References
- Abd El-Baky, M. A., and M. M. Mohamed. 2007. Heat pipe heat exchanger for heat recovery in air conditioning. Applied Thermal Engineering 27 (4):795–801. doi:https://doi.org/10.1016/j.applthermaleng.2006.10.020
- Ahmadzadehtalatapeh, M., and Y. H. Yau. 2011. The application of heat pipe heat exchangers to improve the air quality and reduce the energy consumption of the air conditioning system in a hospital ward—A full year model simulation. Energy and Buildings 43 (9):2344–55. doi:https://doi.org/10.1016/j.enbuild.2011.05.021
- Burlacu, A., G. Sosoi, R. Ș. Vizitiu, M. Bărbuță, C. D. Lăzărescu, V. Ciocan, and A. A. Șerbănoiu. 2018. Energy efficient heat pipe heat exchanger for waste heat recovery in buildings. Procedia Manufacturing 22:714–21. doi:https://doi.org/10.1016/j.promfg.2018.03.103
- Deng, Y., Z. Quan, Y. Zhao, and L. Wang. 2013. Experimental investigations on the heat transfer characteristics of micro heat pipe array applied to flat plate solar collector. Science China Technological Sciences 56 (5):1177–85. doi:https://doi.org/10.1007/s11431-013-5204-7
- Deng, Y., Y. Zhao, Z. Quan, and T. Zhu. 2015. Experimental study of the thermal performance for the novel flat plate solar water heater with micro heat pipe array absorber. Energy Procedia 70:41–8. doi:https://doi.org/10.1016/j.egypro.2015.02.095
- Diao, Y. H., L. Liang, Y. M. Kang, Y. H. Zhao, Z. Y. Wang, and T. T. Zhu. 2017. Experimental study on the heat recovery characteristic of a heat exchanger based on a flat micro-heat pipe array for the ventilation of residential buildings. Energy and Buildings 152:448–57. doi:https://doi.org/10.1016/j.enbuild.2017.07.045
- Diao, Y., J. Zhang, W. Yu, and Y. Zhao. 2014. Experimental study on the heat recovery characteristic of a plate heat pipe heat exchanger in room ventilation. HVAC&R Research 20 (7):828–35. doi:https://doi.org/10.1080/10789669.2014.945852
- Ismail, M. F., M. O. Reza, M. A. Zobaer, and M. Ali. 2013. Numerical investigation of turbulent heat convection from solid and longitudinally perforated rectangular fins. Procedia Engineering 56:497–502. doi:https://doi.org/10.1016/j.proeng.2013.03.152
- Jouhara, H., A. Chauhan, T. Nannou, S. Almahmoud, B. Delpech, and L. C. Wrobel. 2017. Heat pipe based systems—Advances and applications. Energy 128:729–54. doi:https://doi.org/10.1016/j.energy.2017.04.028
- Kanargi, B., P. S. Lee, and C. Yap. 2018. A numerical and experimental investigation of heat transfer and fluid flow characteristics of an air-cooled oblique-finned heat sink. International Journal of Heat and Mass Transfer 116:393–416. doi:https://doi.org/10.1016/j.ijheatmasstransfer.2017.09.013
- Kanargi, O. B., P. S. Lee, and C. Yap. 2017. A numerical and experimental investigation of heat transfer and fluid flow characteristics of a cross-connected alternating converging–diverging channel heat sink. International Journal of Heat and Mass Transfer 106:449–64. doi:https://doi.org/10.1016/j.ijheatmasstransfer.2016.08.057
- Kircher, K., X. Shi, S. Patil, and K. M. Zhang. 2010. Cleanroom energy efficiency strategies: Modeling and simulation. Energy and Buildings 42 (3):282–9. doi:https://doi.org/10.1016/j.enbuild.2009.09.004
- Li, G., G. Zhang, W. He, J. Ji, S. Lv, X. Chen, and H. Chen. 2016. Performance analysis on a solar concentrating thermoelectric generator using the micro-channel heat pipe array. Energy Conversion and Management 112:191–8. doi:https://doi.org/10.1016/j.enconman.2016.01.025
- Liang, C., S. Jiang, X. Shao, H. Wang, S. Yan, Z. Yang, and X. Li. 2021. Is it safe to reopen theaters during the COVID-19 pandemic? Frontiers in Built Environment 7:1–17. doi:https://doi.org/10.3389/fbuil.2021.637277
- Lin, S., J. Broadbent, and R. McGlen. 2005. Numerical study of heat pipe application in heat recovery systems. Applied Thermal Engineering 25 (1):127–33. doi:https://doi.org/10.1016/j.applthermaleng.2004.02.012
- Loomans, M. G. L. C., T. B. J. Ludlage, H. van den Oever, P. C. A. Molenaar, H. S. M. Kort, and P. H. J. Joosten. 2020. Experimental investigation into cleanroom contamination build-up when applying reduced ventilation and pressure hierarchy conditions as part of demand controlled filtration. Building and Environment 176:106861. doi:https://doi.org/10.1016/j.buildenv.2020.106861
- Loomans, M. G. L. C., P. C. A. Molenaar, H. S. M. Kort, and P. H. J. Joosten. 2019. Energy demand reduction in pharmaceutical cleanrooms through optimization of ventilation. Energy and Buildings 202:109346. doi:https://doi.org/10.1016/j.enbuild.2019.109346
- Mardiana-Idayu, A., and S. B. Riffat. 2011. An experimental study on the performance of enthalpy recovery system for building applications. Energy and Buildings 43 (9):2533–8. doi:https://doi.org/10.1016/j.enbuild.2011.06.009
