108
Views
1
CrossRef citations to date
0
Altmetric
Articles

How bedside feedback improves head-of-bed angle compliance for intubated patients

Pages 73-80 | Received 01 Feb 2016, Accepted 01 Jan 2017, Published online: 08 May 2017

References

  • American Thoracic Society. (2006) Guidelines for the management of adults with hospital-acquired, ventilator-associated, and healthcare-associated pneumonia. American Journal of Respiratory and Critical Care Medicine, 171, 388–416.
  • Balonov, K., Miller, A. D., Lisbon, A., and Kaynar, A. M. (2007) A novel method of continuous measurement of head of bed elevation in ventilated patients. Intensive Care Medicine, 33(6), 1050–1054.
  • Berenholtz, S. M., Pham, J. C., Thompson, D. A., Needham, D. M., Lubomski, L. H., Hyzy, R. C., Welsh, R., et al. (2011) Collaborative cohort study of an intervention to reduce ventilator-associated pneumonia in the intensive care unit. Infection Control and Hospital Epidemiology, 32(4), 305–314.
  • Bingham, M., Ashley, J., De Jong, M., and Swift, C. (2010) Implementing a unit-level intervention to reduce the probability of ventilator-associated pneumonia. Nursing Research, 59(1 Suppl), S40–S47.
  • Bion, J. F., Abrusci, T., and Hibbert, P. (2010) Human factors in the management of the critically ill patient. British Journal of Anaesthesia, 105(1), 26–33.
  • Bird, D., Zambuto, A., O'Donnell, C., Silva, J., Korn, C., Burke, R., et al. (2010) Adherence to ventilator-associated pneumonia bundle and incidence of ventilator-associated pneumonia in the surgical intensive care unit. Archives of Surgery, 145(5), 465–470.
  • Bloos, F., Müller, S., Harz, A., Gugel, M., Geil, D., Egerland, K., et al. (2009) Effects of staff training on the care of mechanically ventilated patients: A prospective cohort study. British Journal of Anaesthesia, 103(2), 232–237.
  • Blot, S. I., Serra, M. L., Koulenti, D., Lisboa, T., Deja, M., Myrianthefs, P., et al. (2011) Patient to nurse ratio and risk of ventilator-associated pneumonia in critically ill patients. American Journal of Critical Care, 20(1), e1–e9.
  • Bouadma, L., Mourvillier, B., Deiler, V., Le Corre, B., Lolom, I., Régnier, B., et al. (2010) A multifaceted program to prevent ventilator-associated pneumonia: Impact on compliance with preventive measures. Critical Care Medicine, 38(3), 789–796.
  • Cason, C. L., Tyner, T., Saunders, S., and Broome, L. (2007) Nurses' implementation of guidelines for ventilator-associated pneumonia from the Centers for Disease Control and Prevention. American Journal of Critical Care, 16(1), 28–37.
  • Chastre, J., and Fagon, J. Y. (2002) Ventilator-associated pneumonia. American Journal of Respiratory and Critical Care Medicine, 165(7), 867–903.
  • Drakulovic, M. B., Torres, A., Bauer, T. T., Nicolas, J. M., Nogué, S., and Ferrer, M. (1999) Supine body position as a risk factor for nosocomial pneumonia in mechanically ventilated patients: A randomised trial. The Lancet, 354(9193), 1851–1858.
  • Dubose, J., Teixeira, P.G.R., Inaba, K., Lam, L., Talving, P., Putty, B., Plurad, D., et al. (2010) Measurable outcomes of quality improvement using a daily quality rounds checklist: One-year analysis in a trauma intensive care unit with sustained ventilator-associated pneumonia reduction. Journal of Trauma and Acute Care Surgery, 69(4), 855–860.
  • Dudeck, M. A., Weiner, L. M., Allen-Bridson, K., et al. (2013) National Healthcare Safety Network (NHSN) report, data summary for 2012, “Device-Associated Module.” American Journal of Infection Control, 41(12), 1148–66.
  • Eagye, K. J., Nicolau, D. P., and Kuti, J. L. (2009) Impact of superinfection on hospital length of stay and costs in patients with ventilator-associated pneumonia. Seminars in Respiratory and Critical Care Medicine, 30(1), 116–123.
  • Efrati, S., Deutsch, I., Antonelli, M., Hockey, P. M., Rozenblum, R., and Gurman, G. M. (2010) Ventilator-associated pneumonia: Current status and future recommendations. Journal of Clinical Monitoring and Computing, 24(2), 161–168.
  • El-Khatib, M. F., Zeineldine, S., Ayoub, C., Husari, A., and Bou-Khalil, P. K. (2010) Critical care clinicians' knowledge of evidence-based guidelines for preventing ventilator-associated pneumonia. American Journal of Critical Care, 19(3), 272–276.
  • Fries, J., Hlady, C., Herman, T., Polgreen, P. M., and Segre, A. M. (2012) A low-cost non-RFID based method for automated monitoring of hand hygiene compliance. Program and Abstracts of the 19th Annual Scientific Meeting of the Society for Healthcare Epidemiology of America (SHEA), San Diego, CA. Abstract 123.
