737
Views
13
CrossRef citations to date
0
Altmetric
Original

The Artificial Pancreas

, &
Pages 127-138 | Published online: 24 Aug 2009

References

  • ADICOL ((Advanced Insulin infusion using a Control Loop)) Project. 5th EC Framework Programme. IST—Information Society Technologies. 1999, Project No.: IST‐‐1999‐‐14207
  • Albisser A. M., Leibel B. S., Ewart T. G., Davidovac Z., Botz C. K., Zingg W., Schipper H., Gander R. Clinical control of diabetes by the artificial pancreas. Diabetes 1974; 23: 397–404
  • Arnold M. A. Non‐‐invasive glucose monitorino. Curr. Opin. Biotechnol. 1996; 7: 46–49
  • Asakawa N., Saito Y., Yamasaki Y., Kawamori R., Shichiri M. Validation of closed‐‐loop subcutaneous insulin infusion algorithm. Application of subcutaneous insulin absorption kinetics. Diabetes Res. 1987; 5: 193–198
  • Chang K. W., Alsenberg S., Soeldner J. S., Hiebert J. M. Validation and bioengineering aspects of an implantable glucose sensor. Trans. Am. Soc. Artif. Intern. Organs 1973; 19: 352–360
  • Chen G., Guan Z., Chen C.‐‐T., Fu L., Sundaresan V., Arnold F. A glucose sensing polymer. Nat. Biotechnol. 1997; 15: 354–357
  • Diabetes Control and Complications Trial Research Group. The effect of intensive treatment of diabetes on the development and progression of long‐‐term complications in insulin‐‐dependent diabetes mellitus. N. Engl. J. Med. 1993; 322: 977–986
  • Gark S. K., Potts R. O., Ackerman N. R., Fermi S. J., Tamada J. T., Chase H. P. Correlation of fingerstick blood glucose measurements with GlucoWatch Biographer glucose results in young subjects with type 1 diabetes. Diabetes Care 1999; 22(10)1708–1714
  • Hashigughi Y., Sakakida M., Nishida K., Uemura T., Kajiwara K., Shichiri M. Development of a miniaturized glucose monitoring system by combining a needle‐‐type glucose sensor with microdyalisis sampling method. Diabetes Care 1994; 17(5)387–396
  • Heinemann L., Schmelzeisen‐‐Redekeron G. Non invasive continuous glucose monitoring in type 1 diabetic patients with optical glucose sensors. Diabetologia 1998; 41(7)848–854
  • Hoffman A., Ziv E. Pharmacokinetic consideraration of new insulin formulations and route of administration. Clin. Pharmacokinet. 1997; 33(4)285–301
  • Kawamori R., Yamasaki Y., Murata T., Morishima T., Yagi T., Goriya Y., Shichiri M., Abe H. Validation of self‐‐adaptative control algorithm for blood glucose concentration in artificial beta cell. Automedica 1980; 3: 183–189
  • Marvin J. S., Hellinga H. W. Engineering biosensors by introducing fluorescent allosteric signal transducers: construction of a novel glucose sensor. J. Am. Chem. Soc. 1998; 120: 7–11
  • Nomura M., Shichiri M., Kawamori R., Yamasaki Y., Iwama N., Abe H. A mathematical insulin‐‐secretion model and its validation in isolated rat pancreatic islets perfusion. Comput. Biomed. Res. 1984; 17: 570–579
  • Pickup J. Sensitive glucose sensing in diabetes. Lancet 2000; 355: 426–427
  • Pickup J., McCartney L., Rolinski O., Birch D. In vivo glucose sensing for diabetes management: progress towards non‐‐invasive monitoring. BMJ 1999; 319(7220)1289–1295
  • Schaupp, Ellmerer M., Brunner G. A., Wutte A., Sendlhofer G., Trajanoski Z., Skrabal F., Pieber T. R., Wach P. Direct access to interstitial fluid in adipose tissue in humans by use of open‐‐flow microperfusion. Am. J. Physiol., Endocrinol Metabol. Gastrointest. Physiol. 1999; 276: E401–E408
  • Shichiri M., Kawamori R. Optimised algorithms for closet‐‐loop glycemic control system. Computer System for Insulin Adjustment, J. Beyer, M. Albisser, J. Scherezenmeir, L. Lehmann. Diabetes Mellitus, Panscientia‐‐Verlag, Switzerland 1985; 171–183
  • Shichiri M., Kawamori R., Yamasaki Y., Hakui N., Abe H. Wearable artificial endocrine pancreas with needle‐‐type glucose sensor. Lancet 1982; 2: 1129–1131
  • Shichiri M., Kawamori R., Yamazaki Y. Needle‐‐type glucose sensor. Methods Enzymol. 1988; 137: 326–334
  • Tolosa L., Szmacinski H., Rao G., Lakowicz J. R. Lifetime‐‐based sensing of glucose using energy transfer with a long‐‐lifetime donor. Anal. Biochem. 1997; 250: 102–108
  • Trajanoski Z., Brunner G. A., Schaupp L., Ellmerer M., Wach P., Pieber T. R., Kotanko P., Skrabal F. Open‐‐flow microperfusion of subcutaneous adipose tissue for on‐‐line continuous ex vivo measurement of glucose concentration. Diabetes Care 1997; 20: 1114–1121
  • UK Prospective Diabetes Study Group. Intensive blood glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes: UKPDS 33. Lancet 1998; 352: 837–853

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.