Research challenges and directions in HVAC fault prevalence

, , , , , , & show all

References

  • ADM Associates, Inc. 2009. \\chenas03.cadmus.com\SmartEdit\WatchFolder\XML_Signal_to_CCE_High_Speed_WF\ESA\IN\INPROCESS\1. Market Assessment and Field M&V Study for Comprehensive Packaged A/C Systems Program. No. SCE0286.01. Southern California Edison Company. http://www.calmac.org/publications/CPACS_Assessment_Final_Report_7-24-09.pdf.
  • Ardehali, M. M., T. F. Smith, J. M. House, and C. J. Klaassen. 2003. Building energy use and control problems: an assessment of case studies. ASHRAE Transactions 109:111–21.
  • Behfar, A., D. Yuill, and Y. Yu. 2018. Supermarket system characteristics and operating faults (RP-1615). Science and Technology for the Built Environment 24 (10):1104–13. doi:10.1080/23744731.2018.1479614
  • Braun, J. E. 2003. Automated fault detection and diagnostics for vapor compression cooling equipment. Journal of Solar Energy Engineering 125 (3):266–74. doi:10.1115/1.1591001
  • Breuker, M. S., and J. E. Braun. 1998. Common faults and their impacts for rooftop air conditioners. HVAC&R Research 4 (3):303–18. doi:10.1080/10789669.1998.10391406
  • Breuker, M., T. Rossi, and J. Braun. 2000. Smart maintenance for rooftop units. ASHRAE Journal 42 (11):41–47.
  • Close, B. 2010. HVAC energy efficiency maintenance study (CALMAC Study ID SCE0293.01), Southern California Edison. http://www.calmac.org/publications/HVAC_EE_Maintenance_Final.pdf
  • Codes and Standards Enhancement (CASE). 2011. Draft Measure Information Template – Light Commercial Unitary HVAC (p. 186). California Statewide Utility Codes and Standards Program. http://www.h-m-g.com/T24/NonresHVAC/2013_CASE_HVAC%20Controls%20and%20Economizing_03302011.pdf
  • Comstock, M., and J. E. Braun. 1999. Literature Review for Application of Fault Detection and Diagnostic Methods to Vapor Compression Cooling Equipment. No. #4036-2. p. 86. ASHRAE Deliverable for Research Project 1043-RP Fault Detection and Diagnostic (FDD) Requirements and Evaluation Tools for Chillers.
  • Comstock, M., J. E. Braun, and E. A. Groll. 2002. A survey of common faults in chillers. ASHRAE Transactions 108(1):819–825.
  • Cowan, A. 2004. Review of Recent Commercial Roof Top Unit Field Studies in the Pacific Northwest and California. New Buildings Institute. Prepared for Northwest Power and Conservation Council and Regional Technical Forum. https://newbuildings.org/sites/default/files/NWPCC_SmallHVAC_Report_R3_.pdf.
  • Davis, R., D. Baylon, R. Hart, and E. Water. 2002. Identifying energy savings potential on rooftop commercial units. In Proc. ACEEE Summer Study on Energy Efficiency in Buildings. https://aceee.org/files/proceedings/2002/data/papers/SS02_Panel3_Paper07.pdf.
  • Davis, R., P. Francisco, M. Kennedy, D. Baylon, and B. Manclark. 2002. Enhanced Operations & Maintenance Procedures for Small Packaged Rooftop HVAC Systems. http://www.ecotope.com/wp/wp-content/uploads/2014/07/2002_002_EnhancedOperationsMaintenance.pdf
  • Dey, D., and B. Dong. 2016. A probabilistic approach to diagnose faults of air handling units in buildings. Energy and Buildings 130:177–87. doi:10.1016/j.enbuild.2016.08.017
  • Djunaedy, E., K. van den Wymelenberg, B. Acker, and H. Thimmana. 2011. Oversizing of HVAC system: Signatures and penalties. Energy and Buildings 43 (2–3):468–75. https://www.sciencedirect.com/science/article/pii/S0378778810003634. doi:10.1016/j.enbuild.2010.10.011
  • Downey, T., and J. Proctor. 2002. “What Can 13,000 Air Conditioners Tell Us?” ACEEE Summer Study Proceedings, 1:16. https://aceee.org/files/proceedings/2002/data/papers/SS02_Panel1_Paper05.pdf.
  • Emmerich, S. J., T. McDowell, and W. Anis. 2005. Investigation of the impact of commercial building envelope airtightness on HVAC energy use. No. NIST IR 7238. Gaithersburg, MD: National Institute of Standards and Technology. https://www.nist.gov/publications/investigation-impact-commercial-building-envelope-airtightness-hvac-energy-use-0.
  • Energy Information Administration. 2002. Commercial Buildings Energy Consumption Survey.
  • Energy Information Administration. 2017. “Energy Consumption Estimates by End-Use Sector, Ranked by State.” https://www.eia.gov/state/seds/sep_sum/html/rank_use.html.
