484
Views
21
CrossRef citations to date
0
Altmetric
Original

Acetylcholinesterase (AChE) Electrodes Based on Gelatin and Chitosan Matrices for the Pesticide Detection

&
Pages 427-442 | Published online: 11 Jul 2009

References

  • Arkhypova V. N., Dzyadevych S. V., Soldatkin A. P., El'skaya A. V., Jaffrezic-Renault N., Jaffrezic H., Martelet C. Multibiosensor based on enzyme inhibition analysis for determination different toxic substances. Talanta 2001; 55: 919–927
  • Campanella L., Favero G., Persi L., Sammartino M. P., Tomasetti M., Visco G. Organic phase enzyme electrodes: applications and theoretical studies. Anal. Chim. Acta 2001; 426: 235–247, [CROSSREF]
  • Ertaş N., Timur S., Akyılmaz E., Dinçkaya E. Specific determination of hydrogen peroxide a catalase biosensor based on mercury thin film electrodes. Turk. J. Chem. 2000; 24: 95–99
  • Evtugyn G. A., Rizaeva E. P., Stoikova E. E., Latipova V. Z., Budnikov H. C. The application of cholinesterase potantiometric biosensor for preliminary screening of the toxicity of waste waters. Electroanalysis 1997; 9: 1124–1128
  • Farid E. A. Analyses of pesticides and their metabolites in foods and drinks. TrAC Trends in Analytical Chemistry 2001; 20: 649–661, [CROSSREF]
  • Fennouh S., Casimiri V., Burstein V. Increased paraoxon detection with solvents using acetylcholinesterase inactivation measured with a choline oxidase biosensor. Biosens. Bioelectron. 1997; 12: 97–104, [CROSSREF]
  • Forget J., Livet S., Leboulenger F. Partial purification and characterization of acelylcholinestresterase (AChE) from the estuarine copepod Eurytemora affinis (Poppe). Comparative Biochemistry and Physiology Part C: Toxicology of Pharmacology 2002; 132: 85–92, [CROSSREF]
  • Hendji A. M. N., Jaffrezic-Renault N., Martelet C., Clechet P. Sensitive detection of pesticides using a differential ISFET-baset system with immobilized cholinesterase Anal. Chim. Acta 1993; 281: 3–11, [CROSSREF]
  • Hoff G. R., Zoonen P. Trace analysis of pesticides by gas chromatography. J. Chrom A. 1999; 843: 301–322, [CROSSREF]
  • Imato T., Ishibashi N. Potentiometric butyrylcholine sensor for organophosphorus pesticides. Biosens. Bioelectron. 1995; 10: 455–441, [CROSSREF]
  • Ivanov A. N., Evtugyn G. A., Gyurosanyi R. E., Toth K., Budnikov H. C. Comparative investigation of electrochemical cholinesterase biosensors for pesticide determination. Anal. Chim. Acta 2000; 404: 55–65, [CROSSREF]
  • Maye A. H., Miles C. J. Postcolumn photolysis of pesticides for fluorometric determination by HPLC. Anal. Chem. 1988; 60: 220–226
  • Montesinos T., Perez-Munguia S., Valdez F., Marty J. L. Disposable cholinesterase biosensor for the detection of pesticides in water-miscible organic solvents. Anal. Chim. Acta 2001; 431: 231–237, [CROSSREF]
  • Mulchandani A., Chen W., Mulchandani P., Wang J., Rogers K. Biosensors for direct determination of orgonoshosphate pesticides. Biosens. Bioelectron. 2001; 16: 225–230, [PUBMED], [INFOTRIEVE], [CROSSREF]
  • Okazaki S., Nakagawa H., Fukuda K., Asakura S., Kiuchi H., Shigemori T., Takahashi S. Reactivation of an amperometric organophosphate pesticide biosensor by 2-pyridine aldoxime methochloride. Sensors and Actuators B. 2000; 66: 131–134, [CROSSREF]
  • Rekha K., Thakur M. S., Karanth N. G. Biosensors for the detection of organophosphorous pesticides. Critical Reviews in Biotechnology 2000; 20: 213–235, [PUBMED], [INFOTRIEVE]
  • Ristori C., Del Carlo C., Martini M., Barbaro A., Ancarani A. Potentiometric detection of pesticides in water samples. Anal. Chim. Acta 1996; 325: 151–160, [CROSSREF]
  • Rogers K. R., Cao C. J., Valdes J. J., Eldefrawi A. T., Eldefrawi M. E. Acetylcholinesterase fiber-optic biosensor for detection of anticholinesterases. Fundam. Appl. Toxicol. 1991; 16: 810–820, [PUBMED], [INFOTRIEVE], [CROSSREF]
  • Skladal P. Biosensors based on cholinesterase for detection of pesticides. Food Technol. Biotechnol. 1996; 34: 43–49
  • Skadal P., Krejci J. Performance of amperometric biosensor with immobilized butyrylcholinesterase in organic solvents. Collect. Czech. Chem. Commun. 1996; 61: 985–991, [CROSSREF]
  • Wang G., Xu J. J., Ye L. H., Zhu J. J., Chen H. Y. Highly sensitive sensors based on the immobilization of tyrosinase in chitosan. Bioelectrochemistry 2002; 57: 33–38, [PUBMED], [INFOTRIEVE], [CROSSREF]
  • Zihnioğlu F., Telefoncu A. Diffusion characterizatic of chitosan entrapped microsomal UDP-Glucuronyltransferase Gel Beads. Biochimica Biophysica Acta 1995; 1244: 291–294

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.