174
Views
12
CrossRef citations to date
0
Altmetric
Research Papers

Treating Ti containing dental orthodontic wires with nitrogen plasma immersion ion implantation to reduce the metal ions release and bacterial adhesion

, &
Pages B73-B79 | Received 27 Nov 2014, Accepted 28 Dec 2014, Published online: 07 Jan 2015

References

  • Li J, Helmerhorst EJ, Leone CW, Troxler RF, Yaskell T, Haffajee AD, Socransky SS and Oppenheim FG: ‘Identification of early microbial colonizers in human dental biofilm’, J. Appl. Microbiol., 2004, 97, 1311–1318.
  • Schmalz G and Garhammer P: ‘Biological interactions of dental cast alloys with oral tissues’, Dent. Mater., 2002, 18, 396–406.
  • Pohrelyuk IM, Fedirko VM, Tkachuk OV and Proskurnyak RV: ‘Corrosion resistance of Ti–6Al–4V alloy with nitride coatings in Ringer’s solution’, Corros. Sci., 2013, 66, 392–398.
  • Liu A, Deng J, Cui H, Chen Y and Zhao J: ‘Friction and wear properties of TiN, TiAlN, AlTiN and CrAlN PVD nitride coatings’, Int. J. Refract. Met. Hard Mater., 2012, 31, 82–88.
  • Bal BS and Rahaman MN: ‘Orthopedic applications of silicon nitride ceramics’, Acta Biomater., 2012, 8, 2889–2898.
  • Kshirsagar A, Nyaupane P, Bodas D, Duttagupta SP and Gangal SA: ‘Deposition and characterization of low temperature silicon nitride films deposited by inductively coupled plasma CVD’, Appl. Surf. Sci., 2011, 257, 5052–5058.
  • Wang J, Zhang L, Zhao G, Gu Y, Zhang Z, Zhang F and Wang W: ‘Selective synthesis of boron nitride nanotubes by self-propagation high-temperature synthesis and annealing process’, J. Solid State Chem., 2011, 184, 2478–2484.
  • Yang CH, Li YC, Tsai WF, Ai CF and Huang HH: ‘Oxygen plasma immersion ion implantation treatment enhances the human bone marrow mesenchymal stem cells responses to titanium surface for dental implant application’, Clin. Oral Implants Res., 2015, 26, 166–175.
  • Huang HH, Huang HM, Lin MC, Zhang W, Sun YS, Kai W and Liaw PK: ‘Enhancing the bio-corrosion resistance of Ni-free ZrCuFeAl bulk metallic glass through nitrogen plasma immersion ion implantation’, J. Alloys Compd., 2014, 615, S660–S665.
  • Huang HH: ‘Surface characterizations and corrosion resistance of nickel–titanium orthodontic archwires in artificial saliva of various degrees of acidity’, J. Biomed. Mater. Res. A, 2005, 74A, 629–639.
  • Schiff N, Grosgogeat B, Lissac M and Dalard F: ‘Influence of fluoridated mouthwashes on corrosion resistance of orthodontics wires’, Biomaterials, 2004, 25, 4535–4542.
  • Al OE: ‘Medical laboratory science: theory and practice’; 2000, New Delhi, Tata McGraw-Hill.
  • Hazan R, Que YA, Maura D and Rahme LG: ‘A method for high throughput determination of viable bacteria cell counts in 96-well plates’, BMC Microbiol., 2012, 12, 259.
  • Hu H, Liu X and Ding C: ‘Preparation and in vitro evaluation of nanostructured TiO2/TCP composite coating by plasma electrolytic oxidation’, J. Alloys Compd., 2010, 498, 172−178.
  • Yang CH, Wang YT, Tsai WF, Ai CF, Lin MC and Huang HH: ‘Effect of oxygen plasma immersion ion implantation treatment on corrosion resistance and cell adhesion of titanium surface’, Clin. Oral Implants Res., 2011, 22, 1426−1436.
