Publication Cover
Cochlear Implants International
An Interdisciplinary Journal for Implantable Hearing Devices
Volume 14, 2013 - Issue 3
148
Views
10
CrossRef citations to date
0
Altmetric
How we do it

Effect of total intravenous anaesthesia on intraoperative monitoring of cochlear implant function in paediatric patients

, &
Pages 169-173 | Published online: 15 Nov 2013

References

  • Banoub M., Tetzlaff J.E., Schubert A. 2003. Pharmacologic and physiologic influences affecting sensory evoked potentials: implications for perioperative monitoring. Anesthesiology, 99: 716–737.
  • Bissinger U., Plinkert P.K., Sesterhenn G., Grimm A., Lenz G. 2000. Influence of volatile and intravenous anesthetics on the threshold of the acoustically evoked stapedius reflex. Eur Arch Otorhinolaryngol, 257: 349–354.
  • Borg E. 1973. On neuronal organization of the acoustic middle ear reflex. A physiological and anatomical study. Brain Res, 49: 101–123.
  • Crawford M.W., White M.C., Propst E.J., Zaarour C., Cushing S., Pehora C., et al. 2009. Dose-dependent suppression of the electrically elicited stapedial reflex by general anesthetics in children undergoing cochlear implant surgery. Anesth Analg, 108: 1480–1487.
  • Dilger J.P., Brett R.S., Lesko L.A. 1992. Effects of isoflurane on acetylcholine receptors channels. 1. Single-channel currents. Mol Pharmacol, 41: 127–133.
  • Dilger J.P., Vidal A.M., Mody H.I., Liu Y. 1994. Evidence for direct actions of general anesthetics on an ion channel protein. Anesthesiology, 81: 431–442.
  • Gordon K., Papsin B.C., Harrison R.V. 2004. Programming cochlear implant stimulation levels in infants and children with a combination of objective measures. Int J Audiol, 43: S28–S32.
  • Guven S., Tas A., Adali M.K., Yagiz R., Alagol A., Uzun C., et al. 2006. Influence of anesthetic agents on transient evoked otoacoustic emissions and stapedial reflex thresholds. J Laryngol Otol, 120: 10–15.
  • Kumar A., Bhattacharya A., Makhija N. 2000. Evoked potential monitoring in anesthesia and analgesia. Anesthesia, 55: 225–241.
  • Makhdoum M.J.A., Snik A.F.M., Stollman M.H.P., de Grood P.M.R.M., van den Broek P. 1998. The influence of the concentration of volatile anesthetics on the stapedius reflex determined intraoperatively during cochlear implantation in children. Am J Otol, 19: 598–603.
  • Mason S. 2004. Electrophysiologic and objective monitoring of cochlear implant during surgery: implementation, audit and outcomes. Int J Audiol, 43: S33–S38.
  • Padmaja D., Mantha S. 2002. Monitoring of Neuromuscular junction. Indian J Anaesth, 46(4): 279–288.
  • Schultz A., Berger F.A., Weber B.P., Groven U., Niclaus O., Lullwitz E., et al. 2003. Intraoperative electrically elicited stapedial reflex threshold is related to dosage of hypnotic drugs in general anesthesia. Ann Otol Rhinol Laryngol, 112: 1050–1055.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.