Estimating ASHRAE Guideline 36 energy savings for multi-zone variable air volume systems using Spawn of EnergyPlus

ORCID Icon, ORCID Icon, ORCID Icon, , ORCID Icon &
Pages 215-236 | Received 14 Jun 2021, Accepted 16 Dec 2021, Published online: 28 Jan 2022

References

  • Abdel Haleem, S. M., G. S. Pavlak, and W. P. Bahnfleth. 2020. “Performance of Advanced Control Sequences in Handling Uncertainty in Energy Use and Indoor Environmental Quality Using Uncertainty and Sensitivity Analysis for Control Components.” Energy and Buildings 225: 110308.
  • American Society of Heating, Refrigeration and Air conditioning Engineers. 2004. ASHRAE Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings. Atlanta, GA: ASHRAE.
  • American Society of Heating, Refrigeration and Air conditioning Engineers. 2005. Sequences of Operation for Common HVAC Systems. Atlanta, GA: ASHRAE.
  • American Society of Heating, Refrigeration and Air conditioning Engineers. 2018. ASHRAE Guideline 36-2018 High-Performance Sequences of Operation for HVAC Systems. Atlanta, GA: ASHRAE.
  • American Society of Heating, Refrigeration and Air conditioning Engineers. 2019. ASHRAE Standard 62.1-2019, Ventilation for Acceptable Indoor Air Quality. Atlanta, GA: ASHRAE.
  • Barwig, F. E., J. M. House, C. J. Klaassen, M. M. Ardehali, and T. F. Smith. 2002. “The National Building Controls Information Program.” In 2002 Summer Study on Energy Efficiency in Buildings, 3.1–3.14. Pacific Grove, CA: ACEEE.
  • Blum, D., and K. Zhang. 2021. “Guideline 36 Savings Calculator v0.1.” Computer software. USDOE. Accessed June 2, 2021. doi:https://doi.org/10.11578/dc.20210610.1.
  • Chen, Y., T. Hong, and X. Luo. 2018. “An Agent-Based Stochastic Occupancy Simulator.” Building Simulation 11: 37–49. doi:https://doi.org/10.1007/s12273-017-0379-7.
  • Chidiac, S. E., E. J. C. Catania, E. Morofsky, and S. Foo. 2011. “A Screening Methodology for Implementing Cost Effective Energy Retrofit Measures in Canadian Office Buildings.” Energy and Buildings 43 (2): 614–620.
  • Cho, Y.-H., and M. Liu. 2010. “Improving Energy Efficiency with the Various Control Sequences for a VAV System Through Continuous Commissioning©.” International Journal of Energy Research 34: 1291–1301.
  • Clarke, J. A. 2001. Energy Simulation in Building Design. 2nd ed. Oxford: Butterworth-Heinemann. OCLC: ocm46693334.
  • Crawley, D. B., L. K. Lawrie, F. C. Winkelmann, W. Buhl, Y. Huang, C. O. Pedersen, R. K. Strand, et al. 2001. “EnergyPlus: Creating a New-Generation Building Energy Simulation Program.” Energy and Buildings 33: 319–331.
  • De Boeck, L., S. Verbeke, A. Audenaert, and L. De Mesmaeker. 2015. “Improving the Energy Performance of Residential Buildings: A Literature Review.” Renewable and Sustainable Energy Reviews 52: 960–975.
  • Deru, M., K. Field, D. Studer, K. Benne, B. Griffith, P. Torcellini, B. Liu, et al. 2011. U.S. Department of Energy Commercial Reference Building Models of the National Building Stock. Technical Report NREL/TP-5500-46861. National Renewable Energy Laboratory.
  • Englander, S., and L. Norford. 1992a. “Saving Fan Energy in VAV Systems – Part 1: Analysis of a Variable Speed Drive Retrofit.” ASHRAE Transactions 98.
  • Englander, S., and L. Norford. 1992b. “Variable Speed Drives: Improving Energy Consumption Modeling and Savings Analysis Techniques.” In ACEEE Summer Study Proceedings.
  • Fernandez, N., S. Katipamula, W. Wang, Y. Huang, and G. Liu. 2015. “Energy Savings Modelling of Re-Tuning Energy Conservation Measures in Large Office Buildings.” Journal of Building Performance Simulation 8: 391–407.
