276
Views
2
CrossRef citations to date
0
Altmetric
Research Article

A methodology and clinical dataset with ground-truth to evaluate registration accuracy quantitatively in computer-assisted Laparoscopic Liver Resection

, , , , , & show all
Pages 441-450 | Received 18 Oct 2021, Accepted 20 Oct 2021, Published online: 12 Nov 2021

References

  • Adagolodjo Y, Trivisonne R, Haouchine N, Cotin S, Courtecuisse H 2017. Silhouette-based pose estimation for deformable organs application to surgical augmented reality. In: IROS. Vancouver, BC, Canada: IEEE. p. 539–544.
  • Beasley RA, Stefansic JD, Herline AJ, Guttierez L, Galloway RL Jr. 1999. Registration of ultrasound images. In: SPIE Medical Imaging 1999: Image Display; San Diego, CA, USA; vol. 3658. p. 125–132.
  • Bernhardt S, Nicolau SA, Bartoli A, Agnus V, Soler L, Doignon C 2015. Using shading to register an intraoperative ct scan to a laparoscopic image. In: CARE. Munich, Germany: Springer. p. 59–68.
  • Boctor E, Viswanathan A, Choti M, Taylor RH, Fichtinger G, Hager G 2004. A novel closed form solution for ultrasound calibration. In: IEEE ISBI. Arlington, VA, USA. p. 527–530.
  • Bouguet JY. 2000. Matlab camera calibration toolbox. Caltech Tech Vision; [accessed 2021 Oct 29]. http://www.vision.caltech.edu/bouguetj/calib_doc/
  • Carbajal G, Lasso A, Gómez Á, Fichtinger G. 2013. Improving n-wire phantom-based freehand ultrasound calibration. IJCARS. 8(6):1063–1072.
  • Cash DM, Miga MI, Glasgow SC, Dawant BM, Clements LW, Cao Z, Galloway RL, Chapman WC. 2007. Concepts and preliminary data toward the realization of image-guided liver surgery. J Gastrointest Surg. 11(7):844–859. doi:https://doi.org/10.1007/s11605-007-0090-6.
  • Cash DM, Sinha TK, Chapman WC, Terawaki H, Dawant BM, Galloway RL, Miga MI. 2003. Incorporation of a laser range scanner into image-guided liver surgery: surface acquisition, registration, and tracking. Med Phys. 30(7):1671–1682. doi:https://doi.org/10.1118/1.1578911.
  • Cenni F, Monari D, Desloovere K, Aertbeliën E, Schless SH, Bruyninckx H. 2016. The reliability and validity of a clinical 3d freehand ultrasound system. Comput Method Prog Biomed. 136:179–187. doi:https://doi.org/10.1016/j.cmpb.2016.09.001.
  • Cheung CL, Wedlake C, Moore J, Pautler SE, Peters TM 2010. Fused video and ultrasound images for minimally invasive partial nephrectomy: a phantom study. In: MICCAI 2010. Beijing, China. p. 408–415.
  • Clements LW, Collins JA, Weis JA, Simpson AL, Adams LB, Jarnagin WR, Miga MI. 2016. Evaluation of model-based deformation correction in image-guided liver surgery via tracked intraoperative ultrasound. SPIE Med Imag. 3(1):015003. doi:https://doi.org/10.1117/1.JMI.3.1.015003.
  • Dumpuri P, Clements LW, Dawant BM, Miga MI. 2010. Model-updated image-guided liver surgery: preliminary results using surface characterization. Prog Biophys Mol Biol. 103(2–3):197–207. doi:https://doi.org/10.1016/j.pbiomolbio.2010.09.014.
  • Espinel Y, Özgür E, Calvet L, Le Roy B, Buc E, Bartoli A. 2020. Combining visual cues with interactions for 3d–2d registration in liver laparoscopy. Ann Biomed Eng. 48(6): 1–16.
  • Griwodz C, Gasparini S, Calvet L, Gurdjos P, Castan F, Maujean B, Lillo GD, Lanthony Y 2021. Alicevision Meshroom: an open-source 3D reconstruction pipeline. In: Proceedings of the 12th ACM Multimedia Systems Conference - MMSys ’21. Istanbul, Turkey: ACM Press. p. 241–247.
  • Haouchine N, Roy F, Untereiner L, Cotin S 2016. Using contours as boundary conditions for elastic registration during minimally invasive hepatic surgery. In: IROS. Daejeon, Korea. p. 495–500.
  • Hartley R, Zisserman A. 2003. Multiple view geometry in computer vision. Cambridge university press, UK.
  • Hayashi Y, Igami T, Hirose T, Nagino M, Mori K 2015. Development and clinical application of surgical navigation system for laparoscopic hepatectomy. In: SPIE Medical Imaging 2015: Image-Guided Procedures, Robotic Interventions, and Modeling; Orlando, Florida, USA. vol. 9415. p. 94151X.
