References
- Charalambous, C. A., Wang, Z. D., Jarman, P., & Sturgess, J. P. (2011). Frequency domain analysis of a power transformer experiencing sustained ferroresonance. IET Generation, Transmission & Distribution, 5, 640–649.10.1049/iet-gtd.2010.0233
- Corea-Araujo, J. A., González-Molina, F., Martínez, J. A., Barrado-Rodrigo, J. A., & Guasch-Pesquer, L. (2014). Tools for characterization and assessment of ferroresonance using 3-D bifurcation diagrams. IEEE Transactions on Power Delivery, 29, 2543–2551.10.1109/TPWRD.2014.2320599
- Ferracci, P. (1998). Ferroresonance. Retrieved from https://www.ops-ecat.schneider-electric.com/
- Frame, J. G., Mohan, N., & Liu, T. (1982). Hysteresis modeling in an electro-magnetic transients program. IEEE Transactions, PAS-101, 3403–3411.
- Graovac, M., Iravani, R., Wang, X., & McTaggart, R. D. (2003). Fast ferroresonance suppression of coupling capacitor voltage transformers. IEEE Transactions on Power Delivery, 18, 158–163.10.1109/TPWRD.2002.803837
- Iravani, M. R., Chaudhary, A. K. S., Giesbrecht, W. J., Hassan, I. E., Keri, A. J. F., Lee, K. C., … Woodford, D. A. (2000). Modeling and analysis guidelines for slow transients. III. The study of ferroresonance. IEEE Transactions on Power Delivery, 15, 255–265.10.1109/61.847260
- Jacobson, D. (2003). Examples of ferroresonance in a high voltage power system. In Proceedings of 2003 IEEE power engineering society general meeting (pp. 1206–1212).
- Jazebi, P., Farazmand, A., Murali, B. P., & Leon, F. D. (2013). A comparative study on π and T equivalent models for the analysis of transformer ferroresonance. IEEE Transactions on Power Delivery, 28, 526–528.10.1109/TPWRD.2012.2220637
- Jiles, D. C., & Atherton, D. L. (1986). Theory of ferromagnetic hysteresis. Journal of Magnetism and Magnetic Materials, 61, 48–60.10.1016/0304-8853(86)90066-1
- Leon, F. D., Farazmand, A., & Joseph, P. (2012). Comparing the T and π equivalent circuits for the calculation of transformer inrush currents. IEEE Transactions on Power Delivery, 27, 2390–2398.10.1109/TPWRD.2012.2208229
- Liu, Z., Han, M., Tang, P., & Liu, Z. (2006). Discussion and practice of eliminating the ferromagnetic resonance in electromagnetic voltage transformer. High Voltage Apparatus, 42, 317–318.
- Marti, J. R., & Soudack, A. C. (1991). Ferroresonance in power systems: Fundamental solutions. IEE Proceedings C – Generation, Transmission and Distribution, 138, 321–329.10.1049/ip-c.1991.0040
- Martinez, J. A., & Mork, B. A. (2005). Transformer modeling for low- and mid-frequency transients – A review. IEEE Transactions on Power Delivery, 20, 1625–1632.10.1109/TPWRD.2004.833884
- Mork, B. A., & Stuehm, D. L. (1994). Application of nonlinear dynamics and chaos to ferroresonance in distribution systems. IEEE Transactions on Power Delivery, 9, 1009–1017.10.1109/61.296285
- Radmanesh, H., Heidary, A., Fathi, S. H., & Gharehpetian, G. B. (2016). Dual function ferroresonance and fault current limiter based on DC reactor. IET Generation, Transmission & Distribution, 10, 2058–2065.10.1049/iet-gtd.2015.1032
- Rezaei-Zare, A., & Iravani, R. (2013). Electromagnetic transients in transformer and rotating machine windings. Hershey, PA: IGI Global.10.4018/978-1-4666-1921-0
- Sima, W., Yang, M., Yang, Q., Yuan, T., & Zou, M. (2014). Simulation and experiment on a flexible control method for ferroresonance. IET Generation, Transmission & Distribution, 8, 1744–1753.10.1049/iet-gtd.2014.0046
- Smith, D. R., Swanson, S. R., and Borst, J. D. (1975). Overvoltages with remotely-switched cable-fed grounded wye-wye transformers. IEEE Transactions on Power Apparatus and Systems, 94, 1843–1853.10.1109/T-PAS.1975.32030
- Tokić, A., & Smajić, J. (2015). Modeling and simulations of ferroresonance by using BDF/NDF numerical methods. IEEE Transactions on Power Delivery, 30, 342–350.10.1109/TPWRD.2014.2346766
- Valverde, V., Mazón, A. J., Zamora, I., & Buigues, G. (2007). Ferroresonance in voltage transformers: Analysis and simulations. International Conference on Renewable Energies and Power Quality, Sevilla, Spain.
- Xie, G. (1985). Overvoltage in power systems. Wuhan: China Water & Power Press.
- Zhou, M., & Sun, Y. (2015). Eliminating ferro-resonance for distribution network with different neutral grounding modes. High Voltage Apparatus, 51, 80–85.