REFERENCES
- Mills J., Minors D., Waterhouse J. Adaptation to Abrupt Timeshifts of the Oscillator(s) Controlling Human Circadian Rhythms. J. Physiol. (Lond.) 1978; 285: 455–470
- Czeisler C., Brown E., Ronda J., Kronauer R., Richardson G., Freitag W. A Clinical Method to Assess the Endogenous Circadian Phase (ECP) of the Deep Circadian Oscillator in Man. Sleep Res. 1985; 14: 295
- Aschoff J. Masking of Circadian Rhythms by Zeitgebers as Opposed to Entrainment. Trends in Chronobiology, W. Hekkens, G. Kerkhof, W. Rietveld. Oxford University Press/Pergamon Press, Oxford, UK 1988; 149–161
- Minors D., Waterhouse J. Masking in Humans: The Problem and Some Attempts to Solve It. Chronobiol. Int. 1989; 6: 29–53
- Waterhouse J., Weinert D., Minors D., Folkard S., Owens D., Atkinson G., Macdonald I., Sytnik N., Tucker P., Reilly T. A Comparison of Some Different Methods for Purifying Core Temperature Data from Humans. Chronobiol. Int. 2000; 17: 539–566
- Folkard S., Minors D., Waterhouse J. De-masking the Temperature Rhythm After Simulated Time-Zone Transitions. J. Biol. Rhythms 1991; 6: 81–91
- Minors D., Waterhouse J. Investigating the Endogenous Component of Human Circadian Rhythms: A Review of Some Simple Alternatives to Constant Routines. Chronbiol. Int. 1992; 9: 55–78
- Minors D., Akerstedt T., Waterhouse J. The Adjustment of the Circadian Rhythm of Body Temperature to Simulated Time-Zone Transitions. Chronobiol. Int. 1994; 11: 356–366
- Fox R., Goldsmith R., Wolff H. The Use of a Radio Pill to Measure Deep Body Temperature. J. Physiol. (Lond.) 1961; 160: 22–23
- Wolff H. The Radio Pill. New Scientist 1961; 216: 419–421
- Mittal B., Sathiaseelan V., Rademaker A., Pierce M., Johnson P., Brand W. Evaluation of an Ingestible Telemetric Temperature Sensor for Deep Hyperthermia Applications. Int. J. Radiat. Oncol. Biol. Phys. 1991; 21: 1353–1361
- Sparling P., Snow T., Millard-Stafford M. Monitoring Core Temperature During Exercise: Ingestible Sensor vs. Rectal Thermistor. Aviat. Space Environ. Med. 1993; 64: 760–763
- Kolka M., Quigley M., Blanchard L., Toyota D., Stephenson L. Validation of a Temperature Telemetry System During Moderate and Strenuous Exercise. J. Therm. Biol. 1993; 18: 203–210
- Kolka M., Levine L., Stephenson L. Use of an Ingestible Telemetry Sensor to Measure Core Temperature Under Chemical Protective Clothing. J. Therm. Biol. 1997; 22: 343–349
- O'Brien C., Hoyt R., Buller M., Castellani J., Young A. Telemetry Pill Measurement of Core Temperature in Humans During Active Heating and Cooling. Med. Sci. Sports Exerc. 1998; 30: 468–472
- Hamilos D., Nutter D., Gershtenson J., Redmond D., Di Clementi J., Schmaling K., Make B., Jones J. Core Body Temperature Is Normal in Chronic Fatigue Syndrome. Biol. Psychiatr. 1998; 43: 293–302
- Stuart M., Lee M., Williams W., Fortney Schneider S. Core Temperature Measurement During Supine Exercise: Esophageal, Rectal, and Intestinal Temperatures. Aviat. Space Environ. Med. 2000; 71: 939–945
- Gote H., Rasmussen S., Norskov B., Schlichting P. Can Measurements of Oral or Axillary Temperature Replace Rectal Temperature Measurements?. Ugeskr. Laeger 1989; 151: 2085–2087
- Giuffre M., Heidenreich T., Carney-Gersten P., Dorsch J., Heidenreich E. The Relationship Between Axillary and Core Body Temperature Measurements. Appl. Nurs. Res. 1990; 3: 52–55
- Tsujimoto T., Yamada N., Shimoda K., Takahashi S. Circadian Rhythms in Depression. Part I: Monitoring of the Circadian Body Temperature Rhythm. J. Affect. Dis. 1990; 18: 193–197
- Erickson R., Kirklin S. Comparison of Ear-Based, Bladder, Oral, and Axillary Methods for Core Temperature Measurement. Crit. Care Med. 1993; 21: 1528–1534