  • Fries, J., Segre, A. M., Thomas, G. W., Herman, T., Ellingson, K., and Polgreen, P. M. (2012) Monitoring hand hygiene via human observers: How should we be sampling? Infection Control and Hospital Epidemiology, 33(7), 689–695.
  • Grap, M. J., Munro, C. L., Hummel, R. S., Elswick, R. K., McKinney, J. L., and Sessler, C. N. (2005) Effect of backrest elevation on the development of ventilator-associated pneumonia. American Journal of Critical Care, 14(4), 325–332.
  • Grimshaw, J. M., Shirran, L., Thomas, R., Mowatt, G., Fraser, C., Bero, L., Grilli, R., Harvey, E., Oxman, A., and O'Brien, M. A. (2001) Changing provider behavior: An overview of systematic reviews of interventions. Medical Care, 39(8 Suppl 2), II2–II45.
  • Hawe, C. S., Ellis, K. S., Cairns, C. J., and Longmate, A. (2009) Reduction of ventilator-associated pneumonia: Active versus passive guideline implementation. Intensive Care Medicine, 35(7), 1180–1186.
  • Helman Jr., D. L., Sherner III, J. H., Fitzpatrick, T. M., Callender, M. E., and Shorr, A. F. (2003) Effect of standardized orders and provider education on head-of-bed positioning in mechanically ventilated patients. Critical Care Medicine, 31(9), 2285–2290.
  • Herman, T., Pemmaraju, S. V., Segre, A. M., Polgreen, P. M., Curtis, D. E., Fries, J., et al. (2009) Wireless applications for hospital epidemiology. Proceedings of the 1st ACM International Workshop on Medical-Grade Wireless Networks, New Orleans, LA, 45–50.
  • Hornbeck, T., Curtis, D. E., Herman, T., Thomas, G., Segre, A. M., and Polgreen, P. M. (2011) Contact patterns for HCWs: Not everyone is the “average.” 21st Annual Scientific Meeting of the Society for Healthcare Epidemiology of America, Dallas, TX. Abstract 423.
  • Hornbeck, T., Naylor, D., Segre, A. M., Thomas, G., Herman, T., and Polgreen, P. M. (2012) Using sensor networks to study the effect of peripatetic healthcare workers on the spread of hospital-associated infections. Journal of Infectious Diseases, 206(10), 1549–1557.
  • Hysong, S. J. (2009) Meta-analysis: Audit and feedback features impact effectiveness on care quality. Medical Care, 47(3), 356–363.
  • Hysong, S. J., Best, R. G., and Pugh, J. A. (2006) Audit and feedback and clinical practice guideline adherence: Making feedback actionable. Implementation Science, 1(1), 9.
  • Kaynar, A. M., Mathew, J. J., Hudlin, M. M., Gingras, D. J., Ritz, R. H., Jackson, M. R., et al. (2007) Attitudes of respiratory therapists and nurses about measures to prevent ventilator-associated pneumonia: A multicenter, cross-sectional survey study. Respiratory Care, 52(12), 1687–1694.
  • Kluger, A. N., and DeNisi, A. (1998) Feedback interventions: Toward the understanding of a double-edged sword. Current Directions in Psychological Science, 7(3), 67–72.
  • Labeau, S., Vandijck, D. M., Claes, B., Van Aken, P., Blot, S. I., and on behalf of the executive board of the Flemish Society for Critical Care Nurses. (2007) Critical care nurses' knowledge of evidence-based guidelines for preventing ventilator-associated pneumonia: An evaluation questionnaire. American Journal of Critical Care, 16(4), 371–377.
  • Laux, L., Dysert, K., Kiely, S., and Weimerskirch, J. (2010) Trauma VAP SWAT team: A rapid response to infection prevention. Critical Care Nursing Quarterly, 33(2), 126–131.
  • Lawrence, P., and Fulbrook, P. (2012) Effect of feedback on ventilator care bundle compliance: Before and after study. Nursing in Critical Care, 17(6), 293–301.
  • Leape, L. L. (1994) Error in medicine. JAMA: The Journal of the American Medical Association, 272(23), 1851–1857.
  • Leape, L. L., and Berwick, D. M. (2005) Five years after to err is human. JAMA: The Journal of the American Medical Association, 293(19), 2384–2390.
  • Magill, S. S., Edwards, J. R., Bamberg, W., et al. (2014) Multistate point-prevalence survey of health care-associated infections. New England Journal of Medicine, 370(13), 1198–208.
  • Markewitz, B. A., Mayer, J., Westenskow, D., and Richardson, S. (2005) Use of an inclinometer-data logger tool for continuous recording of head of bed position in patients undergoing mechanical ventilation. CHEST Journal, 128(4_MeetingAbstracts), 303S–b.
  • Marra, A. R., Cal, R.G.R., Silva, C. V., Caserta, R. A., Paes, Â.T., Moura Jr., D. F., et al. (2009) Successful prevention of ventilator-associated pneumonia in an intensive care setting. American Journal of Infection Control, 37(8), 619–625.
