Deferring angioplasty in intermediate coronary lesions based on coronary flow criteria is safe: comparison of a deferred group to an intervention group

, , , , &
Pages 35-40 | Published online: 10 Jul 2009

  • Grondin CM, Dyrda I, Pasternac A, Campean L, Bourassa MG, Lesperance J. Discrepancies between cineangiographic and postmortem studies. Circulation 1974; 49: 703-708.
  • Zir LM, Miller SW, Dinsomore RE, Gilbert JP, Harthorne JW. Interobserver variability in coronary angiography. Circulation 1978; 53: 627-632.
  • Arnett EN, Isner JM, Redwood DR, et al. Coronary heart disease. Comparison of cineangiographic and necropsy findings. Ann Intern Med 1979; 91: 350-356.
  • Klocke FJ. Measurements of coronary blood flow and degree of stenosis: Current clinical implications and continuing uncertainties. J Am Coll Cardiol 1983; 1: 31-41.
  • Bertrand ME, Lablanche JM, Bauters C, Leroy F, MacFadden E. Discordant results of visual and quantitative estimates of stenosis severity before and after coronary angioplasty. Cathet Cardiovasc Diagn 1993; 28: 1-6.
  • American College of Physicians. Efficacy of exercise thallium-201 scintigraphy in the diagnosis and prognosis of coronary artery disease. Ann Inter Med 1990; 113: 703-704.
  • Bodenheimer MM, Banka VS, Helfant RH. Nuclear Cardiology II. The role of myocardial perfusion imaging using thallium-201 in diagnosis of coronary artery disease. Am J Cardiol 1980; 45: 674-684.
  • Roger VL, Pellika PA, Oh JK, Miller FA, Seward JB, Tajik AJ. Stress echocardiography. Part I. Exercise echocardiography: techniques, implementation, clinical applications and correlations. Mayo Clin Proc 1995; 70: 5-15.
  • Topol EJ, Ellis SG, Cosgrove DM, et al. Analysis of coronary angioplasty practice in the United States with an insurance-claims database. Circulation 1993; 87: 1489-1497.
  • Ofili EO, Kern MJ, Labovitz AJ, et al. Analysis of coronary blood flow velocity dynamics in angiographically normal and stenosed arteries before and after endolumen enlargement by angioplasty. J Am Coll Cardiol 1993; 21: 308-316.
  • Doucette JW, Corl PD, Payne HM, et al. Validation of a Doppler guidewire for intravascular measurement of coronary artery flow velocity. Circulation 1992; 85: 1899-1911.
  • Baim DS, Grossman W. Coronary angiography. In: Baim DS, Grossman W, eds. Cardiac Cathteterization, Angiography and Intervention. 5th Edn. Baltimore, Maryland: Williams & Wilkins, 1996: 183-218.
  • Uren NG, Melin JA, De Bruyne B, Wijns W, Baudhuin T, Camici PG. Relation between myocardial blood flow and the severity of coronary artery stenosis. N Engl J Med 1994; 330: 1782-1788.
  • Roguin A, Beyar R. The acute effect of stenting with the nitinol self-expanding coil stent: Preliminary experience. Int J Cardiac Imaging 1997; 13: 441-450.
  • Wilson RF, Wyche K, Christensen BV, Laxson DD. Effects of adenosine on human coronary artery circulation. Circulation 1990; 82: 1595-1606.
  • Wilson RF, Johnson MR, Marcus ML, et al. The effect of coronary angioplasty on coronary flow reserve. Circulation 1988; 77: 873-885.
  • Kern MJ, Deligonul U, Vandermael M, et al. Impaired coronary vasodilatatory reserve in the immediate post-coronary angioplasty period: analysis of coronary arterial velocity flow indices and regional cardiac venous efflux. J Am Coll Cardiol 1989; 3: 860-872.
  • Baim DS. Coronary angioplasty. In: Baim DS, Grossman W, eds. Cardiac Cathteterization, Angiography and Intervention. 5th Edn. Baltimore, Maryland: Williams & Wilkins, 1996: 537-579.
  • Donahue TJ, Kern MJ, Aguirre FV, et al. Assessing the hemodynamic significance of coronary artery stenoses: analysis of translesional pressure-flow velocity relationship in patients. J Am Coll Cardiol 1993; 22: 449-458.
  • Offili EO, Labovitz AJ, Kern MJ. Coronary flow velocity dynamics in normal and diseased arteries. Am J Cardiol 1993; 71: 3D-9D.
  • Bach RG, Donahue TJ, Kern MJ. Intracoronary Doppler flow velocity measurements for the evaluation and treatment of coronary artery disease. Curr Opin Cardiol 1995; 10: 434-442.
  • Miller DD, Donohue TJ, Younis LT, et al. Correlation of pharmacological 99mTc-sestamibi myocardial perfusion imaging with poststenotic coronary flow reserve in patients with angiographically intermediate coronary stenoses. Circulation 1994; 89: 2150-2160.
  • Kern MJ, Donohue TJ, Aguirre FV, et al. Clinical outcome of deferring angioplasty in patients with normal translesional pressure-flow velocity measurements. J Am Coll Cardiol 1995; 25: 178-187.
  • Laarman GJ, Serruys PW, Suryapranata H, et al. Inability of coronary blood flow reserve measurements to assess the efficacy of coronary angioplasty in the first 24 hours in unselected patients. Am Heart J 1991; 122: 631-639.
  • Stiel GM, Lund GK, Schaps KP, Latterman A, Nienaber CA. Visual assessment or quantitative measurement of coronary stenoses: significance of for 'prima vista-PTCA'. Z Kardiol 1997; 86: 189-195.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.