82
Views
12
CrossRef citations to date
0
Altmetric
Papers

Infection control guidelines for optometrists 2007

, BScOptom PhD PGCertOcTher, , BOptom PGCertOcTher, , MScOptom MPH PhD PGCertOcTher & , BScOptom PhD
Pages 434-444 | Received 07 Apr 2007, Accepted 29 May 2007, Published online: 15 Apr 2021

REFERENCES

  • Jacobs RJ. Infection control guidelines for optometrists and contact lens practitioners. Clin Exp Optom 1986; 69: 40–45.
  • Cockburn DM, Lindsay RG. Infection control guidelines for optometric practice. Clin Exp Optom 1995; 78: 110–112.
  • National Health & Medical Research Council/Australian National Council on AIDS 1996. Infection control in the health care setting: Guidelines for the Prevention of Transmission of Infectious Diseases. AGPS Canberra, 1996.
  • Fujikawa LS, Salahuddin SZ, Ablashi D, Palestine AG, Masur H, Nussenblatt RB, Gallo RC. Htlv‐iii in the tears of AIDS patients. Ophthalmology 1986; 93: 1479–1481.
  • Tervo T, Lahdevirta J, Vaheri A, Valle SL, Suni J. Recovery of htlv‐iii from contact lenses. Lancet 1986; 1: 379–380.
  • Cantrill HL, Henry K, Jackson B, Erice A, Ussery FM, Balfour HH Jr. Recovery of human immunodeficiency virus from ocular tissues in patients with acquired immune deficiency syndrome. Ophthalmology 1988; 95: 1458–1462.
  • Tillman T, Klotz SA, Maino JH. Preventing transmission of infectious diseases including the human immunodeficiency virus in the practice of optometry. J Am Optom Assoc 1992; 63: 18–20.
  • Centers for Disease Control and Prevention. HIV and its transmission. http://www.cdc.gov/hiv/resources/factsheets/transmission.htm (accessed February 2007).
  • Moniz E, Feldman F, Newkirk M, Feinman SV, Berris B. Removal of hepatitis B surface antigen from a contaminated applanation tonometer. Am J Ophthalmol 1981; 91: 522–525.
  • Darrell RW, Jacob GB. Hepatitis B surface antigen in human tears. Arch Ophthalmol 1978; 96: 674–676.
  • Klug GM, Boyd A, Lewis V, Douglass SL, Argent R, Lee JS, Masters CL, Collins SJ. Australian National Creutzfeldt‐Jakob Disease Registry. Creutzfeldt‐Jakob disease: Australian surveillance update to December 2005. Commun Dis Intell 2006; 30: 144–147.
  • Armstrong RA. Creutzfeldt‐Jakob disease and vision. Clin Exp Optom 2006; 89: 3–9.
  • Gordon YJ, Gordon RY, Romanowski E, Araullo‐cruz TP. Prolonged recovery of desiccated adenoviral serotypes 5, 8, and 19 from plastic and metal surfaces in vitro. Ophthalmology 1993; 100: 1835–1839.
  • Semes L. Infection control for ophthalmic patient‐care items. Rev Optom Supp 1997 (The 1997 Clinical Guide to Ophthalmic drugs), 48A.
  • Australian Government Department of Health and Ageing (DHA). Infection control guidelines for the prevention of transmission of infectious diseases in the health care setting. January 2004. http://www.health.gov.au/internet/wcms/publishing.nsf/Content/icg‐guidelines‐index.htm (accessed February 2007).
  • Larson E. Skin hygiene and infection prevention: More of the same or different approaches? Clin Infect Dis 1999; 29: 1287–1294.
  • Pittet D, Hugonnet S, Harbarth S, Mourouga P, Sauvan V, Touveneau S, Perneger, TV. Effectiveness of a hospital‐wide programme to improve compliance with hand hygiene. Infection control programme. Lancet 2000; 356: 1307–1312.