  • Moteiv Corporation. (2004) Telos Rev B (Low Power Wireless Sensor Module) Preliminary Datasheet. http://www2.ece.ohio-state.edu/∼bibyk/ee582/telosMote.pdf.
  • Muscedere, J. G., Martin, C. M., and Heyland, D. K. (2008) The impact of ventilator-associated pneumonia on the Canadian health care system. Journal of Critical Care, 23(1), 5–10.
  • Peterlini, M.A.S., Rocha, P. K., Kusahara, D. M., and Pedreira, M. L. (2006) Subjective assessment of backrest elevation: Magnitude of error. Heart & Lung: The Journal of Acute and Critical Care, 35(6), 391–396.
  • Polgreen, P. M., Hlady, C. S., Severson, M. A., Segre, A. M., and Herman, T. (2010) Method for automated monitoring of hand hygiene adherence without radio-frequency identification. Infection Control and Hospital Epidemiology: The Official Journal of the Society of Hospital Epidemiologists of America, 31(12), 1294.
  • Reason, J. (2000) Human error: Models and management. British Medical Journal, 320(7237), 768–770.
  • Reason, J. (2005) Safety in the operating theatre: Part 2: Human error and organisational failure. Quality & Safety in Health Care, 14(1), 56–60.
  • Reid, P. P., Compton, W. D., Grossman, J. H., and Fanjiang, G. (Eds.). (2005) Building a Better Delivery System: A New Engineering/Health Care Partnership. National Academies Press, Washington, DC.
  • Rose, L., Baldwin, I., and Crawford, T. (2010) The use of bed-dials to maintain recumbent positioning for critically ill mechanically ventilated patients (The RECUMBENT study): Multicentre before and after observational study. International Journal of Nursing Studies, 47(11), 1425–1431.
  • Rotstein, C., Evans, G., Born, A., Grossman, R., Light, R. B., Magder, S., et al. (2008) Clinical practice guidelines for hospital-acquired pneumonia and ventilator-associated pneumonia in adults. The Canadian Journal of Infectious Diseases & Medical Microbiology, 19(1), 19–53.
  • Scott, R. D. (2009) The direct medical costs of healthcare-associated infections in US hospitals and the benefits of prevention. National Center for Preparedness, Detection, and Control of Infectious Diseases (U.S.), Division of Healthcare Quality Promotion, 1–16.
  • Sexton, J. B., Thomas, E. J., and Helmreich, R. L. (2000) Error, stress, and teamwork in medicine and aviation: Cross-sectional surveys. British Medical Journal, 320(7237), 745–749.
  • Tablan, O. C., Anderson, L. J., Arden, N. H., Breiman, R. F., Butler, J. C., and McNeil, M. M. (1994) Guideline for prevention of nosocomial pneumonia. Infection Control and Hospital Epidemiology, 15(9), 587–627.
  • Tablan, O. C., Anderson, L. J., Besser, R., Bridges, C., and Hajjeh, R. (2003) CDC: Healthcare Infection Control Practices Advisory Committee: Guidelines for preventing health-care-associated pneumonia, 2003: Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee. MMWR Recomm Rep, 53(RR-3), 1–36.
  • Thomas, G. W., Pennathur, P., Falk, D. M., Myers, J., Ayres, B., and Polgreen, P. M. (2015) How lapse and slip errors influence head-of-bed angle compliance rates as measured by a portable, wireless data collection system. IIE Transactions on Healthcare Systems Engineering, 5(1), 1–13.
  • US Department of Health and Human Services. (2012) Healthcare-associated infection (HAI). http://www.hhs.gov/ash/initiatives/hai/index.html.
  • Valdez, R. S., Ramly, E., and Brennan, P. F. (2010) Final Report: Industrial and Systems Engineering and Health Care: Critical Areas of Research. AHRQ Publication 10-0079. Agency for Healthcare Research and Quality, Rockville, MD.
  • van Nieuwenhoven, C. A., Vandenbroucke-Grauls, C., van Tiel, F. H., Joore, H. C., van Schijndel, R.J.S., van der Tweel, I., et al. (2006) Feasibility and effects of the semirecumbent position to prevent ventilator-associated pneumonia: A randomized study. Critical Care Medicine, 34(2), 396–402.
  • Williams, Z., Chan, R., and Kelly, E. (2008) A simple device to increase rates of compliance in maintaining 30-degree head-of-bed elevation in ventilated patients. Critical Care Medicine, 36(4), 1155–1157.
  • Wolken, R. F., Woodruff, R. J., Smith, J., Albert, R. K., and Douglas, I. S. (2012) Observational study of head of bed elevation adherence using a continuous monitoring system in a medical intensive care unit. Respiratory Care, 57(4), 537–543.
  • Zapf, D., and Reason, J. T. (1994) Introduction: Human errors and error handling. Applied Psychology, 43(4), 427–432.
  • Zaydfudim, V., Dossett, L. A., Starmer, J. M., Arbogast, P. G., Feurer, I. D., Ray, W. A., et al. (2009) Implementation of a real-time compliance dashboard to help reduce SICU ventilator-associated pneumonia with the ventilator bundle. Archives of Surgery, 144(7), 656–662.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.