References
- Iijima M, Muguruma T, Brantley WA, Okayama M, Yuasa T, Mizoguchi I. Torsional properties and microstructures of miniscrew implants. Am J Orthod Dentofacial Orthop 2008; 134: 333.e1–6.
- Miyawaki S, Koyama I, Inoue M, Mishima K, Sugahara T, Tanako-Yamamoto T. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop 2003; 124: 373–78.
- Cheng S, Tseng I, Lee J, Kok S. A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Implants 2004; 19: 100–06.
- Park H, Jeong S, Kwon O. Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthoped 2006; 130: 18–25.
- Wiechmann D, Meyer U, Büchter A. Success rate of mini- and micro-implants used for orthodontic anchorage: a prospective clinical study. Clin Oral Implants Res 2006; 18: 263–67.
- Kuroda S, Sugawara Y, Deguchi T, Kyung H, Tanako-Yamamoto T. Clinical use of miniscrew implants as orthodontic anchorage: success rates and postoperative discomfort. Am J Orthod Dentofacial Orthop 2007; 131: 9–15.
- Chen Y, Kyung HM, WT Zhao, WJ Yu. Critical factors for the success of orthodontic mini-implants: a systematic review. Am J Orthod Dentofacial Orthop 2009; 135: 284–91.
- Schätzle M, R Männchen, M Zwahlen, NP Lang. Survival and failure rates of orthodontic temporary anchorage devices: a systematic review. Clin Oral Implants Res 2009; 20: 1351–59.
- Reynders R, L Ronchi, S Bipat. Mini-implants in orthodontics: a systematic review of the literature. Am J Orthod Dentofacial Orthop 2009; 135: 564.e1–19.
- Kravitz ND, B Kusnoto. Risks and complications of orthodontic miniscrews. Am J Orthod Dentofacial Orthop 2007; 131: S43–51.
- Scholz RP, A Cook. Sterilization requirements for the placement of temporary anchorage devices. Am J Orthod Dentofacial Orthop 2009; 135: S20–22.
- Dorst J. Sterilization requirements for miniscrew placement. Am J Orthod Dentofacial Orthop 2009; 136: 621.
- Boeckler AF, D Morton, C Ehring, JM Setz. Influence of sterilization on the retention properties of magnetic attachments for dental implants. Clin Oral Implants Res 2009; 20: 1206–11.
- Mayhew MJ, RP Kusy. Effects of sterilization on the mechanical properties and the surface topography of nickel–titanium arch wires. Am J Orthod Dentofacial Orthop 1988; 93: 232–36.
- Staggers JA, D Margeson. The effects of sterilization on the tensile strength of orthodontic wires. Angle Orthod 1993; 63: 141–44.
- Lee SH, YI Chang. Effects of recycling on the mechanical properties and the surface topography of nickel–titanium alloy wires. Am J Orthod Dentofacial Orthop 2001; 120: 654–63.
- Pernier C, B Grosgogeat, L Ponsonnet, G Benay, M Lissac. Influence of autoclave sterilization on the surface parameters and mechanical properties of six orthodontic wires. Eur J Orthod 2005; 27: 72–81.
- Schwartz Z, CH Lohmann, G Blau. Re-use of implant coverscrews changes their surface properties but not clinical outcome. Clin Oral Implants Res 2000; 11: 183–94.
- Thierry B, M Tabrizian, O Savadogo, LH Yahia. Effects of sterilization processes on NiTi alloy: surface characterization. J Biomed Mater Res 2000; 49: 88–98.
- Vezeau PJ, GF Koorbusch, RA Draughn, JC Keller. Effects of multiple sterilization on surface characteristics and in vitro biologic responses to titanium. J Oral Maxillofac Surg 1996; 54: 738–46.
- Adelson RT, RJ Defatta, Y Ducic. Integrity of craniofacial plating systems after multiple sterilization procedures. J Oral Maxillofac Surg 2007; 65: 940–44.
- Pithon M, L Nojima, M Nojima, AC Ruellas. Comparative study of fracture torque for orthodontic mini-implants of different trademarks. Oral Surg 2008; 1: 84–87.
- Jolley TH, C Chung. Peak torque values at fracture of orthodontic miniscrews. J Clin Orthod 2007; 41: 326–28.
- Carano A, S Velo, P Leone, G Siciliani. Clinical applications of the miniscrew anchorage system. J Clin Orthod 2005; 39: 9–24.
- Carano A, P Lonardo, S Velo, C Incorvati. Mechanical properties of three different commercially available miniscrews for skeletal anchorage. Prog Orthod 2005; 6: 82–97.
- Lim S-A, J-Y Cha, C-J Hwang. Insertion torque of orthodontic miniscrews according to changes in shape, diameter and length. Angle Orthod 2008; 78: 234–40.
- Motoyoshi M, M Hirabayahi, M Uemura, N Shimizu. Recommended placement torque when tightening an orthodontic mini-implant. Clin Oral Implants Res 2006; 17: 109–14.
- Chen Y, Y Chen, L Lin, CJ Yao. Removal torque of miniscrews used for orthodontic anchorage – a preliminary report. Int J Oral Maxillofac Implants 2006; 21: 283–89.
- Kim S, J Cho, K Chung, Y Kook, G Nelson. Removal torque values of surface-treated mini-implants after loading. Am J Orthod Dentofacial Orthop 2008; 134: 36–43.
- Marquezan M, T Lau, C Rodrigues. Shear bond strengths of orthodontic brackets with a new LED cluster curing light. J Orthod 2010; 37: 37–42.
- Mizrahi E, B Mizrahi. Mini-screw implants (temporary anchorage devices): orthodontic and pre-prosthetic applications. J Orthod 2007; 34: 80–94.