  • Energy Market Innovations, Inc. 2004. Small Commercial HVAC Pilot Program. No. #E04-135. Northwest Energy Efficiency Alliance.
  • Farahmand, F.,. C. Chappell, and H. Weitze. 2017. Economizer Fault Detection and Diagnostics (FDD) for Built-Up Air Handlers – Final Report. No. 2019- NR-MECH2- F. Codes and Standards Enhancement (CASE) Initiative 2019 California Building Energy Efficiency Standards.
  • Felts, D. R., and P. Bailey. 2000. “The State of Affairs—Packaged Cooling Equipment in California.” In Proceedings from ACEEE Summer Studies on Energy Efficiency in Buildings.
  • Frank, S., G. Lin, X. Jin, R. Singla, A. Farthing, and J. Granderson. 2019. A performance evaluation framework for building fault detection and diagnosis algorithms. Energy and Buildings 192:84–92. doi:10.1016/j.enbuild.2019.03.024
  • Gage, C., and G. Troy. 1998. Reducing refrigerant emissions from supermarket systems. ASHRAE Journal 40(11):32.
  • Goetzler, W., R. Shandross, J. Young, O. Petritchenko, D. Ringo, and S. McClive. 2017. Energy Savings Potential and RD&D Opportunities for Commercial Building HVAC Systems No. DOE/EE-1703. Navigant Consulting, Burlington, MA. https://www.energy.gov/sites/prod/files/2017/12/f46/bto-DOE-Comm-HVAC-Report-12-21-17.pdf.
  • Granderson, J., R. Singla, E. Mayhorn, P. Ehrlich, D. Vrabie, and S. Frank. 2017. Characterization and Survey of Automated Fault Detection and Diagnostics Tools. No. LBNL-2001075. Lawrence Berkeley National Laboratory. https://eta-publications.lbl.gov/sites/default/files/lbnl-2001075.pdf.
  • Gunay, H. B., W. Shen, and C. Yang. 2019. Text-mining building maintenance work orders for component fault frequency. Building Research & Information 47 (5):518–33. https://www.tandfonline.com/doi/abs/10.1080/09613218.2018.1459004.
  • Heinemeier, K. 2012. Rooftop HVAC Fault Detection and Diagnostics: Technology and Market Review/Energy and Demand Savings Estimates. No. CEC PIER #500-08-049.
  • Hewett, M., D. Bohac, R. Landry, T. Dunsworth, S. Englander, and G. Peterson. 1992. Measured Energy and Demand Impacts of Efficiency Tune-Ups for Small Commercial Cooling Systems.” in ACEEE Conference Proceedings. https://aceee.org/files/proceedings/1992/data/papers/SS92_Panel3_Paper14.pdf.
  • Hodgkins, K. 2018. August 31. “Fitbit Data Mining Identifies Some Surprising Trends in Resting Heart Rate.”
  • Hunt, M., K. Heinemeier, M. Hoeschele, and E. Weitzel. 2010. HVAC Energy Efficiency Maintenance Study. Davis Energy Group; UC Davis; WCEC. http://www.calmac.org/%5C/publications/HVAC_EE_Maintenance_Final.pdf
  • Hyvärinen, J., and S. Karki, eds. 1996. Building optimization and fault diagnosis source book. Espoo: VTT Building Technology.
  • ICC. 2012. International Energy Conversion Code (IECC), International Code Council (ICC) Inc. Falls Church, VA
  • Jacobs, P. 2002. Anticipating economizer failure during small-packaged system installation. HPAC Engineering 74 (9):4.
  • Jacobs, P. 2003. Small HVAC Problems and Potential Savings Reports (No. 500- 03- 082- A-25). California Energy Commission.
  • Katipamula, S. 2017. Improving Commercial Building Operations thru Building Re-tuning: Meta-Analysis. Pacific Northwest National Laboratory. https://buildingretuning.pnnl.gov/documents/pnnl_sa_110686.pdf.
