References
- Massart , D. L. , Vandeginste , B. G.M. , Buydens , L. M.C. , De Jong , S. , Lewi , P. J. and Smeyers‐Verbeke , J. 1998 . Handbook of Chemometrics and Qualimetrics: Part A Amsterdam : Elsevier .
- Castells , R. C. and Castillo , M. A. 2000 . Systematic errors: detection and correction by means of standard calibration, Youden calibration and standard addition method in conjunction with a method response model . Anal. Chim. Acta , 423 : 179 – 185 .
- Navarro‐Villoslada , F. , Pérez‐Arribas , L. V. , León‐González , M. E. and Polo‐Díez , L. M. 1999 . Matrix effect modelling in multivariate determination of priority pollutant chlorophenols in urine samples . Anal. Chim. Acta , 381 : 93 – 102 .
- Mauri , A. R. , Llobat , M. and Adria , D. 2001 . Detection and correction of interfaces in spectroscopy techniques . Anal. Chim. Acta , 426 : 135 – 146 .
- Youden , W. J. 1947 . Technique for testing the accuracy of analytical data . Anal. Chem. , 19 : 946 – 950 .
- Cardone , M. J. 1983 . Detection and determination of error in analytical methodology. 1. In the method verification program . J. AOAC , 66 : 1257 – 1282 .
- Cardone , M. J. 1983 . Detection and determination of error in analytical methodology. 2. Correction for corrigible systematic‐error in the course of real sample analysis . J. AOAC , 66 : 1283 – 1294 .
- Erney , D. R. , Gillespie , A. M. , Gylvidis , D. M. and Poole , C. F. 1993 . Explanation of the matrix‐induced chromatographic response enhancement of organophosphorus pesticides during open tubular column gas chromatography with splitless or hot on‐column injection and flame photometric detection . J. Chromatogr. A , 638 : 57 – 63 .
- Erney , D. R. , Pawlowski , T. M. and Poole , C. F. 1997 . Matrix‐induced peak enhancement of pesticides in gas chromatography. Is there a solution? . J. High Resolut. Chromatogr. , 20 : 375 – 378 .
- Hajslová , J. , Holadová , K. , Kocourek , V. , Poustka , J. , Godula , M. , Cuhra , P. and Kempný , M. 1998 . Matrix‐induced effects a critical point in the gas chromatographic analysis of pesticide residues . J. Chromatogr. A , 800 : 283 – 295 .
- Egea González , F. J. , Hernández Torres , M. E. , Almansa López , E. and Cuadros Rodríguez , L. 2002 . Estimation and correction of matrix effects in gas chromatographic pesticide multiresidue methods with nitrogen‐phosphorus detector . The Analyst , 127 : 1038 – 1044 .
- Lehotay , S. J. and Eller , K. I. 1995 . Development of a method of analysis for 46 pesticides in fruits and vegatables by supercritical‐fluid extraction and gas‐chromatography ion‐trap mass‐spectrometry . J. AOAC Int. , 78 : 821 – 830 .
- Johnson , P. D. , Rimmer , D. A. and Brown , R. H. 1997 . Adaptation and application of a multi‐residue method for the determination of a range of pesticides, including phenoxy acid herbicides in vegetation, used on high‐resolution gel permeation chromatographic clean‐up and gas chromatographic analysis with mass‐selective detection . J. Chromatogr. A , 765 : 3 – 11 .
- Anastassiades , M. and Scherbaum , E. 1997 . Multiresidue method for determination of pesticide residues in citrus fruits by GC‐MSD . Deutsche Lebensmittel Rundschau , 93 ( 10 ) : 316 – 327 .
- Lehotay , S. J. 2000 . Analysis of pesticide residues in mixed fruit and vegetable extracts by direct sample introduction/gas chromatography/tandem mass spectrometry . J. AOAC Int. , 83 ( 3 ) : 680 – 697 .
- Barnes , A. , Fusell , J. R. , Startin , J. R. , Thorpe , S. A. and Reynols , S. L. 1995 . Determination of the pesticides diflubenzuroon and clofentezine in plums, strawberries and black‐currant‐based fruit drinks by high‐performance liquid‐chromatographic atmospheric‐pressure chemical‐ionization mass‐spectrometry . Rapid Commun. in Mass Spectrom. , 9 ( 14 ) : 1441 – 1445 .
- Fu , I. , Woolf , E. J. and Matuszewski , B. K. 1998 . Effect of the sample matrix on the determination of indinavir in human urine by HPLC with turbo ion spray tandem mass spectrometric detection . J. of Pharmac. and Biomed. Anal. , 18 : 347 – 357 .
- Choi , B. K. , Hercules , D. M. and Gusev , A. I. 2001 . Effect of liquid chromatography separation of complex matrices on liquid chromatography‐tandem mass spectrometry signal suppression . J. Chromatogr. A , 907 : 337 – 342 .
