97
Views
9
CrossRef citations to date
0
Altmetric
Original Articles

Development of Liposome Immune Lysis Assay for the Herbicide Atrazine

, , , &
Pages 279-294 | Received 30 Nov 2003, Accepted 18 Dec 2003, Published online: 23 Aug 2007

References

  • Hage , D. S. 1999 . Immunoassays . Anal. Chem. , 71 ( 12 ) : 294R – 304R . [PUBMED] [INFOTRIEVE]
  • Hennion , M.‐C. and Barcelo , D. 1998 . Strength and limitations of immunoassays for effective and efficient use for herbicide analysis in water samples: a review . Anal. Chim. Acta , 362 ( 1 ) : 3 – 34 . [CROSSREF] [CSA]
  • Butler , J. E. 2000 . Enzyme‐linked immunosorbent assay . J. Immunoassay , 21 ( 2–3 ) : 165 – 209 . [PUBMED] [INFOTRIEVE] [CSA]
  • Kinsky , S. C. 1972 . Antibody‐complement interaction with lipid model membranes . Biochim. Biophys. Acta , 265 ( 1 ) : 1 – 23 . [PUBMED] [INFOTRIEVE]
  • Kinsky , S. C. 1974 . Preparation of liposomes and a spectrophotometric assay for release of trapped glucose marker . Methods Enzymol. , 32 ( B ) : 501 – 513 . [PUBMED] [INFOTRIEVE]
  • Yasuda , T. , Naito , Y. , Tsumita , T. and Tadakuma , T. 1981 . A simple method to measure anti‐glycolipid antibody by using complement‐mediated immune lysis of fluorescent dye‐trapped liposomes . J. Immunol. Methods , 44 ( 2 ) : 153 – 158 . [PUBMED] [INFOTRIEVE] [CROSSREF]
  • Ishimori , Y. , Yasuda , T. , Tsumita , T. , Notsuki , M. , Koyama , M. and Tadakuma , T. 1984 . Liposome immune lysis assay (LILA): a simple method to measure anti‐protein antibody using protein antigen‐bearing liposomes . J. Immunol. Methods , 75 ( 2 ) : 351 – 360 . [PUBMED] [INFOTRIEVE] [CROSSREF]
  • Yamamoto , S. , Kubotsu , K. , Kida , M. , Kondo , K. , Matsuura , S. , Uchiyama , S. , Yonekawa , O. and Kanno , T. 1995 . Automated homogeneous liposome‐based assay system for total complement activity . Clin. Chem. , 41 ( 4 ) : 586 – 590 . [PUBMED] [INFOTRIEVE] [CSA]
  • Kim , C. K. and Lim , S. J. 1993 . Liposome immunoassay (LIA) with antigen‐coupled liposomes containing alkaline phosphatase . J. Immunol. Methods , 159 ( 1–2 ) : 101 – 106 . [PUBMED] [INFOTRIEVE] [CROSSREF] [CSA]
  • Singh , A. K. , Kilpatrick , P. K. and Carbonell , R. G. 1995 . Noncompetitive immunoassays using bifunctional unilamellar vesicles or liposomes . Biotechnol. Prog. , 11 ( 3 ) : 333 – 341 . [PUBMED] [INFOTRIEVE] [CSA]
  • Kumada , Y. , Maehara , M. , Tomioka , K. and Katoh , S. 2002 . Liposome immunoblotting assay using a substrate‐forming precipitate inside immunoliposomes . Biotechnol. Bioeng. , 80 ( 4 ) : 414 – 418 . [PUBMED] [INFOTRIEVE] [CROSSREF] [CSA]
  • Edwards , A. J. and Durst , R. A. 1995 . Flow‐injection liposome immunoanalysis (FILIA) using electrochemical detection . Electroanalysis , 7 : 838 – 843 .
  • Hsia , J. C. and Tan , C. T. 1978 . Membrane immunoassay: principle and applications of spin membrane immunoassay . Ann. NY Acad. Sci. , 308 : 139 – 148 . [PUBMED] [INFOTRIEVE]
  • Umeda , M. , Ishimori , Y. , Yoshikawa , K. , Takada , M. and Yasuda , T. 1986 . Liposome immune lysis assay (LILA). Application of sandwich method to determine a serum protein component with antibody‐bearing liposomes . J. Immunol. Methods , 95 ( 1 ) : 15 – 21 . [PUBMED] [INFOTRIEVE] [CROSSREF]
