phantoms irradiated by monoenergetic neutron” . J. Radiat. Res. , 49 : 503 – 508 .
  • Zaidi , H. and Xu , X. G. 2007 . “Computational anthropomorphic models of the human anatomy: The path to realistic Monte Carlo modeling in radiological sciences” . Annu. Rev. Biomed. Eng. , 9 : 471 – 500 .
  • Sato , K. , Noguchi , H. , Emoto , Y. , Koga , S. and Saito , K. 2007 . “Japanese adult male voxel phantom constructed on the basis of CT images” . Radiat. Prot. Dosim. , 123 : 337 – 344 .
  • Sato , K. and Endo , A. 2008 . “Analysis of effects of posture on organ doses by internal photon emitters using voxel phantoms” . Phys. Med. Biol. , 53 : 4555 – 4572 .
  • Sato , K. , Endo , A. and Saito , K. 2008 . Dose Conversion Coefficients Calculated Using a Series of Adult Japanese Voxel Phantoms against External Photon Exposure , JAEA-Data/Code 2008–016 Japan Atomic Energy Agency (JAEA) .
  • Nelson , W. R. , Hirayama , H. and Rogers , D. W. O. 1985 . The EGS4 Code System , SLAC-R-265, Stanford Linear Accelerator Center (SLAC) Stanford University .
  • Iwase , H. , Niita , K. and Nakamura , T. 2002 . “Development of generalpurpose particle and heavy ion transport Monte Carlo code” . J. Nucl. Sci. Technol. , 39 : 1142 – 1151 .
  • Sato , T. , Sihver , L. , Iwase , H. , Nakashima , H. and Niita , K. 2005 . “Simulations of an accelerator-based shielding experiment using the particle and heavy-ion transport code system PHITS” . Advances in Space Research , 35 : 208 – 213 .
  • Sato , T. , Niita , K. Iwase , H. 2006 . “Applicability of particle and heavy ion transport code PHITS to the shielding design of spacecrafts” . Radiat. Meas. , 41 : 1142 – 1146 .
  • ICRP . 1996 . Ann. ICRP , 26 ( 3–4 ) Conversion Coefficients for Use in Radiological Protection against External Radiation, Publication 74, International Commission on Radiological Protection (ICRP)
  • Zhang , G. , Liu , Q. and Luo , Q. 2007 . “Monte Carlo simulations for external neutron dosimetry based on the visible Chinese human phantom” . Phys. Med. Biol. , 52 : 7367 – 7383 .
  • Zhang , G. , Luo , Q. , Zeng , S. and Liu , Q. 2008 . “The development and application of the visible Chinese human model for Monte Carlo dose calculations” . Health Phys. , 94 : 118 – 125 .
  • Pelowitz , D. B. 2005 . MCNPX User's Manual Version 2.5.0 , LACP-05–0369 Los Alamos National Laboratory (LANL) .
  • ICRP . 2002 . Ann. ICRP , 32 ( 3–4 ) Basic Anatomical and Physiological Data for Use in Radiological Protection: Reference Values, Publication 89, International Commission on Radiological Protection (ICRP)
  • Schlattl , H. , Zankl , M. and Petoussi-Henss , N. 2007 . “Organ dose conversion coefficients for voxel models of the reference male and female from idealized photon exposures” . Phys. Med. Biol. , 52 : 2123 – 2145 .
  • Briesmeister , J. B. 2000 . MCNP—A General Monte Carlo N-Particle Transport Code, Version 4C LA-13709-M, Los Alamos National Laboratory (LANL)
  • Prael , R. E. and Lichtenstein , H. 1989 . User guide to LCS: The LAHET code system , LA-UR-89–3014 Los Alamos National Laboratory (LANL) .
  • Emmett , M. B. 1975 . The MORSE Monte Carlo Radiation Transport System , ORNL-4972 Oak Ridge National Laboratory (ORNL) .
  • Lichtenstein , H. , Cohen , M. O. , Steinber , H. A. , Trubetzkoy , E. S. and Beer , M. 1979 . The SAM-CE Monte Carlo System for Radiation Transport and Criticality Calculations in Complex Configurations , Revision 7.0 Computer Code Manual of the Electric Power Research Institutes (MAGI) EPRI-CCM-8 Mathematical Application Group Inc. .
  • Nara , Y. , Otuka , N. , Ohnishi , A. , Niita , K. and Chiba , S. 1999 . “Relativistic nuclear collisions at 10A GeV energies from p+Be to Au+Au with the hadronic cascade model” . Phys. Rev. C , 61 : 024901 – 19 .
  • Niita , K. , Chiba , S. Maruyama , T. 1995 . “Analysis of the (N, xN′) reactions by quantum molecular dynamics plus statistical decay model” . Phys. Rev. C , 52 : 2620 – 2635 .
  • Furihata , S. 2000 . “Statistical analysis of light fragment production from medium energy proton-induced reactions” . Nucl. Instrum. Methods B , 171 : 251 – 258 .
  • Chadwick , M. B. , Oblozinsky , P. Herman , M. 2006 . “ENDF/B-VII.0: Next generation evaluated nuclear-data library for nuclear science and technology” . Nucl. Data Sheets , 107 : 2931 – 3060 .
  • ICRU . 2000 . Nuclear Data for Neutron and Proton Radiotherapy and for Radiation Protection , Report 63 International Commission on Radiation Units and Measurements(ICRU) .
  • Niita , K. , Iwamoto , Y. Sato , T. 2008 . “A new treatment of radiation behavior beyond one-body observables” . In Int. Conf. Nuclear Data for Science and Technology (ND 2007) Nice , , France Apr. 22–27, 2007, DOI: 10.1051/ndata:07398
  • Sato , T. , Endo , A. , Zankl , M. , Petoussi-Henss , N. and Niita , K. 2009 . “Fluence-to-dose conversion coefficients for neutrons and protons calculated using the PHITS code and ICRP/ICRU adult reference computational phantoms” . Phys. Med. Biol. , 54 : 1997 – 2014 .
  • Snyder , W. S. , Ford , M. R. and Warner , G. G. 1978 . “Estimates of specific absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom” . In MIRD Pamphlet No. 5 revised Society of Nuclear Medicine, New York
  • Zhang , G. , Liu , Q. , Zeng , S. and Luo , Q. 2008 . “Organ dose calculations by Monte Carlo modeling of the updated VCH adult male phantom against idealized external proton exposure” . Phys. Med. Biol. , 53 : 3697 – 3722 .
  • Dietze , G. and Siebert , B. R. L. 1994 . “Photon and neutron dose contributions and mean quality factors in phantoms of different size irradiated by monoenergetic neutrons” . Radiat. Res. , 140 : 130 – 133 .
  • NCRP . 2005 . Extrapolation of Radiation-induced Cancer Risks from Nonhuman Experimental Systems to Humans , NCRP Rep. 150 National Council on Radiation Protection and Measurement (NCRP) .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.