105
Views
15
CrossRef citations to date
0
Altmetric
Chemical and Biosensors

Chemiluminescence Microflow Injection Analysis System on a Chip for the Determination of Sulfite in Food

, &
Pages 563-571 | Received 13 Sep 2004, Accepted 14 Nov 2004, Published online: 02 Feb 2007

References

  • Fang , Q. , Wang , F. R. , Wang , S. L. , Liu , S. S. , Xu , S. K. and Fang , Z. L. 1999 . Sequential injection sample introduction microfluidic‐chip based capillary electrophoresis system . Anal. Chim. Acta , 390 : 27 – 37 .
  • Gorbounov , V. , Kuban , P. , Dasgupt , P. K. and Temkin , H. 2003 . A nanoinjector for microanalysis . Anal. Chem. , 75 : 3919 – 3923 .
  • Greenway , G. M. , Nelstrop , L. J. and Port , S. N. 2000 . Tris (2,2‐bipyridyl) ruthenium (II) chemiluminescence in a microflow injection system for codeine determination . Anal. Chim. Acta. , 405 : 43 – 50 .
  • Greenwood , P. A. , Merrin , C. , McCreedy , T. and Greenway , G. M. 2002 . Chemiluminescence µTAS for the determination of atropine and pethidine . Talanta , 56 : 539 – 545 .
  • Harrison , D. J. , Fang , Z. , Seiler , K. , Manz , A. and Widmer , H. M. 1993 . Rapid separation of fluorescein derivatives using a micromachined capillary eletrophoresis system . Anal. Chim. Acta , 283 : 361 – 366 .
  • Huang , Y. L. , Kim , J. M. and Schmid , R. D. 1992 . Determination of sulphite in wine through flow‐injection analysis based on the suppression of luminol chemiluminescence . Anal. Chim. Acta , 266 : 317 – 323 .
  • Huang , Y. M. , Zhang , C. , Zhang , X. R. and Zhang , Z. J. 1999 . Chemiluminescence of sulfite based on auto‐oxidation sensitized by rhodamine 6G . Anal. Chim. Acta , 391 : 95 – 100 .
  • Jacobson , S. C. , Moore , A. W. and Ramsey , J. M. 1995 . Fused quartz substrates for microchip electrophoresis . Anal. Chem. , 67 : 2059 – 2063 .
  • Kamidate , T. , Kaide , T. , Tani , H. , Makino , E. and Shibata , T. 2001 . Effect of the geometry of microfabricated flow reactors on chemiluminescence detection of epinephrine with lucigenin . Luminescence , 16 : 337 – 342 .
  • Kuratli , M. and Pretsch , E. 1994 . Sulfur dioxide‐selective optodes . Anal. Chem. , 66 : 85 – 91 .
  • Lin , J. M. and Hobo , T. 1996 . Flow‐injection analysis with chemiluminescent detection of sulphite using Na2CO3–NaHCO3‐Cu2+ system . Anal. Chim. Acta. , 323 : 69 – 73 .
  • Lv , Y. , Zhang , Z. J. and Chen , F. N. 2002 . Chemiluminescence biosensor chip based on a microreactor using carrier air flow for determination of uric acid in human serum . Analyst , : 1176 – 1179 .
  • Lv , Y. , Zhang , Z. J. and Chen , F. N. 2003 . Chemiluminescence microfluidic system sensor on a chip for determination of glucose in human serum with immobilized reagents . Talanta , 59 : 571 – 576 .
  • Manz , A. , Graber , N. and Widmer , H. M. 1990 . Miniaturized total chemical analysis systems: A novel concept for chemical sensing . Sensors Actuators B , 1 : 244 – 248 .
  • Michel , P. E. , Fiaccabrino , G. C. , Rooij , N. F. and Koudelka‐Hep , M. 1999 . Integrated sensor for continuous flow electrochemiluminescent measurements of codeine with different ruthenium complexes . Anal. Chim. Acta , 392 : 95 – 103 .
  • Nelstrop , L. J. , Greenwood , P. A. and Greenway , G. M. 2001 . An investigation of electroosmotic flow and pressure pumped luminol chemiluminescence detection for cobalt analysis in a miniaturised total analytical system . Lab on a Chip , 1 : 138 – 142 .
  • Neufeld , T. , Cohen , E. , Rishpon , J. and Eshkenazi , I. 2000 . A micro flow injection electrochemical biosensor for organophosphorus pesticides . Biosens. Bioelectronics , 15 : 323 – 329 .
  • Oleschuk , R. D. , Shultz‐Lockyear , L. L. , Ning , Y. and Harrison , D. J. 2000 . Trapping of bead‐based reagents within microfluidic systems: On‐chip solid‐phase extraction and electrochromatography . Anal. Chem. , 72 : 585 – 590 .
  • Petsul , P. H. , Haswell , S. J. and Greenway , G. M. 2001 . The development of an on‐chip micro‐flow injection analysis of nitrate with a cadmium reductor . Anal. Chim. Acta , 428 : 155 – 161 .
  • Qin , W. , Zhang , Z. J. and Zhang , C. J. 1998 . Reagentless chemiluminescence flow sensor for sulfite . Anal. Chim. Acta , 361 : 201 – 203 .
  • Rainelli , A. , Stratz , R. , Schweizer , K. and Hauser , P. C. 2003 . Miniature flow‐injection analysis manifold created by micromilling . Talanta , 61 : 659 – 665 .
  • Raymaond , D. E. , Manz , A. and Widmer , H. M. 1994 . Continuous sample pretreatment using a free‐flow electrophoresis device integrated onto a silicon chip . Anal. Chem. , 66 : 2858 – 2865 .
  • Simon , P. K. and Dasgupta , P. K. 1993 . Wet effluent denuder coupled liquid/ion chromatography systems: annular and parallel plate denuders . Anal. Chem. , 65 : 1134 – 1139 .
  • West , P. W. and Gaeke , G. C. 1956 . Fixation of sulfur dioxide as disulfitomercurate (II) and subsequent colorimetric estimation . Anal. Chem. , 28 : 1816 – 1819 .
  • Xu , Y. , Bessoth , F. G. , Eijkel , J. C.T. and Manz , A. 2000 . On‐line monitoring of chromium (III) using a fast micromachined mixer/reactor and chemiluminescence detection . Analyst , 125 : 677 – 684 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.