- Fulbrook P. Core Temperature Measurement: A Comparison of Rectal, Axillary and Pulmonary Artery Blood Temperature. Inten. Crit. Care Nurs. 1993; 9: 217–225
- Yetman R., Coody D., West M., Montgomery D., Brown M. Comparison of Temperature Measurements by an Aural Infrared Thermometer with Measurements Made by Traditional Rectal and Axillary Techniques. J. Pediatr. 1993; 122: 769–773
- Shann F., Mackenzie A. Comparison of Rectal, Axillary, and Forehead Temperatures. Arch. Pediatr. Adolesc. Med. 1996; 150: 74–78
- Zengeya S., Blumenthal I. Modern Electronic and Chemical Thermometers Used in the Axilla Are Inaccurate. Eur. J. Pediatr. 1996; 155: 1005–1008
- Wilshaw R., Beckstrand R., Waid D., Schaalje G. A Comparison of the Use of Tympanic, Axillary, and Rectal Thermometers in Infants. J. Pediatr. Nurs. 1999; 14: 88–93
- Lodha R., Mukerji N., Sinha N., Pandey R., Jain Y. Is Axillary Temperature an Appropriate Surrogate for Core Temperature?. Ind. J. Pediatr. 2000; 67: 571–574
- Bicakova-Rocher A., Reinberg A., Gorceix A., Nougier J., Nougier-Soule J. Rythmes de la Temperature Axillaire: Predominance d'une Periode Ultradienne Lors de Troubles Affectifs Majeurs. C.R. Acad. Sci. 1989; 309: 331–335
- Monge-Strausse M., Bicakova-Rocher A., Mikol F., Garbarg-Chenon L., Reinberg A., Touitou Y. Persistence of a Circadian Rhythm in Axillary Temperature (AT) of Adult Epileptic Patients. Ann. Rev. Chronopharmacol. 1990; 7: 45–48
- Motohashi Y., Reinberg A., Levi F., Nougier J., Benoit O., Foret J., Bourdeleau P. Axillary Temperature: A Circadian Marker for Shift Workers. Ergonomics 1987; 30: 1235–1247
- Bogh M., Minors D., Waterhouse J. Can Insulated Skin Temperature Act as a Substitute for Rectal Temperature when Studying Circadian Rhythms?. Chronobiol. Int. 1994; 11: 332–339
- Minors D., Waterhouse J. Separating the Endogenous and Exogenous Components of the Circadian Rhythm of Body Temperature During Night Work Using Some Purification Models. Ergonomics 1993; 36: 497–507
- Atkinson G., Nevill A. Statistical Methods for Assessing Measurement Error (Reliability) in Variables Relevant to Sports Medicine. Sports Med. 1998; 26: 217–238
- Bland J., Altman D. Measuring Agreement in Method Comparison Studies. Stat. Methods Med. Res. 1999; 8: 135–160
- Nelson W., Tong Y., Lee J., Halberg F. Methods for Cosinor-Rhythmometry. Chronobiologia 1979; 6: 305–323
- Waterhouse J., Minors D., Folkard S. Estimating the Endogenous Component of the Circadian Rhythm of Rectal Temperature in Humans Undergoing Normal Sleep/Activity Schedules. J. Interdisc. Cycle Res. 1993; 24: 197–211
- Waterhouse J., Nevill A., Weinert D., Folkard S., Minors D., Atkinson G., Reilly T., Macdonald I., Owens D., Sytnik N., Tucker P. Modelling the Effect of Spontaneous Activity on Core Temperature in Healthy Human Subjects. Biol. Rhythm Res. 2001, in press
- Bicakova-Rocher A., Gorceix A., Reinberg A., Ashkenazi I., Ticher A. Temperature Rhythm of Patients with Major Affective Disorders: Reduced Circadian Period Length. Chronobiol. Int. 1996; 13: 47–57
- Weinert D., Waterhouse J. Diurnally Changing Effects of Locomotor Activity on Body Temperature in Laboratory Mice. Physiol. Behav. 1998; 63: 837–843
- Weinert D., Sitka U., Minors D., Waterhouse J. The Development of Circadian Rhythmicity in Neonates. Early Hum. Dev. 1994; 36: 117–126
- Weinert D., Sitka U., Minors D., Menna-Barreto L., Waterhouse J. Twenty-Four-Hour and Ultradian Rhythmicities in Healthy Full-Term Neonates: Exogenous and Endogenous Influences. Biol. Rhythm Res. 1997; 28: 441–452