  • Centers for Disease Control and Prevention (CDC) Guideline for Hand Hygiene in Health‐Care Settings 2002. http://www.cdc.gov (accessed February 2007).
  • Doebbeling BN, Stanley GL, Sheetz CT, Pfaller MA, Houston AK, Annis L, Li N, Wenzel RP. Comparative efficacy of alternative hand‐washing agents in reducing nosocomial infections in intensive care units. N Engl J Med 1992; 327: 88–93.
  • World Health Organization Guidelines on Hand Hygiene in Health Care (Advanced Draft), p 101. http://www.who.int/patientsafety/information_centre/ghhad_download/en/index.html (accessed February 2007).
  • Rotter ML, Simpson RA, Koller W. Surgical hand disinfection with alcohols at various concentrations: Parallel experiments using the new proposed European standards method. Infect Control Hosp Epidemiol 1998; 19: 778–781.
  • Sartor C, Jacomo V, Duvivier C, Tissot‐dupont H, Sambuc R, Drancourt M. Nosocomial serratia marcescens infections associated with extrinsic contamination of a liquid nonmedicated soap. Infect Control Hosp Epidemiol 2000; 21: 196–199.
  • Lowbury EJ, Lilly HA. Use of 4 per cent chlorhexidine detergent solution (hibiscrub) and other methods of skin disinfection. Br Med J 1973; 1: 510–515.
  • Voss A, Widmer AF. No time for handwashing!? Handwashing versus alcoholic rub: Can we afford 100% compliance? Infect Control Hosp Epidemiol 1997; 18: 205–208.
  • Storer E, Marshman G, Kupa A. Contact dermatitis to alcohol swabs masquerading as vaccine allergy. Australas J Dermatol 2004; 45: 149–150.
  • Bousquet J, Flahault A, Vandenplas O, Ameille J, Duron JJ, Pecquet C, Chevrie K, Annesi‐maesano I. Natural rubber latex allergy among health care workers: a systematic review of the evidence. J Allergy Clin Immunol 2006; 118: 447–454.
  • Centers for Disease Control and Prevention. http://www.cdc.gov (accessed February 2006).
  • US Food and Drug Administration. http://www.fda.gov (accessed February 2006).
  • Australian Government Department of Health and Ageing: Therapeutic Goods Administration, 2004. Reducing public health risks associated with reusable medical devices. http://www.tga.gov.au/devices/reusdev_phr.pdf (accessed September 2006).
  • International Organization for Standardization ISO/TS 19979. Ophthalmic optics—contact lenses—Hygienic management of multipatient use trial contact lenses. 2004.
  • Callender MG, Charles AM, Chalmers RL. Effect of storage time with different lens care systems on in‐office hydrogel trial lens disinfection efficacy: A multi‐center study. Optom Vis Sci 1992; 69: 678–684.
  • Simmons PA, Edrington TB, Lao KF, Concepcion LL. The efficacy of disinfection systems for in‐office storage of hydrogel contact lenses. ICLC 1996; 23: 94–97.
  • Smith CA, Pepose JS. Disinfection of tonometers and contact lenses in the office setting: are current techniques adequate? Am J Ophthalmol 1999; 127: 77–84.
  • Janoff LE. The exposure of various polymers to a 24‐hour soak in Lensept: The effect on base curve. J Am Optom Assoc 1985; 56: 222–225.
  • Rosenthal RA, Stein JM, Mcnally CL, Schlech BA. A comparative study of microbiologic effectiveness of chemical disinfectants and peroxide‐neutralizer systems. CLAO J 1995; 21: 99–110.
  • Centers for Disease Control. Recommendations for preventing possible transmission of human t‐lymphotrophic virus type iii/lymphadenopathy‐associated virus from tears. MMWR 1985; 34: 533–534.
  • Bergenske PD. Contact lens disinfection. Optom Clin 1994; 4: 47–60.
