References
- Aboul‐Enein , H. Y. and Abou‐Basha , L. I. 1997 . “ Chirality and drug hazards ” . In The Impact of Stereochemistry on Drug Development and Use Edited by: Aboul‐Enein , H. Y. and Wainer , I. W. 1 – 19 . New York : John Wileys Sons, Inc. . Chap. I
- Egginger , G. , Lindner , W. , Vandenbosch , C. and Massart , D. L. 1993 . Enantioselective bioanalysis of beta‐blocking agents: focus on atenolol, betaxolol, carvedilol, metoprolol, pindolol, propranolol and sotalol . Biomed. Chromatogr. , 7 : 278 – 295 . (and references cited therein)
- Caldwell , J. 1996 . Importance of stereospecific bioanalytical monitoring in drug development . J. Chromatogr. A , 719 : 3 – 13 .
- Dyas , A. M. 1992 . The chiral chromatographic separation of β‐adrenoceptor blocking drugs . J. Pharm. Biomed. Anal. , 10 : 383 – 404 .
- Stefan , R. I. , van Staden , J. F. and Aboul‐Enein , H. Y. 2001 . “ Enantioselective electrochemical sensors ” . In Electrochemical Sensors in Bioanalysis 179 – 197 . New York : Marcel Dekker Inc. . Chap. 9, In
- Stefan , R. I. , Aboul‐Enein , H. Y. and van Staden , J. F. 2002 . “ Enantioselective electrochemical sensors ” . In Sensors Update Edited by: Baltes , H. , Fedder , G. K. and Korvink , J. G. Vol. 10 , 123 – 141 . Weinheim, , Germany : Wiley‐VCH . Chap. 2.1
- Horvath , V. , Takacs , T. , Horvai , G. , Huszthy , P. , Bradshaw , J. S. and Izatt , R. M. 1997 . Enantiomer‐selectivity of ion‐selective electrodes based on a chiral crown‐ether ionophore . Anal. Lett. , 30 ( 9 ) : 1591 – 1609 .
- Kataky , R. , Bates , P. S. and Parker , D. 1992 . Functionalized α‐cyclodextrins as potentiometric chiral sensors . Analyst , 117 : 1313 – 1317 .
- Bates , P. S. , Kataky , R. and Parker , D. 1994 . Functionalized cyclodextrins as potentiometric chiral sensors . Analyst , 119 : 181 – 186 .
- Bates , P. S. , Kataky , R. and Parker , D. 1994 . Chiral sensors based on lipophilic cyclodextrins: interrogation of enantioselectivity by combined NMR, structural correlation and electrode response studies . J. Chem. Soc. Perkin Trans. 2 , : 669 – 675 .
- Kataky , R. , Parker , D. and Kelly , P. M. 1995 . Potentiometric, enantioselective sensors for alkyl and aryl ammonium ions of pharmaceutical significance, based on lipophilic cyclodextrin . Scand. J. Clin. Lab. Invest. , 55 : 409 – 419 .
- Parker , D. and Kataky , R. 1997 . Selective complexation and sensitive analysis of charge diffuse cationic species using lipophilic cyclodextrins . Chem. Commun. , : 141 – 145 .
- Sun , X. X. and Ding , H. L. 1999 . Ion‐selective electrode for the determination of the beta‐adrenergic drug clenbuterol . Fenxi Shiyanshi , 18 : 75 – 79 .
- Qin , W. , Zwickl , T. and Pretsch , E. 2000 . Improved detection limits and unbiased selectivity coefficients obtained by using ion‐exchange resins in the inner reference solution of ion‐selective polymeric membrane electrode . AC , 72 : 3236 – 3240 .
- Morf , W. E. , Badertscher , M. , Zwickl , T. , de Rooij , N. F. and Pretsch , E. 1999 . Effects of ion transport on the potential response of ionophore‐based membrane electrodes: a theoretical approach . J. Phys. Chem. B , 103 : 11346 – 11356 .
- Aboul‐Enein , H. Y. and Sun , X. X. 2000 . A novel ion selective PVC membrane electrode for determination of propranolol in pharmaceutical formulation . Analysis , 28 : 855 – 858 .