  • Horn BK, Hilden HM, Negahdaripour S. 1988. Closed-form solution of absolute orientation using orthonormal matrices. JOSA A. 5(7):1127–1135. doi:https://doi.org/10.1364/JOSAA.5.001127.
  • Hsu PW, Prager RW, Gee AH, Treece GM. 2009. Freehand 3d ultrasound calibration: a review. In: Sensen C.W., Hallgrímsson B., editors. Advanced imaging in biology and medicine. Springer, Berlin, Heidelberg. p. 47–84.
  • Koo B, Özgür E, Le Roy B, Buc E, Bartoli A 2017. Deformable registration of a preoperative 3d liver volume to a laparoscopy image using contour and shading cues. In: MICCAI. Quebec City, Quebec, Canada. p. 326–334.
  • Lasso A, Heffter T, Rankin A, Pinter C, Ungi T, Fichtinger G. 2014. Plus: open-source toolkit for ultrasound-guided intervention systems. IEEE Trans Biomed Eng. 61(10):2527–2537. doi:https://doi.org/10.1109/TBME.2014.2322864.
  • Lepetit V, Moreno-Noguer F, Fua P. 2009. Epnp: an accurate o (n) solution to the pnp problem. Int J Comput Vis. 81(2):155. doi:https://doi.org/10.1007/s11263-008-0152-6.
  • Liu X, Kang S, Wilson E, Peters CA, Kane TD, Shekhar R 2014. Evaluation of electromagnetic tracking for stereoscopic augmented reality laparoscopic visualization. In: Workshop on Clinical Image-Based Procedures. Boston, MA, USA. Springer. p. 84–91.
  • Maier-Hein L, Groch A, Bartoli A, Bodenstedt S, Boissonnat G, Chang PL, Clancy N, Elson DS, Haase S, Heim E, et al. 2014. Comparative validation of single-shot optical techniques for laparoscopic 3-d surface reconstruction. IEEE Trans Med Imag. 33(10):1913–1930. doi:https://doi.org/10.1109/TMI.2014.2325607.
  • Mercier L, Langø T, Lindseth F, Collins DL. 2005. A review of calibration techniques for freehand 3-d ultrasound systems. Ultrasound Med Biol. 31(4):449–471. doi:https://doi.org/10.1016/j.ultrasmedbio.2004.11.015.
  • Modrzejewski R, Collins T, Seeliger B, Bartoli A, Hostettler A, Marescaux J. 2019. An in vivo porcine dataset and evaluation methodology to measure soft-body laparoscopic liver registration accuracy with an extended algorithm that handles collisions. IJCARS. 14(7):1237–1245.
  • Ogilvie JF. 1984. A monte-carlo approach to error propagation. Comput Chem. 8(3):205–207. doi:https://doi.org/10.1016/0097-8485(84)80007-8.
  • Plantefève R, Peterlik I, Haouchine N, Cotin S. 2016. Patient-specific biomechanical modeling for guidance during minimally-invasive hepatic surgery. Ann Biomed Eng. 44(1):139–153. doi:https://doi.org/10.1007/s10439-015-1419-z.
  • Poon TC, Rohling RN. 2005. Comparison of calibration methods for spatial tracking of a 3-d ultrasound probe. Ultrasound Med Biol. 31(8):1095–1108. doi:https://doi.org/10.1016/j.ultrasmedbio.2005.04.003.
  • Poulin F, Amiot LP. 2002. Interference during the use of an electromagnetic tracking system under or conditions. J Biomech. 35(6):733–737. doi:https://doi.org/10.1016/S0021-9290(02)00036-2.
  • Robu MR, Ramalhinho J, Thompson S, Gurusamy K, Davidson B, Hawkes D, Stoyanov D, Clarkson MJ. 2018. Global rigid registration of ct to video in laparoscopic liver surgery. IJCARS. 13(6):947–956.
  • Suwelack S, Röhl S, Bodenstedt S, Reichard D, Dillmann R, Dos Santos T, Maier-Hein L, Wagner M, Wünscher J, Kenngott H, et al. 2014. Physics-based shape matching for intraoperative image guidance. Med Phys. 41(11):111901. doi:https://doi.org/10.1118/1.4896021.
  • Thompson S, Schneider C, Bosi M, Gurusamy K, Ourselin S, Davidson B, Hawkes D, Clarkson MJ. 2018. In vivo estimation of target registration errors during augmented reality laparoscopic surgery. IJCARS. 13(6):865–874.
  • Wang L, Wang T, Liu H, Hu L, Han Z, Liu W, Guo N, Qi Y, Xu Y. 2018. An automated calibration method of ultrasonic probe based on coherent point drift algorithm. IEEE Access. 6:8657–8665. doi:https://doi.org/10.1109/ACCESS.2018.2791582.
  • Wilks SS. 1960. Multidimensional statistical scatter. Contrib Probab Stat. 1:486–503.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.