Publication Cover
Neurological Research
A Journal of Progress in Neurosurgery, Neurology and Neurosciences
Volume 24, 2002 - Issue 6
87
Views
67
CrossRef citations to date
0
Altmetric
Articles

Feasibility and limitations of magnetoencephalographic detection of epileptic discharges: Simultaneous recording of magnetic fields and electrocorticography

, , , , , , & show all
Pages 531-536 | Published online: 02 Dec 2013

References

  • Cuffin BN, Cohen D. Comparison of the magnetoencephalogram and electroencephalogram. Electroenceph Clin Neurophysiol 1979; 47: 132–146
  • Rose DF, Smith PD, Sato S. Magnetoencephalographyand epilepsy research. Science 1987; 238: 329–335
  • Stefan H, SchneiderS, Abraham-Fuchs K, Bauer J, Feistel H, Pawlik G, Neubauer U, Röhrlein G, Huk WJ. Magnetic source localization in focal epilepsy. Brain 1990; 113: 1347–1359
  • Paetau R, Kajola M, Karhu J, Nousiainen U, Partanen J, Tiihonen J, Vapalahti M, Hari R. Magnetoencephalographic localization of epileptic cortex — impact on surgical treatment. Ann Neurol 1992; 32: 106–109
  • Balish M, Sato 5, Connaughton P, Kufta C. Localization of implanted dipoles by magnetoencephalography. Neurology 1991; 41: 1072–1076
  • Cohen D, Cuffin BN, Yunokuchi K, Maniewski R, Purcell C, Cosgrove GR, Ives J, Kennedy JG, Schomer DL. MEG versus EEG localization test using implanted source in the human brain. Ann Neurol 1990; 28: 811–817
  • Rose DF, Sato 5, Ducla-Soares E, Kufta CV. Magnetoencephalo-graphic localization of subdural dipoles in a patient with temporal lobe epilepsy. Epilepsia 1991; 32: 635–641
  • Yamamoto T, Williamson Si, Kaufman L, Nicholson C, Llinás R. Magnetic localization of neural activity in the human brain. Proc Natl Acad Sci USA 1988; 85: 8732–8736
  • Baumgartner C, Pataraia E, Lindinger G, Deecke L. Neuromagnetic recordings in temporal lobe epilepsy. J Clin Neurophysiol 2000; 17: 177–189
  • Brockhaus A, Lehnertz K, Wienbruch C, Kowalik A, Burr W, Elbert T, Hoke M, Eiger CE. Possibilities and limitations of magnetic source imaging of methohexital-induced epileptiform patterns in temporal lobe epilepsy patients. Electroenceph Clin Neurophysiol 1997; 102: 423–436
  • Mikuni N, Nagamine T, Ikeda A, Terada K, Taki W, Kimura J, Kikuchi H, Shibasaki H. Simultaneous recording of epileptiform discharges by MEG and subdural electrodes in temporal lobe epilepsy. Neuroimage 1997; 5: 298-306
  • Nakasato N, Levesque MF, Barth DS, Baumgartner C, Rogers RL, Sutherling WW. Comparisons of MEG, EEG, and ECoG source localization in neocortical partial epilepsy in humans. Electro-enceph Clin Neurophysiol 1994; 171: 171–178
  • Sutherling VVVV, Crandall PH, Engel J Jr, Darcey TM, Cahan LD, Barth DS. The magnetic field of complex partial seizures agrees with intracranial localizations. Ann Neurol 1987; 21: 548–558
  • Shimizu H, Suzuki I, Ohta Y, Ishijima B. Mesial temporal subdural electrode as a substitute for depth electrode. Surg Neuro 11992; 38: 186-191
  • Sarvas J. Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem. Phys Med Bio 11987; 32: 11-22
  • Shigeto H, Tobimatsu 5, Morioka T, Yamamoto T, Kobayashi T, Kato M. Jerk-locked back averaging and dipole source localization of magnetoencephalographictransients in a patient with epilepsia partialis continua. Electroenceph Clin Neurophysiol 1997; 103: 440–444
  • Cooper R, Winter AL, Crow Hi, Walter WG. Comparison of subcortica I, cortical and scalp activity using chronically indwelling electrodes in man. Eelectroenceph Clin Neurophysiol 1965; 18: 217–228
  • Ebersole JS. MagnetoencephalographyMagnetic source imaging in the assessment of patients with epilepsy. Epilepsia 1997; 38: S1–5
  • Stefan H, Schtiler P, Abraham-Fuchs K, Schneider 5, Gebhardt M, Neubauer U, Hummel C, Huk WJ, Thierauf P. Magnetic source localization and morphological changes in temporal lobe epilepsy: Comparison of MEG/EEG, ECoG and volumetric MRI in presurgical evaluation of operated patients. Acta Neurol Scand 1994; 152: 83–88
  • Sutherling VVVV, Barth DS. Neocortical propagation in temporal lobe spike foci on magnetoencephalography and electro-encephalography.Ann Neurol 1989; 25: 373–381
  • Hisada K, Morioka T, Nishio 5, Yamamoto T, Fukui M. Two magnetoencephalographicepileptic foci did not coincide with the electrocorticographic ictal onset zone in a patient with temporal lobe epilepsy. Neurol Res 2001; 23: 830–834
  • Wikswo JP, Barach JP, Freeman JA. Magnetic field of the nerve impulse: First measurement. Science 1980; 208: 53–55
  • Ahonen Al, Hämäläinen MS, Ilmoniemi RJ, Kajola MJ, Knuutila JET, Simola JT, Vikman VA. Sampling theory for neuromagnetic detector arrays. IEEE Trans Biomed Eng 1993; 40: 859–869
  • Alarcon G, Guy CN, Binnie CD, Walker SR, Elwes RDC, Polkey CE. Intracerebral propagation of interictal activity in partial epilepsy: Implications for source localisation. I Neurol Neurosurg Psychiatry 1994; 57: 435-449

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.