50
Views
8
CrossRef citations to date
0
Altmetric
Chemical and Biosensors

Lead‐Selective Potentiometric Sensor Based on Macrocyclic Ionophore [Pyo2(16)Diene N6]

, &
Pages 589-600 | Accepted 22 Nov 2004, Published online: 02 Feb 2007

References

  • Arida , H. A. , El‐Reefy , S. A. and El‐Saied , A. M. 2003 . A new lead (II)‐selective PVC‐coated graphite rod electrode based on a Schiff base complex . Anal. Sci. , 19 : 687 – 690 .
  • Attiyat , A. S. , Christian , G. D. , Cason , C. V. and Bartsch , R. A. 1992 . Benzo‐18‐crown‐6 and its lariat ether derivatives as ionophores for potassium, strontium and lead ion‐selective electrodes . Electroanalysis , 4 ( 1 ) : 51 – 56 .
  • Bakker , E. , Pretsch , E. and Buhlmann , P. 2000 . Selectivity of potentiometric ion sensors . Anal. Chem. , 72 : 1127 – 1133 .
  • Buck , R. P. and Cosofret , V. V. 1993 . Recommended procedure for calibration of ion‐selective electrodes . Pure Appl. Chem. , 65 : 18 – 49 .
  • Buck , R. P. and Lindner , E. 1994 . Recommendation for nomenclature of ion‐selective electrodes . Pure Appl. Chem. , 66 : 2527 – 2536 .
  • 1977 . “ Lead ” . In Environmental Health Criteria Vol. 3 , Geneva : World Health Organization .
  • Fenton , R. R. , Lindoy , L. F. , Luckay , R. C. , Turville , F. R. and Wei , G. 2001 . New macrocyclic ligands. XII phosphonic and phosphinic acid pendant arm derivatives of mixed donor macrocycles: towards new selective reagents for lead (II) . Aust. J. Chem. , 54 ( 1 ) : 59 – 62 .
  • Ganjali , M. R. , Hosseini , M. , Basiripour , F. , Javanbakht , M. , Hashemi , O. R. , Rastegar , M. F. , Shamsipur , M. and Buchanen , G. W. 2002 . Novel coated‐graphite membrane sensor based on N, N′‐dimethylcyanodiaza‐18‐crown‐6 for the determination of ultra‐trace amounts of lead . Anal. Chim. Acta , 464 ( 2 ) : 181 – 186 .
  • Gupta , V. K. , Mangla , R. and Agarwal , S. 2002 . Pb(II)‐selective potentiometric sensor based on 4‐tert‐butylcalix[4]arene in PVC matrix . Electroanalysis , 14 : 1127 – 1132 .
  • Lee , H. K. , Song , K. , Seo , H. R. , Choi , Y. K. and Jeon , S. 2004 . Lead (II)‐selective electrodes based on tetrakis(2‐hydroxy‐1‐naphthyl)porphyrins: effect of atropisomers . Sens. Actuators B , 99 : 323 – 329 .
  • Lu , J. , Chen , R. and He , X. 2002 . A lead ion‐selective electrode based on a calixarene carboxyphenyl azo derivative . J. Electroanal. Chem. , 528 : 33 – 38 .
  • Malinowska , E. 1990 . Lead‐selective membrane electrodes based on neutral carriers. Part I. Acyclic amides and oxamides . Analyst , 115 ( 8 ) : 1085 – 1087 .
  • Malinowska , E. , Brzozka , Z. , Kasiura , K. , Egberink , R. J.M. and Reinhoudt , D. N. 1994 . Lead selective electrodes based on thioamide functionalized calix[4]arenes as ionophores . Anal. Chim. Acta. , 298 ( 2 ) : 253 – 258 .
  • Major , R. H. 1939 . Classic Descriptions of Disease , 2nd Ed. Springfield, Illinois : Charles C. Thomas .
  • Morf , W. E. 1981 . The Principles of Ion Selective Electrodes and Membrane Transport Amsterdam : Elsevier .
  • Meier , P. C. , Morf , W. E. , Laeubli , M. and Simon , W. 1984 . Evaluation of the optimum composition of neutral‐carrier membrane electrodes with incorporated cation‐exchanger sites . Anal. Chim. Acta. , 156 : 1 – 8 .
  • Novikov , E. A. , Shpigun , L. K. and Zolotov , A. Y. 1987 . Lead‐selective electrodes based on macrocyclic reagents . Zh. Anal. Khim. , 42 : 885 – 890 .
  • Panwar , A. , Baniwal , S. , Sharma , C. L. and Singh , A. K. 2000 . A polystyrene based membrane electrode for cadmium (II) Ions . Fresenius J. Anal. Chem. , 368 : 768 – 772 .
  • Sadeghi , S. , Dashti , G. R. and Shamsipur , M. 2002 . Lead‐selective poly(vinyl chloride) membrane electrode based on piroxicam as a neutral carrier . Sensors and Actuators B , 81 ( 2–3 ) : 223 – 228 .
  • Saez de Viteri , F. J. and Diamond , D. 1994 . Determination and application of ion‐selective electrode model parameters using flow injection and simplex optimization . Analyst , 199 ( 5 ) : 749 – 758 .
  • Shamsipur , M. , Ganjali , M. R. and Rouhollahi , A. 2001 . Lead‐selective membrane potentiometric sensor based on an 18‐membered thiacrown derivative . Anal. Sci. , 17 : 935 – 938 .
  • Shpigun , L. K. , Novikov , E. A. and Zolotov , A. Y. 1986 . Synthetic macrocyclic reagents as membrane‐active components of a lead‐selective electrode . Zh. Anal. Khim. , 41 : 617 – 621 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.