53
Views
13
CrossRef citations to date
0
Altmetric
BIOANALYTICAL

A Multicommuted Flow Procedure for the Determination of Cholesterol in Animal Blood Serum by Chemiluminescence

, , &
Pages 3011-3024 | Received 05 Aug 2003, Accepted 11 Aug 2003, Published online: 02 Feb 2007

References

  • Braco , L. , Dabulis , K. and Klibanov , A.M. 1990 . Production of abiotic receptors by molecular imprinting . P. Natl. Acad. Sci. USA , 87 ( 1 ) : 274 – 277 .
  • Coles , E.H. 1980 . Veterinary Clinical Pathology, , 3a Ed. 31 – 33 . Philadelphia : W. B. Saunders .
  • Krug , A. , Gobel , R. and Kellner , R. 1994 . Flow-injection analysis for total cholesterol with photometric detection . Anal. Chim. Acta , 287 : 59 – 64 .
  • Araújo , A.N. , Catita , J.A.M. and Lima , J.L.F.C. 1999 . Monosegmented flow-analysis of serum cholesterol . IL Farmaco , 54 : 51 – 55 .
  • Situmorang , M. , Alexander , P.W. and Hibbert , D.B. 1999 . Flow injection potentiometry for enzymatic assay of cholesterol with a tungsten electrode sensor . Talanta , 49 : 639 – 649 .
  • Malik , V. and Pundir , C.S. 2002 . Determination of total cholesterol in serum by cholesterol esterase and cholesterol oxidase immobilized and co-immobilized on to arylamine glass . Biotechnol. Appl. Biochem. , 35 : 191 – 197 .
  • Yao , T. , Sato , M. , Kobayashi , Y. and Wasa , T. 1985 . Amperometric assays of total and free cholesterols in serum by the combined use of immobilized cholesterol esterase and cholesterol oxidase reactors and peroxidase electrode in a flow injection system . Anal. Biochem. , 149 : 387 – 391 .
  • Masoom , M. and Townshend , A. 1985 . Determination of cholesterol by flow injection analysis with immobilized cholesterol oxidase . Anal. Chim. Acta , 174 : 293 – 297 .
  • Yao , T. , Satomura , M. and Nakahara , T. 1994 . Amperometric flow-injection determination of glucose, urate and cholesterol in blood serum by using some immobilized enzyme reactors and a poly(1,2-diaminobenzene)-coated platinum electrode . Anal. Chim. Acta , 296 : 271 – 276 .
  • Tabata , M. , Endo , J. and Murachi , T. 1981 . Automated analysis of total cholesterol in serum using coimmobilized cholesterol ester hydrolase and cholesterol oxidase . J. Appl. Biochem. , 3 : 84 – 92 .
  • Blum , L.J. , Plaza , J.M. and Coulet , P.R. 1987 . Chemiluminescent analyte microdetection based on the luminol-H2O2 reaction using peroxidase immobilized on new synthetic membranes . Anal. Lett. , 20 ( 2 ) : 317 – 326 .
  • Sasamoto , H. , Maeda , M. and Tsuji , A. 1995 . Chemiluminescent enzymatic assay for cholesterol in serum using lucigenin . Anal. Chim. Acta , 310 : 347 – 353 .
  • Li , J.Z. and Dasgupta , P.K. 1999 . Chemiluminescence detection with a liquid core waveguide—determination of ammonium with electrogenerated hypochlorite based on the luminol-hypochlorite reaction . Anal. Chim. Acta , 398 ( 1 ) : 33 – 39 .
  • Martelli , P.B. , Reis , B.F. , Araújo , A.N. and Montenegro , M.C.B.S.M.A. 2001 . Flow system with a conventional spectrophotometer for the chemiluminecent determination of lactic acid in yoghurt . Talanta , 54 : 879 – 885 .