  • The College of Optometrists, The Association of British Dispensing Opticians. Guidance on the Re‐use of Contact Lenses and Ophthalmic Devices. http://www.college‐optometrists.org/objects_store/cjd.pdf (accessed May 2007).
  • American Academy of Ophthalmology 2002. Minimizing Transmission of Bloodborne Pathogens and Surface Infectious Agents in Ophthalmic Offices and Operating Rooms. http://www.aao.org/education/library/statements/transmission.cfm (accessed September 2006).
  • Segal WA, Pirnazar JR, Arens M, Pepose JS. Disinfection of Goldmann tonometers after contamination with hepatitis C virus. Am J Ophthalmol 2001; 131: 184–187.
  • Su CS, Bowden S, Fong LP, Taylor HR. Current tonometer disinfection may be inadequate for hepatitis B virus. Arch Ophthalmol 1994; 112: 1406–1407.
  • Pepose JS, Linette G, Lee SF, Macrae S. Disinfection of Goldmann tonometers against human immunodeficiency virus type 1. Arch Ophthalmol 1989; 107: 983–985.
  • Rutala WA, Peacock JE, Gergen MF, Sobsey MD, Weber DJ. Efficacy of hospital germicides against adenovirus 8, a common cause of epidemic keratoconjunctivitis in health care facilities. Antimicrob Agents Chemother 2006; 50: 1419–1424.
  • Threlkeld AB, Froggatt JW 3rd, Schein OD, Forman MS. Efficacy of a disinfectant wipe method for the removal of adenovirus 8 from tonometer tips. Ophthalmology 1993; 100: 1841–1845.
  • Lingel NJ, Coffey B. Effects of disinfecting solutions recommended by the Centers for Disease Control on Goldmann tonometer biprisms. J Am Optom Assoc 1992; 63: 43–48.
  • Chronister CL, Cross BT. Structural alteration of tonometer tips after repeated swabbing with disinfectants. Optom Vis Sci 1994; 71: 290–292.
  • Van buskirk EM. Disinfectant receptacle for applanation tonometers. Am J Ophthalmol 1987; 104: 307–308.
  • Lim R, Dhillon B, Kurian KM, Aspinall PA, Fernie K, Ironside JW. Retention of corneal epithelial cells following Goldmann tonometry: implications for CJD risk. Br J Ophthalmol 2003; 87: 583–586.
  • Haag‐Streit International. Goldmann Applanation Tonometer Instruction Manual. http://www.haag‐streit.com/cgi/solutions/index.asp?section=Solutions&page=intro (accessed May 2007).
  • Volk Optical Inc. Cleaning & Care. http://www.volk.com/help‐cleaningandcare.aspx (accessed May 2007).
  • Uchio E, Ishiko H, Aoki K, Ohno S. Adenovirus detected by polymerase chain reaction in multidose eyedrop bottles used by patients with adenoviral keratoconjunctivitis. Am J Ophthalmol 2002; 134: 618–619.
  • Palmberg R, Gutierrez YS, Miller D, Feuer WJ, Anderson DR. Potential bacterial contamination of eyedrops used for tonometry. Am J Ophthalmol 1994; 117: 578–582.
  • National Health and Medical Research Council (NHMRC). National Guidelines for Waste Management in the Health Care Industry, 1999.
  • Rutala WA, White MS, Gergen MF, Weber DJ. Bacterial contamination of keyboards: efficacy and functional impact of disinfectants. Infect Control Hosp Epidemiol 2006; 27: 372–377.
  • North East Valley Division of General Practice. http://www.nevdgp.org.au/info/division/needlestick_injury_what_to_do.htm (accessed November 2006).
  • Australian Government Department of Health and Ageing. Guidelines for the Prevention and Control of Influenza Outbreaks in Residential Care Facilities in Australia 2005. http://www.health.gov.au (accessed May 2007).
  • Australian Government Department of Health and Ageing. Interim Infection Control Guidelines for Pandemic Influenza in Healthcare and Community Settings 2006. http://www.health.gov.au (accessed September 2006).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.