  • Katipamula, S., and M. R. Brambley. 2005a. Review article: methods for fault detection, diagnostics, and prognostics for building systems—a review, Part I. HVAC&R Research 11 (1):3–25. doi:10.1080/10789669.2005.10391123
  • Katipamula, S., and M. R. Brambley. 2005b. Review article: methods for fault detection, diagnostics, and prognostics for building systems—a review, Part II. HVAC&R Research 11 (2):169–87. doi:10.1080/10789669.2005.10391133
  • Kim, W., and S. Katipamula. 2018. A review of fault detection and diagnostics methods for building systems. Science and Technology for the Built Environment 24 (1):3–21. https://www.tandfonline.com/doi/full/10.1080/23744731.2017.1318008. doi:10.1080/23744731.2017.1318008
  • Kramer, H., G. Lin, C. Curtin, E. Crowe, and J. Granderson. 2020. Building analytics and monitoring-based commissioning: Industry practice, costs, and savings. Energy Efficiency 13 (3):537–49. doi:10.1007/s12053-019-09790-2
  • Lazer, D., R. Kennedy, G. King, and A. Vespignani. 2014. Big data. The parable of Google Flu: traps in big data analysis. Science (New York, N.Y.) 343 (6176):1203–5. doi:10.1126/science.1248506
  • Li, Y., and Z. O’Neill. 2018. A critical review of fault modeling of HVAC systems in buildings. Building Simulation 11 (5):953–75. doi:10.1007/s12273-018-0458-4
  • Lin, G., H. Kramer, and J. Granderson. 2020. Building fault detection and diagnostics: Achieved savings, and methods to evaluate algorithm performance. Building and Environment 168:106505. https://www.sciencedirect.com/science/article/pii/S0360132319307176. doi:10.1016/j.buildenv.2019.106505
  • Liu, M., A. Athar, Y. Zhu, and D. E. Claridge. 1995. Reduce Building Energy Consumption by Improving the Supply Air Temperature Schedule and Recommissioning the Terminal Boxes. No. ESL-TR-95/01-04. Energy Management and Operations Division at the M D. Anderson Cancer Center.
  • Madani, H. 2014. The common and costly faults in heat pump systems. Energy Procedia 61:1803–1806.
  • Mills, E. 2011. Building commissioning: A golden opportunity for reducing energy costs and greenhouse gas emissions in the United States. Energy Efficiency 4 (2):145–73. doi:10.1007/s12053-011-9116-8
  • Mowris, R. 2006. Evaluation Measurement And Verification Of Air Conditioner Quality Maintenance Measures. No. CPUC Reference Numbers 1385-04, 1395-04 and 1437–04. Aloha Systems, Inc.
  • Mowris, R., A. Blankenship, E. Jones, and R. Mowris. 2004. Field measurements of air conditioners with and without TXVs. ACEEE Summer Study Proceedings 1:16.
  • Qin, J., and S. Wang. 2005. A fault detection and diagnosis strategy of VAV air-conditioning systems for improved energy and control performances. Energy and Buildings 37 (10):1035–48. doi:10.1016/j.enbuild.2004.12.011
  • Roth, K. W., D. Westphalen, P. Llana, and M. Feng. 2004. “The Energy Impact of Faults in U.S. Commercial Buildings.” p. 9. Presented at the International Refrigeration and Air Conditioning Conference.
  • Roth, K. W., Westphalen, D. M. Y. Feng, P. and Llana, L. Quartararo. 2005. Energy Impact of Commercial Building Controls and Performance Diagnostics: Market Characterization, Energy Impact of Building Faults and Energy Savings Potential. No. D0180. TIAX.
  • Salathé, M., L. Bengtsson, T. J. Bodnar, D. D. Brewer, J. S. Brownstein, C. Buckee, E. M. Campbell, C. Cattuto, S. Khandelwal, P. L. Mabry, et al. 2012. Digital epidemiology. PLoS Computational Biology 8 (7):e1002616 doi:10.1371/journal.pcbi.1002616
  • Sharma, A. B., L. Golubchik, and R. Govindan. 2010. Sensor faults: Detection methods and prevalence in real-world datasets. ACM Transactions on Sensor Networks 6 (3):1–39. doi:10.1145/1754414.1754419
  • Shoukas, G., M. Bianchi, and, and M. Deru. 2020. Analysis of Fault Data Collected from Automated Fault Detection and Diagnostic Products for Packaged Rooftop Units. No. NREL/TP-5500-77077. National Renewable Energy Lab.(NREL), Golden, CO (United States).
  • Smart Energy Analytics Campaign 2019. https://smart-energy-analytics.org/.
  • Stouppe, D. E., and T. Y. S. Lau. 1989. Air conditioning and refrigeration equipment failures. The National Engineer 93 (9):14–7.
  • Von Neida, B., D. Maniccia, and A. Tweed. 2001. An analysis of the energy and cost savings potential of occupancy sensors for commercial lighting systems. Journal of the Illuminating Engineering Society 30 (2):111–25. doi:10.1080/00994480.2001.10748357
  • Wen, J., and S. Li. 2011. Tools for Evaluating Fault Detection and Diagnostic Methods for Air-Handling Units. ASHRAE 1312-RP.
  • Yuill, D. P., and J. E. Braun. 2013. Evaluating the performance of fault detection and diagnostics protocols applied to air-cooled unitary air-conditioning equipment. HVAC&R Research 19 (7):882–91. doi:10.1080/10789669.2013.808135
  • Zhao, Y., J. Wen, F. Xiao, X. Yang, and S. Wang. 2017. Diagnostic Bayesian networks for diagnosing air handling units faults – part I: Faults in dampers, fans, filters and sensors. Applied Thermal Engineering 111:1272–86. doi:10.1016/j.applthermaleng.2015.09.121

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.