  • Fernandez, N., Y. Xie, S. Katipamula, M. Zhao, W. Wang, and C. Corbin. 2017. Impacts of Commercial Building Controls on Energy Savings and Peak Load Reduction. Technical Report PNNL-25985. Pacific Northwest National Laboratory. https://buildingretuning.pnnl.gov/publications/PNNL-25985.pdf.
  • Ferretti, N. M., M. A. Galler, S. T. Bushby, and J. Sorra. 2019. Commissioning ASHRAE High-Performance Sequences of Operation for Multiple-Zone Variable Air Volume Air Handling Units. NIST Technical Note 2024, Technical Report. National Institute of Standards and Technology. https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2024.pdf.
  • Hong, T., M. A. Piette, Y. Chen, S. H. Lee, S. C. Taylor-Lange, R. Zhang, K. Sun, and P. Price. 2015. “Commercial Building Energy Saver: An Energy Retrofit Analysis Toolkit.” Applied Energy 159: 298–309.
  • Hydeman, M., S. Taylor, and B. Eubanks. 2015. “Control Sequences & Controller Programming.” ASHRAE Journal. http://www.taylor-engineering.com/wp-content/uploads/2020/04/ASHRAE_Journal_-_Control_Sequences_and_Controller_Programming.pdf.
  • Hydeman, M., S. Taylor, J. Stein, E. Kolderup, and T. Hong. 2003. Advanced Variable Air Volume System Design Guide. Technical Report P500-03-082-A-11. California Energy Commission. https://newbuildings.org/sites/default/files/A-11_LG_VAV_Guide_3.6.2.pdf.
  • Im, P., J. R. New, and Y. Bae. 2019. “Updated Openstudio Small and Medium Office Prototype Models.” In Proceedings of the 16th IBPSA Conference, 1311–1317. Rome, Italy, September 2–4.
  • Katipamula, S., and N. Fernandez. 2020. Improving Commercial Building Operations Through Building Re-tuning: Meta-Analysis (Updated 2020). Technical Report PNNL-SA-156277. Pacific Northwest National Laboratory. https://buildingretuning.pnnl.gov/documents/PNNL-SA-156277_Re-tuningMeta-Analysis_2020-09-05.pdf.
  • Kiriu, R., and J. Stein. 2021. “Medical Office Building Thrives with Advanced Control Sequences.” ASHRAE Journal. https://tayloreng.egnyte.com/dl/OfrtxonS4C/ASHRAE_Journal_-_Medical_Office_Building_Thrives_With_Advanced_Control_Sequences.pdf_.
  • Ma, Z., P. Cooper, D. Daly, and L. Ledo. 2012. “Existing Building Retrofits: Methodology and State-of-the-Art.” Energy and Buildings, Cool Roofs, Cool Pavements, Cool Cities, and Cool World 55: 889–902.
  • Mattsson, S. E., and H. Elmqvist. 1997. “Modelica – An International Effort to Design the Next Generation Modeling Language.” In 7th IFAC Symposium on Computer Aided Control Systems Design, 151–155. Gent, Belgium, April 28–30.
  • Modelica Association. 2017. “Modelica – A Unified Object-Oriented Language for Physical Systems Modeling, Language Specification.” Version 3.4. https://www.modelica.org/documents/ModelicaSpec34.pdf.
  • Paliaga, G., R. Singla, C. Snaith, S. Lipp, D. Mangalekar, H. Cheng, and M. Pritoni. 2020. “Re-Envisioning RCx: Achieving Max Potential HVAC Controls Retrofits Through Modernized BAS Hardware and Software.” In 2020 Summer Study on Energy Efficiency in Buildings. Pacific Grove, CA, August 17–21.
  • Pang, X., M. A. Piette, and N. Zhou. 2017. “Characterizing Variations in Variable Air Volume System Controls.” Energy and Buildings 135: 166–175.
  • Pritoni, M., A. Prakash, D. Blum, K. Zhang, R. Tang, J. Granderson, H. Cheng, and G. Paliaga. 2020. “Advanced Control Sequences and FDD Technology. Just Shiny Objects, Or Ready for Scale?” In 2020 Summer Study on Energy Efficiency in Buildings. Pacific Grove, CA, August 17–21.
  • Regnier, C., K. Sun, T. Hong, and M. A. Piette. 2018. “Quantifying the Benefits of a Building Retrofit Using An Integrated System Approach: A Case Study.” Energy and Buildings 159: 332–345.