  • Antunes RA, de Oliveira MCL and Pillis MF: ‘Effect of the deposition temperature on the corrosion stability of TiO2 films prepared by metal organic chemical vapor deposition’, Int. J. Electrochem. Sci., 2013, 8, 1487−1500.
  • Piscanec S, Ciacchi LC, Vesselli E, Comelli G, Sbaizero O, Meriani S and Vita AD: ‘Bioactivity of TiN-coated titanium implants’, Acta Mater., 2004, 52, 1237–1245.
  • Yeung KWK, Poon RWY, Liu X, Ho JPY, Chung CY, Chu PK, Lu WW, Chan D and Cheung KMC: ‘Nickel suppression in NiTi alloys by plasma immersion ion implantation surface treatment New materials for orthopaedic implantation’, Eur. Cell Mater., 2005, 10, 78.
  • Huang HH, Hsu CH, Pan SJ, He JL, Chen CC and Lee TL: ‘Corrosion and cell adhesion behavior of TiN-coated and ion-nitrided titanium for dental applications’, Appl. Surf. Sci., 2005, 244, 252–256.
  • Zhao Q, Liu Y, Wang C, Wang S, Peng N and Jeynes C: ‘Reduction of bacterial adhesion on ion-implanted stainless steel surfaces’, Med. Eng. Phys., 2008, 30, 341–349.
  • Zerkout S, Achour S, Mosser A and Tabet N: ‘On the existence of superstructure in TiNx thin films’, Thin Solid Films, 2003, 441, 135–139.
  • Scarano A, Piattelli M, Vrespa G, Caputi S and Piattelli A: ‘Bacterial adhesion on titanium nitride-coated and uncoated implants: an in vivo human study’, J. Oral Implantol., 2003, 29, 80–85.
  • Jeyachandran YL, Narayandass SaK, Mangalaraj D, Bao CY and Martin PJ: ‘The effect of surface composition of titanium films on bacterial adhesion’, Biomed. Mater., 2006, 1, L1.
  • Grass G, Rensing C and Solioz M: ‘Metallic copper as an antimicrobial surface’, Appl. Environ. Microbiol., 2011, 77, 1541–1547.
  • Hozumi I, Hasegawa T, Honda A, Ozawa K, Hayashi Y, Hashimoto K, Yamada M, Koumura A, Sakurai T, Kimura A, Tanaka Y, Satoh M and Inuzuka T: ‘Patterns of levels of biological metals in CSF differ among neurodegenerative diseases’, J. Neurol. Sci., 2011, 303, 95–99.
  • Zhang X, Ma Y, Lin N, Huang X, Hang R, Fan A and Tang B: ‘Microstructure, antibacterial properties and wear resistance of plasma Cu–Ni surface modified titanium’, Surf. Coat. Technol., 2013, 232, 515–520.
  • Zhang W, Li Y, Niu J and Chen Y: ‘Photogeneration of reactive oxygen species on uncoated silver, gold, nickel, and silicon nanoparticles and their antibacterial effects’, Langmuir, 2013, 29, 4647–4651.
  • Lee SB, Choi JY, Park WW, Jeon JH, Won SO, Byun JY, Lim SH and Han SH: ‘A study of TiN-coated metal-on-polymer bearing materials for hip prosthesis’, Met. Mater. Int., 2010, 16, 679–686.
  • van Hove RP, Nolte PA, Semeins CM and Klein-Nulend J: ‘Differences in proliferation, differentiation, and cytokine production by bone cells seeded on titanium–nitride and cobalt–chromium–molybdenum surfaces’, J. Biomater. Appl., 2013, 28, 278–287.
  • Huang HH, Hsu CH, Pan SJ, He JL, Chen CC and Lee TL: ‘Corrosion and cell adhesion behavior of TiN-coated and ion-nitrided titanium for dental applications’, Appl. Surf. Sci., 2005, 244, 252–256.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.