References
- Akdis M, Martin M, Göbel C, Reul H et al. 2002 . Development and testing of a microdiagonal blood pump. Int J Artif Organs , 25 : 666 .
- Allaire EA, Wood HG, Olsen DB et al. 1999 . Blood Flow in a continuous flow ventricular assist device. Artif Organs , 23 : 769 –73.
- Cabrol C, Gandjbakhch A, Pavie A et al. 1990. Heart transplantation – status in Europe. In: T Akutsu, H Koyanagi (Eds), Artificial Heart 3, Tokyo: Springer-Verlag, pp. 263–67.
- Copeland JG, Smith R, Icenogle T et al. 1989 . Orthotopic total artificial heart as a bridge to transplantation, preliminary results. J Heart Transplant , 8 : 123 –8.
- DeBakey ME. 1997 . Development of a ventricular assist device. Artif Organs , 21 : 1149 –53.
- Dowling RD, Gray LA, Frazier OH et al. 2004 . Initial experience with the AbioCor implantable replacement heart system. J Thoracic Cardiovasc Surg , 127 : 131 –41.
- El-Banayosy A, Arusoglu L, Korfer R et al. 2003 . Preliminary experience with the LionHeart left ventricular assist device in patients with end-stage heart failure. Ann Thoracic Surg , 75 : 1469 –75.
- Gerhart RL, Horvath DJ, Golding LA et al. 2002 . The effects of impact on the CorAide ventricular assist device. ASAIO J , 48 : 449 –52.
- Goebel C, Eilers R, Reul H et al. 2001 . Development of the MEDOS/HIA DeltaStream extracorporeal rotary blood pump. Artif Organs , 25 : 358 –65.
- Griffith BP, Kormos RL, Butler KC et al. 2001 . HeartMate II left ventricular assist system: from concept to first clinical use. Ann Thoracic Surg , 71 : 116 –20.
- Kolff WJ. 1993. Total artificial hearts, LVADs or Nothing? And muscle and air-Powered LVADs, Heart Replacement, New York: Springer, pp. 3–11.
- Myers TJ, Dasse KA, Frazier OH et al. 1994 . Use of a left ventricular assist device in an outpatient setting. ASAIO J , 40 : 471 –5.
- Nojiir C, Kijima T, Maekawa J et al. 2000 . Terumo implantable left ventricular assist system: results of long-term animal study. ASAIO J , 46 : 117 –22.
- Pierce WS. 1992 . The artificial heart: paths, progress and patience. Artif Organs , 16 : 314 –26.
- Portner PM. 1984. In: F Unger, A totally implantable ventricular assist device for end-stage heart disease, Assisted Circulation, Vol. 2, Berlin: Springer-Verlag, pp. 115–41.
- Portner PM. 1993. A totally implantable heart assist system: the Novacor program. In: T Akutsu, H Koyanagi (Eds), Heart Replacement, Tokyo: Springer, pp. 71–80.
- Thierry G Mesana. 2004 . Rotary Blood Pumps for Cardiac Assistance: A ȁMustȁ?. Artif Organs , 28 : 218 –25.
- Watterson PA, Woodard JC, Reizes JA et al. 2000 . VentrAssist hydrodynamically suspended, open, centrifugal blood pump. Artif Organs , 24 : 475 –7.
- Westaby S, Frazier OH, Jarvik RK et al. 2002 . Implant technique for the Jarvik 2000 Heart. Ann Thoracic Surg , 73 : 1337 –40.