- Egea González , F. J. , Castro Cano , M. L. , Martínez Vidal , J. L. , Glass , C. R. and Cruz Márquez , M. 1999 . Analytical method for assessing exposure of greenhouse applicators to procymidone by gas chromatography and whole body dosymetry . Chromatographia , 50 ( 6 ) : 293 – 298 .
- Dijkman , E. , Mooibroek , D. , Hoogerbrugge , R. , Hogendoorn , E. , Sancho , J. V. , Pozo , O. and Hernández , F. 2001 . Study of matrix effects on the direct trace analysis of acidic pesticides in water using various liquid chromatographic modes coupled to tandem mass spectrometric detection . J. Chromatogr. A , 926 : 113 – 125 .
- Martínez Galera , M. , López López , T. , Gil García , M. D. , Martínez Vidal , J. L. and Parrilla Vázquez , P. 2001 . Determination of benzoylureas in tomato by high‐performance liquid chromatography using continuous on‐line post‐elution photoirradiation with fluorescence detection . J. Chromatogr. A , 918 : 79 – 85 .
- López López , T. , Gil García , M. D. , Martínez Vidal , J. L. and Martínez Galera , M. 2001 . Determination of pyrethoids in vegetables by HPLC using continuous on‐line post‐elution photoirradiation with fluorescence detection . Anal. Chim. Acta , 447 : 101 – 111 .
- Schenck , F. J. and Lehotay , S. J. 2000 . Does further clean‐up reduce the matrix enhancement effect in gas chromatographic analysis of pesticide residues in food? . J. Chromatogr. A , 868 : 51 – 61 .
- Di Muccio , A. , Girolimetti , S. , Barbini , D. A. , Pelosi , P. , Generali , T. , Vergori , L. , De Merulis , G. , Leonelli , A. and Stefanelli , P. 1999 . Selective clean‐up applicable to aqueous acetone extracts for the determination of carben‐dazim and thiabendazole in fruits and vegetables by high‐performance liquid chromatography with UV detection . J. Chromatogr. A , 833 : 61 – 65 .
- Hill , A. R.C. 1997 . “ A Quality Control Procedures for Pesiticide Residue Analysis ” . European Commission document 7826/VI/97
- Holland , P. T. , McNaughton , D. E. and Malcolm , C. 1994 . Multiresidue analysis of pesticides in wines by solid‐phase extraction . J. AOAC Int. , 77 : 79 – 86 .
- Fillion , J. , Hindle , R. W. , Lacroix , M. D. and Selwyn , J. 1995 . Multiresidue determination of pesticides in fruit and vegetables by gas chromatography mass‐selective detection and liquid chromatography with fluorescence detection . J. AOAC Int. , 78 : 1252 – 1266 .
- Erney , D. 1995 . Determination of organophosphorus pesticides in whole choc‐olate skim‐milk and infant formula using solid‐phase extraction with capillary gas‐chromatography flame photometric detection . J. High Resol. Chromatogr. , 18 : 59 – 62 .
- de Kok , A. , Vreeker , K. , Hiemstra , M. , Toonen , A. , Besamusca , E. , Van der Meij , J. and Joosten , J. Poster Abstract 43, 8th Annual California Pesticide Residue Workshop . March 10–14 . March . San Francisco , CA
- Mol , H. , Althuizen , M. , Janssen , H. , Cramers , C. and Brinkman , U. 1996 . Environmental applications of large volume injection in capillary GC using PTV injectors . J. High Resol. Chromatogr. , 19 : 69 – 79 .
- Otto , M. 1999 . Chemometrics Weinheim , , Germany : Wiley‐VCH .
- Cuadros Rodríguez , L. , García Campan˜a , A. M. , Almansa López , E. , Egea González , F. J. and Martínez Vidal , J. L. 2002 . On the correction of estimates from external calibration in routine analysis of real samples when matrix effect is distorbing . Anal. Chim. Acta , submitted for publication
- García Campan˜a , A. M. , Cuadros Rodríguez , L. , Aybar Mun˜oz , J. and Alés Barrero , F. 1997 . Chemometric protocol to validate an analytical meted in the presence of corrigible constant and propostional systematic errors . J. AOAC Int. , 80 : 657 – 664 .
- Barnes , K. A. , Fussell , R. J. , Startin , J. R. , Pegg , M. K. , Thorpe , S. A. and Reynolds , S. L. 1997 . High‐performance liquid chromatography atmospheric pressure chemical ionization mass spetrometry with ionization polarity switching for the detection of selected pesticides . Rapid Commun. in Mass Spectrom. , 11 : 117 – 123 .
- Huber , L. 1998 . Validation of analytical methods: review and strategy . LC‐GC Int , 11 : 96 – 105 .
- Accreditation for Chemical Laboratories: Guidance on the interpretation of the EN 45000 series of Standards and ISO/IEC Guide 25 UK EURACHEM Guidance Document No. 1. WELAC Guidance Document No. WGD 2., 1993, EURACHEM Secretariat, PO Box 46, Teddington, Middlesex, TW11 ONH