References

  • Adebayo, I., D. Aborisade, and O. Yinka. 2020. A comparative analysis of SIMC-PID with other conventional techniques for automobile vehicle air conditioning system control. Journal of Scientific Research and Reports 26 (11):27–38. doi:10.9734/jsrr/2020/v26i1130333
  • Al-Khayat, R. H., A. W. A. Al-Fatlawi, M. A. Sadiq Al-Baghdadi, and M. Al-Waily. 2022. Water hammer phenomenon in pumping stations: A stability investigation based on root locus. Open Engineering 12 (1):254–62. doi:10.1515/eng-2022-0029
  • Almabrok, A., M. Psarakis, and A. Dounis. 2018. Fast tuning of the PID controller in an HVAC system using the big bang–big crunch algorithm and FPGA technology. Algorithms 11 (10):146. doi:10.3390/a11100146
  • Barwig, F. E. J. M. House, C. J. Klaassen, M. M. Ardehali, and T. F. Smith. 2002. The national building controls information program. In Proc. ACEEE summer study on energy efficiency in buildings.
  • Chintala, R., C. Price, S. Liang, and B. P. Rasmussen. 2015. Identification and elimination of hunting behavior in HVAC systems. ASHRAE Transactions 121:294–305.
  • Dincel, E, and M. T. Söylemez. 2016. Limitations on dominant pole pair selection with continuous PI and PID controllers. In Proc. IEEE International Conference on Control, Decision and Information Technologies (CoDIT), 741–45.
  • Evans, W. R. 1948. Graphical analysis of control systems. Transactions of the American Institute of Electrical Engineers 67 (1):547–51. doi:10.1109/T-AIEE.1948.5059708
  • Flower, J. O., and C. G. Hodge. 2004. Stability and transient-behavioural assessment of power-electronics-based dc-distribution systems: Part 1: The root-locus technique. Journal of Marine Engineering & Technology 3 (2):13–21. doi:10.1080/20464177.2004.11020180
  • Lachi, M., N. El Wakil, and J. Padet. 1997. The time constant of double pipe and one pass shell-and-tube heat exchangers in the case of varying fluid flow rates. International Journal of Heat and Mass Transfer 40 (9):2067–79. doi:10.1016/S0017-9310(96)00274-8
  • Mei, L., and G. J. Levermore. 2002. Simulation and validation of a VAV system with an ANN fan model and a non-linear VAV box model. Building and Environment 37 (3):277–84. doi:10.1016/S0360-1323(01)00028-2
  • Moradi, H., M. Saffar-Avval, and F. Bakhtiari-Nejad. 2011. Nonlinear multivariable control and performance analysis of an air-handling unit. Energy and Buildings 43 (4):805–13. doi:10.1016/j.enbuild.2010.11.022
  • Mulligan, J. H. 1949. The effect of pole and zero locations on the transient response of linear dynamic systems. Proceedings of the IRE, 37: 516–29.
  • Nassif, N. 2010. Performance analysis of supply and return fans for HVAC systems under different operating strategies of economizer dampers. Energy and Buildings 42 (7):1026–37. doi:10.1016/j.enbuild.2010.01.015
  • Nise, N. S. 2019. Control systems engineering. 8th ed. Hoboken, NJ: Wiley.
  • O’Neill, Z., Y. Li, and K. Williams. 2017. HVAC control loop performance assessment: A critical review (1587-RP). Science and Technology for the Built Environment 23 (4):619–36. doi:10.1080/23744731.2016.1239466
  • Pérez Lombard, L., J. Ortiz, and C. Pout. 2008. A review on buildings energy consumption information. Energy and Buildings 40 (3):394–8. doi:10.1016/j.enbuild.2007.03.007
  • Price, C. R. 2018. Cascaded Control for Improved Building HVAC Performance. Doctoral dissertation, Texas A & M University, TX.
  • Price, C., S. Liang, and B. Rasmussen. 2015. HVAC nonlinearity compensation using cascaded control architectures. ASHRAE Transactions 121:217.
  • Singhal, A., and T. I. Salsbury. 2007. Characterization and cancellation of static nonlinearity in HVAC systems. ASHRAE Transactions 113.
  • Underwood, C. P. 2002. HVAC control systems: Modelling, analysis and design. Great Britain, London: Routledge.
  • Wang, G., and Z. Han. 2019. Investigation of the accuracy of VFD analog output data and the energy performance of different voltage controls in a VFD-motor-belt-fan system. Energy and Buildings 194:260–72. doi:10.1016/j.enbuild.2019.04.008
  • Wang, G., L. Song, and K. Phalak. 2015. Investigation of the fan energy and control performance of different damper control strategies in air handling units. ASHRAE Transactions 121:110–22.
  • Wang, Q., Z. Zhang, K. J. Astrom, Y. Zhang, and Y. Zhang. 2009. Guaranteed dominant pole placement with PID controllers. Journal of Process Control 19 (2):349–52. doi:10.1016/j.jprocont.2008.04.012

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.