References
- Bessoud B, de Baere T, Kuoch V et al. Experience at a single institution with endovascular treatment of mechanical compli-cations caused by implanted central venous access devices in pediatric and adult patients. AJR 2003; 180: 527–32.
- Bjarnason H, Lehmann S. Central venous access. In: Castalleda-Zuiliga W, ed. Interventional radiology, 3rd edn, Vol. 1. Baltimore: Williams & Wilkins, 1997: 941.
- Brady PS, Spence LD, Levitin A, Mickolich CT, Dolmatch BL. Efficacy of percutaneous fibrin sheath stripping in restoring patency of tunneled hemodialysis catheters. AJR 1999; 173: 1023–7.
- Crain MR, Horton MG, Mewissen MW. Fibrin sheaths complicating central venous catheters. AJR 1998; 171: 341–6.
- Crain MR, Mewissen MW, Ostrowski GJ, Paz-Fumagalli R, Beres RA, Wertz RA. Fibrin sleeve stripping for salvage of failing hemodialysis catheters: Technique and initial results. Radiology 1996; 198: 41–4.
- Harker C, Richardson M, Althaus S, Coldwell D. Malfunction of Hickman catheters: Effect of catheter position. http:Ilej.rsna.orglej210066-97.finlabstract.html (30.05.01).
- Hoshal VL, Ause RG, Hoskins PA. Fibrin sleeve formation on indwelling subclavian central venous catheters. Arch. Surg. 1971; 102: 353–8.
- Motin J, Fischer G, Evreux J. Interet de la voie sous-claviculaire en reanimation prolongee. Lyon Med. 1964; 212: 583–93.
- Namyslowski J, Patel N. Central venous access: a new task for interventional radiologists. Cardiovasc. Intervent. Radiol. 1999; 22: 355–68.
- Nolsoe C, Nielsen L, Karstrup S, Lauritsen K. Ultrason-ically guided subclavian vein catherization. Acta Radiol. 1989; 30: 108–9.
- Punt CJ, Strijk S, van der Hoeven JJ, van de Sluis R, Verhagen CA. Spontaneous fracture of implanted central venous catheters in cancer patients: report of two cases and retrospective analysis of the "pinch-off sign" as a risk fac-tor. Anticancer Drugs 1995; 6: 594–8.
- Trerotola SO. Hemodialysis catheter placement and man-agement. Radiology 2000; 215: 651–8.
- Trerotola SO, Kuhn-Fulton J, Johnson MS, Shah H, Ambrosius WT, Kneebone PH. Tunneled infusion cath-eters. Increased incidence of symptomatic venous thrombosis after subclavian versus internal jugular venous access. Radi-ology 2000; 217: 89–93.
- Whitman ED. Complications associated with the use of central venous access devices. Curr. Probl. Surg. 1996; 23: 309–88.
- Yedlicka JW, Qian Z, Castalieda-Zuffiga W. Intravascular foreign body removal. In: Castalleda-Zufiiga W, ed. Inter-ventional radiology, 3rd edn, Vol. 1. Baltimore: Williams & Wilkins, 1997.
- Yip D, Funaki B. Subcutaneous chest ports via the internal jugular vein. A retrospective study of 117 oncology patients. Acta Radiol. 2002; 43: 371–5.