41
Views
5
CrossRef citations to date
0
Altmetric
Chemical and Biosensors

Lead Ion‐Selective Membrane Electrode Based on a Novel Fluorene Derivative

, , , &
Pages 3149-3159 | Received 20 Jul 2004, Accepted 18 Aug 2004, Published online: 22 Aug 2007

References

  • Buhlmann , P. , Pretsch , E. and Bakker , E. 1998 . Carrier‐based ion‐selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors . Chem. Rev. , 98 ( 4 ) : 1593 – 1687 .
  • Lindner , E. , Tóth , K. , Pungor , E. , Behm , F. , Oggenfuss , P. , Welti , D. H. , Ammann , D. , Morf , W. E. , Pretsch , E. and Simon , W. 1984 . Lead‐selective neutral carrier based liquid membrane electrode . Anal. Chem. , 56 ( 7 ) : 1127 – 1131 .
  • Bakker , E. , Willer , M. and Pretsch , E. 1993 . Detection limit of ion‐selective bulk optodes and corresponding electrodes . Anal. Chim. Acta , 282 ( 2 ) : 265 – 271 .
  • Kim , J. S. , Ohki , A. , Cho , N. S. , Yu , I. Y. , Hayashita , T. and Maeda , S. 1996 . Novel acyclic polyethers bearing amide end groups and their complexation studies . Bull. Korean Chem. Soc. , 17 ( 10 ) : 953 – 955 .
  • Didina , S. E. , Mitnik , L. L. , Koshmina , N. N. , Grekovich , A. L. and Mikhelson , K. N. 1994 . Lead‐selective electrodes based on liquid ion‐exchanges . Sensors Actuators, B , 19 ( 1–3 ) : 396 – 399 .
  • Malinowska , E. 1990 . Lead‐selective membrane electrodes based on neutral carriers Part 1. Acyclic amides and oxamides . Analyst , 115 ( 8 ) : 1085 – 1087 .
  • Kamata , S. and Onoyama , K. 1991 . Lead‐selective membrane electrode using methylene bis(diisobutyldithiocarbamate) neutral carrier . Anal. Chem. , 63 ( 13 ) : 1295 – 1298 .
  • Xu , D. and Katsu , T. 2000 . Tetrabenzyl pyrophosphate as a new class of neutral carrier responsive to lead ion . Talanta , 51 ( 2 ) : 365 – 371 .
  • Sheen , S. R. and Shih , J. S. 1992 . Lead(II) ion‐selective electrodes based on crown ethers . Analyst , 117 ( 11 ) : 1691 – 1695 .
  • Srivastava , S. K. , Gupta , V. K. and Jain , S. 1995 . Determination of lead using a poly(vinylchloride)‐based crown ether membrane . Analyst , 120 ( 2 ) : 495 – 498 .
  • Tavakkoli , N. and Shamsipur , M. 1996 . Lead‐selective membrane electrode based on dibenzopyrydino‐18‐crown‐6 . Anal. Lett. , 29 ( 13 ) : 2269 – 2279 .
  • Malinowska , E. , Brzózka , Z. , Kasiura , K. , Egberink , R. and Reinhoudt , D. 1994 . Lead selective electrodes based on thioamide functionalized calix[4]arenes as ionophores . Anal. Chim. Acta , 298 ( 2 ) : 253 – 258 .
  • Tavakkoli , N. , Khojasteh , Z. , Sharghi , H. and Shamsipur , M. 1998 . Lead ion‐selective membrane electrodes based on some recently synthesized 9,10‐anthraquinone derivatives . Anal. Chim. Acta , 360 ( 1–3 ) : 203 – 208 .
  • 1976 . Commission on analytical nomenclature. Recommendations for nomenclature of ion selective electrodes . Pure Appl. Chem. , 48 ( 1 ) : 127 – 132 . IUPAC Analytical Chemistry Division
  • Pungor , E. and Toth , K. 1969 . Selectivity of ion‐specific membrane electrodes . Anal. Chim. Acta , 47 ( 2 ) : 291 – 297 .
  • Bakker , E. , Buhlmann , P. and Pretsch , E. 1997 . Carrier‐based ion‐selective electrodes and bulk optodes. 1. General characteristics . Chem. Rev. , 97 ( 8 ) : 3083 – 3132 .
  • Ammann , D. , Morf , W. E. , Anker , P. , Meier , P. C. , Pretsch , E. and Simon , W. 1983 . Neutral carrier based ion‐selective electrodes . Ion‐selective Electrode Rev. , 5 ( 1 ) : 3 – 92 .
  • Lindner , E. , Gráf , E. , Niegreisz , Z. , Tóth , K. , Pungor , E. and Buck , R. P. 1988 . Response of site‐controlled, plasticized membrane electrodes . Anal. Chem. , 60 ( 4 ) : 295 – 301 .
  • Rosatzin , T. , Bakker , E. , Suzuki , K. and Simon , W. 1993 . Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation‐selective chemical sensors . Anal. Chim. Acta , 280 ( 2 ) : 197 – 208 .
  • Mascini , M. and Liberty , A. 1972 . Preparation and analytical evaluation of a new lead (II) heterogeneous membrane electrode . Anal. Chim. Acta , 60 ( 2 ) : 405 – 412 .
  • Midgley , D. 1984 . Lead‐selective electrodes based on lead(IV) oxide . Anal. Chim. Acta , 159 : 63 – 70 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.