- Noie-Baghban, S. H., and G. R. Majideian. 2000. Waste heat recovery using heat pipe heat exchanger (HPHE) for surgery rooms in hospitals. Applied Thermal Engineering 20 (14):1271–82. doi:https://doi.org/10.1016/S1359-4311(99)00092-7
- Opoku, R., C. K. K. Sekyere, S. Ackumey, O. Y. W. Abotsi, and J. P. Kizito. 2020. Exergoeconomic analysis of staggered tube cross-flow heat recovery unit incorporated into industrial air-compressor for process water heating. Energy Conversion and Management: X 7:100055. doi:https://doi.org/10.1016/j.ecmx.2020.100055
- Roulet, C. A., F. D. Heidt, F. Foradini, and M. C. Pibiri. 2001. Real heat recovery with air handling units. Energy and Buildings 33 (5):495–502. https://doi.org/https://doi.org/10.1016/S0378-7788. (00)00104-3 doi:https://doi.org/10.1016/S0378-7788(00)00104-3
- Shao, L., S. B. Riffat, and G. Gan. 1998. Heat recovery with low pressure loss for natural ventilation. Energy and Buildings 28 (2):179–84. doi:https://doi.org/10.1016/S0378-7788(98)00016-4
- Sobhan, C. B., R. L. Rag, and G. P. Peterson. 2007. A review and comparative study of the investigations on micro heat pipes. International Journal of Energy Research 31 (6-7):664–88. doi:https://doi.org/10.1002/er.1285
- Srimuang, W., and P. Amatachaya. 2012. A review of the applications of heat pipe heat exchangers for heat recovery. Renewable and Sustainable Energy Reviews 16 (6):4303–15. doi:https://doi.org/10.1016/j.rser.2012.03.030
- Wang, Y. C., and W. Q. Wu. 2004. Numerical simulation of flow around blunt bodies using RNG k-ε turbulence model. Journal of University of Shanghai for Science and Technology 6:519–23.
- Wang, Z. Y., Y. H. Diao, L. Liang, Y. H. Zhao, T. T. Zhu, and F. W. Bai. 2017. Experimental study on an integrated collector storage solar air heater based on flat micro-heat pipe arrays. Energy and Buildings 152:615–28. doi:https://doi.org/10.1016/j.enbuild.2017.07.069
- Xu, Y., H. Fan, and B. Shao. 2020. Experimental and numerical investigations on heat transfer and fluid flow characteristics of integrated U-shape micro heat pipe array with rectangular pin fins. Applied Thermal Engineering 168:114640. doi:https://doi.org/10.1016/j.applthermaleng.2019.114640
- Yan, D., T. Hong, B. Dong, A. Mahdavi, S. D’Oca, I. Gaetani, and X. Feng. 2017. IEA EBC Annex 66: Definition and simulation of occupant behavior in buildings. Energy and Buildings 156:258–70. doi:https://doi.org/10.1016/j.enbuild.2017.09.084
- Yang, F., X. Yuan, and G. Lin. 2003. Waste heat recovery using heat pipe heat exchanger for heating automobile using exhaust gas. Applied Thermal Engineering 23 (3):367–72. doi:https://doi.org/10.1016/S1359-4311(02)00190-4
- Yang, Z., A. Ghahramani, and B. Becerik-Gerber. 2016. Building occupancy diversity and HVAC (heating, ventilation, and air conditioning) system energy efficiency. Energy 109:641–9. doi:https://doi.org/10.1016/j.energy.2016.04.099
- Yau, Y. H., and M. Ahmadzadehtalatapeh. 2011. Predicting yearly energy recovery and dehumidification enhancement with a heat pipe heat exchanger using typical meteorological year data in the tropics. Journal of Mechanical Science and Technology 25 (4):847–53. doi:https://doi.org/10.1007/s12206-011-0213-6
- Ye, X., Y. Zhao, and Z. Quan. 2018. Experimental study on heat dissipation for lithium-ion battery based on micro heat pipe array (MHPA). Applied Thermal Engineering 130:74–82. doi:https://doi.org/10.1016/j.applthermaleng.2017.10.141
- Yeom, T., T. Simon, T. Zhang, M. Zhang, M. North, and T. Cui. 2016. Enhanced heat transfer of heat sink channels with micro pin fin roughened walls. International Journal of Heat and Mass Transfer 92:617–27. doi:https://doi.org/10.1016/j.ijheatmasstransfer.2015.09.014
- Zeng, C., S. Liu, and A. Shukla. 2017. A review on the air-to-air heat and mass exchanger technologies for building applications. Renewable and Sustainable Energy Reviews 75:753–74. doi:https://doi.org/10.1016/j.rser.2016.11.052
- Zhang, L., Y. Jiang, J. Dong, and Y. Yao. 2018. Advances in vapor compression air source heat pump system in cold regions: A review. Renewable and Sustainable Energy Reviews 81:353–65. doi:https://doi.org/10.1016/j.rser.2017.08.009
- Zhao, Y., H. Wang, Y. Diao, X. Wang, and Y. Deng. 2011. Heat transfer characteristics of flat micro-heat pipe array. Huagong Xuebao/CIESC Journal 62:336–43.
- Zhou, F., W. Duan, and G. Ma. 2017. Thermal performance of a pump-driven loop heat pipe as an air-to-air energy recovery device. Energy and Buildings 151:206–16. doi:https://doi.org/10.1016/j.enbuild.2017.06.057
- Zhu, Z., H. Fan, and C. Zhang. 2016. Experimental investigations on the effectiveness of micro heat pipe array heat exchanger for heat recovery for residential building. Applied Thermal Engineering 102:980–8. doi:https://doi.org/10.1016/j.applthermaleng.2016.03.084