  • Lelkes , P. I. 1984 . “ Methodological aspects dealing with stability measurements of liposomes in vitro using the carboxyfluorescein‐assay ” . In Liposome Technology Edited by: Gregoriadis , G. Vol. III , 225 Boca Raton , FL : CRC Press .
  • Hosoda , K. and Yasuda , T. 1989 . Homogeneous immunoassay for alpha 2 plasmin inhibitor (Alpha 2PI) and alpha 2PI‐plasmin complex. Application of a sandwich liposome immune lysis assay (LILA) technique . J. Immunol. Methods , 121 ( 1 ) : 121 – 128 . [PUBMED] [INFOTRIEVE] [CROSSREF] [CSA]
  • Geiger , B. and Smolarsky , M. 1977 . Immunochemical determination of ganglioside GM2, by inhibition of complement‐dependent liposome lysis . J. Immunol. Methods , 17 ( 1–2 ) : 7 – 19 . [PUBMED] [INFOTRIEVE] [CROSSREF]
  • Kobayashi , K. , Watarai , S. and Yasuda , T. 1992 . Sensitive detection of ganglioside GD3 on the cell surface using liposome immune lysis assay . Acta Med. Okayama , 46 ( 6 ) : 435 – 441 . [PUBMED] [INFOTRIEVE]
  • Skopinskaya , S. N. , Tamulevich , Yu. A. , Yarkov , S. P. , Zlobin , V. N. and Kalinin , Yu. T. 1993 . Highly sensitive homogeneous method for the determination of antibodies and antigens by means of liposomes, monoclonal antibodies and complement . Zh. Mikrobiol. Epidemiol. Immunobiol. , 1 : 77 – 82 . (in Russian)
  • Legros , F. , Schietecat , P. , Leroy , C. P. and Van Vooren , J. P. 1989 . An automated micromethod for detection of lytic antimycobacterial antibodies by immune lysis of liposomes sensitized to tuberculin . J. Immunoassay , 10 ( 4 ) : 359 – 372 . [INFOTRIEVE]
  • Tomioka , K. , Kii , F. , Fukuda , H. and Katoh , S. 1994 . Homogeneous immunoassay of antibody by use of liposomes made of a model lipid of archaebacteria . J. Immunol. Methods , 176 ( 1 ) : 1 – 7 . [PUBMED] [INFOTRIEVE] [CROSSREF] [CSA]
  • Okada , N. , Yasuda , T. , Tsumita , T. and Okada , H. 1982 . Activation of the alternative complement pathway of guinea‐gip by liposomes incorporated with trinitrophenylated phosphatidylethanolamine . Immunology , 45 ( 1 ) : 115 – 124 . [PUBMED] [INFOTRIEVE]
  • Ligler , F. S. , Bredehorst , R. , Talebian , A. , Shriver , L. C. , Hammer , C. F. , Sheridan , J. P. , Vogel , C. W. and Gaber , B. P. 1987 . A homogeneous immunoassay for the mycotoxin T‐2 utilizing liposomes, monoclonal antibodies, and complement . Anal. Biochem. , 163 ( 2 ) : 369 – 375 . [PUBMED] [INFOTRIEVE] [CROSSREF]
  • Paul , A. , Madan , S. , Vasandani , V. M. , Ghosh , P. C. and Bachhawat , B. K. 1992 . Liposome immune lysis assay (LILA) for gelonin . J. Immunol. Methods , 148 ( 1–2 ) : 151 – 158 . [PUBMED] [INFOTRIEVE] [CROSSREF] [CSA]
  • Kubotsu , K. , Goto , S. , Fujita , M. , Tuchiya , H. , Kida , M. , Takano , S. , Matsuura , S. and Sakurabayashi , I. 1992 . Automated homogeneous liposome immunoassay systems for anticonvulsant drugs . Clin. Chem. , 38 ( 6 ) : 808 – 812 . [PUBMED] [INFOTRIEVE]
  • Yamamoto , S. , Kubotsu , K. , Kida , M. , Kondo , K. , Matsuura , S. , Uchiyama , S. , Yonekawa , O. and Kanno , T. 1995 . Automated homogeneous liposome‐based assay system for total complement activity . Clin. Chem. , 41 ( 4 ) : 586 – 590 . [PUBMED] [INFOTRIEVE] [CSA]
  • Skopinskaya , S. N. , Yarkov , S. P. and Rubtsov , I. V. 1990 . Determination of antibodies to group B Salmonella and their somatic O‐antigen by complement‐dependent lysis of liposomes . Zh. Mikrobiol. Epidemiol. Immunobiol. , 4 : 84 – 88 . (in Russian)
