References
- Annop S, Sridang P, Puetpaiboon U and Grasmick A. 2013. Influence of relaxation frequency on membrane fouling control in submerged anaerobic membrane bioreactor (SAnMBR), J. Desalin. Water Treat., 1, 1–9.
- DeSouza NP and Basu OD. 2013. Comparative analysis of physical cleaning operations for fouling control of hollow fiber membranes in drinking water treatment, J. Membr. Sci., 436, 28–35.
- Guo X, Li Q, Hu W, Gao W and Liu D. 2008. Ultrafiltration of dissolved organic matter in surface water by a polyvinylchloride hollow fiber membrane, J. Membr. Sci., 327, 254–263.
- Huang, H., Young, T. and Jacangelo, J. (2009). Novel approach for the analysis of bench-scale, low pressure membrane fouling in water treatment. J. Membr. Sci., 334, 1–8.
- Huck PM, Peldszuz S, Halle C, Ruiz H, Jin X, Van Dyke MI and Amy G. 2011. Pilot scale evaluation of biofiltration as an innovative pre-treatment for ultrafiltration membranes for drinking water treatment, Water Sci. Technol. Water Supply, 11, (1), 23–29.
- Katsoufidou K and Yiantsios KAJ. 2006. A study of ultrafiltration membrane fouling by humic acids and flux recovery by backwashing: experiments and modeling, J. Membr. Sci., (1–2), 40–50.
- Kweon JH and Lawler DF. 2005. Investigation of membrane fouling in ultrafiltration using model organic compounds, Water Sci. Technol.: J. Int. Assoc. Water Pollut. Res., 51, (6–7), 101–106.
- Le Clech P, Jefferson B, Chang IS and Judd SJ. 2003. Critical flux determination by the flux-step method in a submerged membrane bioreactor, J. Membr. Sci., 227, (1–2), 81–93.
- Lu, J., Zhang, Z., Ye, T., Qin, X., Huang, Y., Yang, X., Luo, W., Chen, B., Liu, W. and Liang, Y. 2011. Aging of polyvinylchloride membranes in ultrafiltration of drinking water by chemical cleaning. IEEE Multimedia Technology 2011 International Conference: 3834–3837.
- Mierzwa JC, da Silva MCC, Veras LRV, Subtil EL, Rodrigues R, Li T and Landenberger KR. 2012. Enhancing spiral-wound ultrafiltration performance through operational procedures improvement: a feasible option for the Sao Paula Metropolitan Region, J. Desalin., 307, 68–75.
- Nguyen AH, Tobiason JE and Howe KJ. 2011. Fouling indices for low pressure hollow fiber membrane performance assessment, Water Res., 45, (8), 2627–2637.
- Park C, Kim H, Hong S, Lee S and Choi S.-I. 2007. Evaluation of organic matter fouling potential by membrane fouling index, Water Sci. Technol.: Water Supply, 7, (5–6), 27–33.
- Porcelli N and Judd S. 2010. Chemical cleaning of potable water membranes: a review, Separat. Purif. Technol., 71, (2), 137–143.
- Puspitasari, V., Granville, A., Le Clech, P. and Chen, V. 2010. Cleaning and ageing effect of sodium hypochlorite on polyvinylidene fluoride (PVDF) membrane. Separat. Purif. Technol., 72, (3): 301–308.
- Remize PJ, Guigui C and Cabassud C. 2010. Evaluation of backwash efficiency, definition of remaining fouling and characterisation of its contribution in irreversible fouling: case of drinking water production by air-assisted ultra-filtration, J. Membr. Sci., 355, 104–111.
- Sasaki T, Hanaizumi N, Minegishi S, Henmi M and Shimizu Y. 2008. Characterization of PVDF hollow-fiber membrane foulants on drinking water treatment, Water Supply, 8, (5), 557–563.
- Sim LN, Ye Y, Chen V and Fane AG. 2011. Comparison of MFI-UF constant pressure, MFI-UF constant flux and Crossflow Sampler – Modified Fouling Index Ultrfiltraion (CFS-MFIUF), Water Res., 45, 1639–1650.
- Tian, J., Xu, Y., Chen, Z., Nan, J. and Li, G. 2010. Air bubbling for alleviating membrane fouling of immersed hollow-fiber membrane for ultrafiltration of river water. Desalination 260, 225–230.
- Van der Marel P, Zwijnenburg A, Kemperman A, Wessling M, Temmink H and Van der Meer W. 2009. An improved flux-step method to determine the critical flux and the critical flux for irreversibility in a membrane bioreactor, J. Membr. Sci., 332, (1–2), 24–29.
- Wang P, Wang Z, Wu Z, Zhou Q and Yang D. 2010. Effect of hypochlorite cleaning on the physiochemical characteristics of polyvinylidene fluoride membranes, Chem. Eng. J., 162, 1050–1056.
- Wolff, S. H. and Zydney, A. L. 2004. Effect of bleach on the transport characteristics of polysulfone hemodialyzers. J. Membr. Sci., 243, (1–2): 389–399.
- Ye Y, Chen V and Le-Clech P. 2011. Evolution of fouling deposition and removal on hollow fibre membrane during filtration with periodical backwash, Desalination, 283, 198–205.
- Yigit NO, Civelekoglu G, Harman I, Koseoglu H and Kitis M. 2009. Effects of various backwash scenarios on membrane fouling in membrane bioreactors, Desalination, 237, 346–356.
- Zularism AW, Ahmad A, Sakinah M, Ismail AF and Matsuura T. 2011. Role of natural organic matter (NOM), colloidal particles and solution chemistry on ultrafiltration performance, Separat. Purif. Technol., 78, 189–200.