  • Rosenberg, M., D. Jones, R. Hart, M. Cooper, and M. Hatten. 2017. Implementation of Energy Code Controls Requirements in New Commercial Buildings. Technical Report. Pacific Northwest National Laboratory.
  • Ruparathna, R., K. Hewage, and R. Sadiq. 2016. “Improving the Energy Efficiency of the Existing Building Stock: A Critical Review of Commercial and Institutional Buildings.” Renewable and Sustainable Energy Reviews 53: 1032–1045.
  • Taylor, S. August, 2018. “Making VAV Great Again.” ASHRAE Journal. http://www.taylor-engineering.com/wp-content/uploads/2020/04/ASHRAE_Journal_-_Making_VAV_Great_Again.pdf.
  • Taylor, S., B. Gill, and R. Kiriu. 2020. RP-1711: Advanced Sequences of Operation for HVAC Systems – Phase II Central Plants and Hydronic Systems. Technical Report. ASHRAE Research Project.
  • Taylor, S. November, 2015. “Resetting Setpoints Using Trim & Respond Logic.” ASHRAE Journal. https://www.taylor-engineering.com/wp-content/uploads/2020/04/ASHRAE_Journal_-_Trim_and_Respond.pdf.
  • Treado, S., and Y. Chen. 2013. “Saving Building Energy Through Advanced Control Strategies.” Energies6 (9): 4769–4785.
  • Van Rossum, G., and F. L. Drake. 2009. Python 3 Reference Manual. Scotts Valley, CA: CreateSpace.
  • Wetter, M. 2009. “Modelica-based Modelling and Simulation to Support Research and Development in Building Energy and Control Systems.” Journal of Building Performance Simulation 2: 143–161.
  • Wetter, M. 2020. “BuildingsPy: A Python Package for Simulating and Testing Models from the Modelica Buildings and IBPSA Libraries.” https://pypi.org/project/buildingspy/.
  • Wetter, M., K. Benne, A. Gautier, T. S. Nouidui, A. Ramle, A. Roth, H. Tummescheit, S. Mentzer, and C. Winther. 2020. “Lifting the Garage Door on Spawn, an Open-Source BEM-Controls Engine.” In Proceedings of Building Performance Modeling Conference and SimBuild, 518–525. Chicago, IL, September 29–October 1. https://simulationresearch.lbl.gov/wetter/download/2020-simBuild-spawn.pdf.
  • Wetter, M., P. Ehrlich, A. Gautier, M. Grahovac, P. Haves, J. Hu, A. Prakash, D. Robin, and K. Zhang. 2022. “OpenBuildingControl: Digitizing the Control Delivery from Building Energy Modeling to Specification, Implementation and Formal Verification.” Energy 238 (Part A): 121501. ISSN 0360-5442.
  • Wetter, M., P. Ehrlich, A. Gautier, M. Grahovac, P. Haves, J. Hu, and K. Zhang. 2021. Open Building Control. California Energy Commission CEC 500-2021-012, Technical Report. Lawrence Berkeley National Laboratory. https://escholarship.org/uc/item/65x9837z.
  • Wetter, M., M. Grahovac, and J. Hu. 2018. “Control Description Language.” In Proceedings of The American Modelica Conference 2018. Cambridge, MA: Somberg Conference Center, October 9–10.
  • Wetter, M., J. Hu, M. Grahovac, B. Eubanks, and P. Haves. 2018. “OpenBuildingControl: Modelling Feedback Control as a Step Towards Formal Design, Specification, Deployment and Verification of Building Control Sequences.” In 2018 Building Performance Modeling Conference and SimBuild, 775–782. Chicago, IL, September 26–28.
  • Wetter, M., W. Zuo, T. S. Nouidui, and X. Pang. 2014. “Modelica Buildings Library.” Journal of Building Performance Simulation 7: 253–270.
  • Winkelmann, F. C., B. E. Birdsall, W. F. Buhl, K. L. Ellington, A. E. Erdem, J. J. Hirsch, and S. Gates. 1993. DOE-2 Supplement. Version 2.1E. Technical Report LBL-34947. Berkeley, CA: Lawrence Berkeley National Laboratory. doi:https://doi.org/10.2172/10147851.
  • Zhou, X., N. Haberl, and H. Cheng. 2017. Demonstration of Energy Savings in Commercial Buildings for Tiered Trim and Respond Method in Resetting Static Pressure for VAV Systems. Technical Report. Iowa State University of Science and Technology.