  • Nabi , A. , Rashid , A. and Yaqoob , M. 1996 . Chemiluminescent determination of cholesterol by flow injection analysis with immobilized cholesterol oxidase . Anal. Lett. , 29 ( 13 ) : 2281 – 2288 .
  • Huang , Y. , Zhang , C. and Zhang , Z. 1999 . Chemiluminescence flow biosensor system for cholesterol with immobilized reagents . Anal. Sci. , 15 : 867 – 870 .
  • Garrido , J.M.P.J. , Delerue-Matos , C. , Borges , F. , Macedo , T.R.A. and Oliveira-Brett , A.M. 2002 . Electroanalytical determination of codeine in pharmaceutical preparations . Anal. Lett. , 35 ( 15 ) : 2487 – 2498 .
  • Perez-Ruiz , T. , Martinez-Lozano , C. , Tomas , V. and Fenoll , J. 2003 . Spectrofluorimetric determination of formaldehyde by a flow-injection method based on its catalytic effect on the acridine yellow-bromate reaction . Anal. Bioanal. Chem. , 375 ( 5 ) : 661 – 665 .
  • Silva , H.R. , Segundo , M.A. and Rangel , A.O.S.S. 2003 . Use of a mixing chamber for sample preparation and multiple collection in sequential injection analysis: determination of sulfate in wines . J. Braz. Chem. Soc. , 14 ( 1 ) : 59 – 64 .
  • Pimenta , A.M. , Araujo , A.N. and Montenegro , M.C.B.S.M.A. 2002 . A sequential injection analysis system for potassium clavulanate determination using two potentiometric detectors . J. Pharmaceut. Biomed. , 30 ( 4 ) : 931 – 937 .
  • Vieira , J.A. , Raimundo , I.M. , Reis , B.F. , Montenegro , M.C.B.S.M. and Araujo , N.N. 2003 . Monosegemented flow potentiometric titration for the determination of chloride in milk and wine . J. Braz. Chem. Soc. , 14 ( 2 ) : 259 – 264 .
  • Rocha , F.R.P. , Reis , B.F. , Zagatto , E.A.G. , Lima , J.L.F.C. , Lapa , R.A.S. and Santos , J.L.M. 2002 . Multicommutation in flow analysis: concepts, applications and trends . Anal. Chim. Acta , 468 ( 1 ) : 119 – 131 .
  • Zagatto , E.A.G. , Rocha , F.R.P. , Martelli , P.B. and Reis , B.F. 2001 . Detecting and circumventing sources of inaccuracy in flow analysis . Pure Appl. Chem. , 73 ( 1 ) : 45 – 54 .
  • 1999 . “ LABTEST Diagnóstica. Colesterol Liquiform ” . cat. 76–2/100 Mg-BR .
  • Matsumoto , K. , Kamikado , H. , Matsubara , H. and Osajima , Y. 1988 . Simultaneous determination of glucose, fructose, and sucrose in mixtures by amperometric flow injection analysis with immobilized enzyme reactors . Anal. Chem. , 60 ( 2 ) : 147 – 151 .
  • Borges , E.P. , Fernandes , E.N. , Rocha , F.R.P. and Reis , B.F. 2002 . Development of a low cost device for chemiluminescence measurements . Quim. Nova , 25 ( 6B ) : 1191 – 1193 .
  • Christian , G.D. 1986 . “ Clinical chemistry ” . In Analytical Chemistry, , 4th Ed. 521 – 523 . New York : John Wiley & Sons .
  • 1993 . Joint FAO/IAEA Programme Animal Production and Health: Nutricional Metabolite Kit Protocols 1 – 12 . Seibersdorf : Agency's Laboratories .
  • Blunt , M.H. 1977 . “ The blood of sheep ” . In Composition and Function 55 – 57 . New York : Springer-Verlag .
  • 1987 . IUPAC Analytical Methods Committee. Recommendations for the definition, estimation and use of the detection limit . Analyst , 112 ( 2 ) : 199 – 204 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.