  • Yarkov , S. P. , Skopinskaya , S. N. , Rubtsov , I. V. , Lvova , M. and Milyutina , L. N. 1990 . Quantitative analysis of lipopilysaccharide (LPS) antigen in the blood sera of salmonellosis patients using complement‐depending liposome lysis . Zh. Mikrobiol. Epidemiol. Immunobiol. , 5 : 65 – 69 . (in Russian)
  • Yarkov , S. P. , Skopinskaya , S. N. and Milyutina , L. N. 1997 . Liposomal immunoassay—a new method of salmonellosis diagnostics . Immunol. , 4 : 59 – 62 . (in Russian)
  • Skopinskaya , S. N. , Yarkov , S. P. and Khramov , E. N. 2001 . Design and properties of bifunctional reagent basing on liposome sensitized by bacterial antigens . Immunologiya , 3 : 54 – 59 . (in Russian)
  • Dzantiev , B. B. , Zherdev , A. V. , Romanenko , O. G. and Sapegova , L. A. 1996 . Development and comparative study of different immunoenzyme techniques for pesticides detection . Int. J. Environ. Anal. Chem. , 65 ( 1–4 ) : 95 – 111 . [CSA]
  • Starodub , N. F. , Dzantiev , B. B. , Starodub , V. M. and Zherdev , A. V. 2000 . Immunosensor for the determination of the herbicide simazine based on a ion‐selective field‐effect transistor . Anal. Chim. Acta , 424 : 37 – 43 . [CROSSREF]
  • Bergelson , L. D. , Dyatlovitskaya , E. V. and Molotkovsky , Yu. G. 1981 . Preparative Biochemistry of Lipids 256 Moscow : Nauka . (in Russian)
  • Szoka , F. and Papahadjopoulos , D. 1978 . Procedure for preparation of liposomes with large internal aqueous space and high capture by reverse‐phase evaporation . Proc. Natl Acad. Sci. USA , 75 ( 9 ) : 4194 – 4198 . [PUBMED] [INFOTRIEVE]
  • Barlett , G. 1959 . Phosphorus assay in column chromatography . J. Biol. Chem. , 234 ( 3 ) : 466 – 468 .
  • Ohsawa , T. , Miura , H. and Harada , K. 1985 . Studies on the effect of water‐soluble additives and on the encapsulation mechanism in liposome preparation by the freeze‐thawing method . Chem. Pharm. Bull. (Tokyo) , 33 ( 12 ) : 5474 – 5483 .
  • Skopinskaya , S. N. , Yarkov , S. P. , Khramov , V. N. and Zlobin , V. N. 2000 . Sulforhodamine 101: novel effective marker for liposomal immunoassay . Vest. Ross. Akad. Med. Nauk , 10 : 19 – 24 . (in Russian)
  • New , R. R.C. 1990 . “ Preparation of liposomes ” . In Liposomes: a Practical Approach Edited by: New , R. R.C. 33 – 104 . Oxford : Oxford University Press .
  • Frost , S. J. , Firth , G. B. and Chakraborty , J. 1994 . A novel colourimetric homogeneous liposomal immunoassay using sulforhodamine B . J. Liposome Res. , 4 : 1159 – 1182 .
  • Rongen , H. A. , Bult , A. and van Bennekom , W. P. 1997 . Liposomes and immunoassays . J. Immunol. Methods , 204 ( 2 ) : 105 – 133 . [PUBMED] [INFOTRIEVE] [CROSSREF] [CSA]
  • Vistnes , A. I. 1988 . “ Membrane immunoassay in serology ” . In Nonisotopic Immunoassay Edited by: Ngo , T. 361 – 388 . New York , NY : Marcel Dekker, Inc. .
  • Richards , R. A. , Habbersett , B. C. , Scher , I. , Janoff , A. S. , Sclieren , R. P. , Meyer , L. D. , Cullis , P. R. and Alving , C. R. 1986 . Influence of vesicle size on complement‐dependent immune damage to liposomes . Biochim. Biophys. Acta , 855 ( 2 ) : 223 – 228 . [PUBMED] [INFOTRIEVE]

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.