26
Views
10
CrossRef citations to date
0
Altmetric
Review

Transcatheter closure of patent ductus arteriosus

Pages 865-874 | Published online: 10 Jan 2014

References

  • Campbell M. Natural history of persistent ductus arteriosus. Br. Heart J. 30, 4–13 (1968).
  • Marquis RM, Miller HC, McCormack RJM et al. Persistence of ductus arteriosus with left to right shunt in the older patient. Br. Heart J. 48, 469–484 (1982).
  • Schroeder R, Kadel C. Persistent ductus arteriosus: Is closure indicated also in asymptomatic adults with small ductus and minor shunt? Z. Kardiol. 82, 563–567 (1993).
  • Thilen U, Astrom-Olsson K. Does the risk of infective endarteritis justify routine patent ductus arteriosus closure? Eur. Heart J. 18, 503–506 (1997).
  • Sadiq M, Latif F, Rehman A. Analysis of infective endarteritis in patent ductus arteriosus. Am. J. Cardiol. 93, 513–515 (2004).
  • Wright JS, Newman DC. Ligation of the patent ductus: Technical consideration at different ages. J. Thorac. Cardiovasc. Surg. 75, 695–698 (1978).
  • LeBlanc JG, Russell JL, Sett SS, Potts JE, Human DG, Culham JA. The evolution of ductus arteriosus treatment. Int. Surg. 85, 1–5 (2000).
  • Mavroudis C, Backer CL, Gevitz M. Fortysix years of patent ductus arteriosus division at Childrens Hospital of Chicago: Standards for comparison. Ann. Surg. 1220, 402–409 (1994).
  • Hines MH, Raines KH, Payne RM et al. Videoassisted ductal ligation in premature infants. Ann. Thorac. Surg. 76, 1417–1420 (2003).
  • Bret EL, Papadatos S, Folliquet T et al. Interruption of patent ductus arteriosus in children: Robotically assisted versus videothoracoscopic surgery. J. Thorac. Cardiovasc. Surg. 123, 973–976 (2002).
  • Pass RH, Hijazi ZM, Hsu DT, Lewis V, Hellenbrand WE. Multicenter USA Amplatzer patent ductus arteriosus occlusion device trial. J. Am. Coll. Cardiol. 44, 513–519 (2004).
  • Arora R. Transcatheter devices for large patent ductus arteriosus. Cardiology Today 8, 121–123 (2004).
  • Leon-Wyss J, Vida VL, Veras O et al. Modified extrapleural ligation of PDA: A convenient surgical approach in a developing country. Ann. Thorac. Surg. 79, 632–635 (2005).
  • Porstmann W, Wierny L, Warneke H. Closure of a persistent ductus arteriosus without thoracotomy. Ger. Med. Mon.12, 259–261 (1967).
  • Wierney L, Plass R, Porstmann W. Transluminal closure of patent ductus arteriosus: Long term results of 208 cases treated without thorocatomy. Cardiovasc. Intervent. Radiol. 9, 279–285 (1986).
  • Rashkind WJ. Transcatheter treatment of congenital heart disease. Circulation 67, 711–716 (1986).
  • Hosking MC, Benson LN, Musewe N, Dyck JD, Freedom RM. Transcatheter occlusion of the persistent patent ductus arteriosus. Forty month follow up and prevalence of residual shunting. Circulation 84, 2313–2317 (1991).
  • Khan MA, Al Yousef S, Mullins CE, Sawyer W. Experience with 205 procedures of transcatheter closure of ductus arteriosus in 182 patients, with special reference to residual shunts and long-term follow-up. J. Thorac. Cardiovasc. Surg. 104, 1721–1727 (1992).
  • Arora R, Kalra GS, Nigam M, Khalilullah M. Transcatheter occlusion of patent ductus arteriosus by Rashkind umbrella device: Follow up results. Am. Heart J. 128, 539–541 (1994).
  • Bridges ND, Perry SB, Parness I, Keane JF, Lock JE. Transcatheter closure of a large patent ductus arteriosus with the clamshell septal umbrella. J. Am. Coll. Cardiol. 18, 1297–1302 (1991).
  • Rao PS, Wilson AD, Sideris EB, Chopra PS. Transcatheter closure of patent ductus arteriosus with buttoned device: First successful clinical application in a child. Am. Heart J. 121, 1799–1802 (1991).
  • Rao PS, Kim SH, Choi JY et al. Follow up results of transvenous occlusion of patent ductus arteriosus with the buttoned device. J. Am. Coll. Cardiol. 33, 820–826 (1999).
  • Sideris EB, Rao PS, Zamora R. The Sideris buttoned devices for transcatheter closure of patent ductus arteriosus. J. Interven. Cardiol. 14, 239–246 (2001).
  • Wilson NJ, Occleshaw CJ, O Donnel CP et al. Subclinical aortic perforation with infant double button patent ductus arteriosus occluder. Cathet. Cardiovasc. Intervent. 48, 296–298 (1999).
  • Cambier PA, Kirby WC, Moore JW et al. Percutaneous closure of small (<2.5mm) patent ductus arteriosus using coil embolisation. J. Am. Coll. Cardiol. 9, 815–816 (1992).
  • Moore JW, George L, Kirkpatrick SE et al. Percutaneous closure of small patent ductus arteriosus using occluding spring coils. J. Am. Coll. Cardiol. 23, 759–765 (1994).
  • Berdjis F, Moore JW. Balloon occlusion delivery technique of closure of patent ductus arteriosus. Am. Heart J. 133, 601–604 (1997).
  • Hays MD, Hoyer MH, Glasow PF. New forceps delivery technique for coil occlusion of patent ductus arteriosus. Am. J. Cardiol. 77, 209–211 (1996).
  • Ing FF, Sommer RJ. The snare assisted technique for transcatheter coil occlusion of moderate to large patent ductus arteriosus: immediate and intermediate results. J. Am. Coll. Cardiol. 33, 1710–1718 (1999).
  • Grifka RG, Miller MW, Frischmeyer KJ et al. Transcatheter occlusion of patent ductus arteriosus in a Newfoundland puppy using the Gianturco-Grifka vascular occlusion device. J. Vet. Intern. Med. 10, 42–44 (1996).
  • Le TP, Freudenthal F, Hofstetter R. Transcatheter occlusion of PDA using detachable nitinol coil (Abstract). In: The Fourth Paediatric Interventional Cardiac Symposium. IL, USA, September 24–27 (2000).
  • Kumar RK, Krishnan MN, Venugopal K, Sivakumar K, Anil SR. Bioptome assisted simultaneous delivery of multiple coils for occlusion of the large patent ductus arteriosus. Cathet. Cardiovasc. Intervent. 54, 95–100 (2001).
  • Kumar RK, Anil SR, Kannan BRJ, Philip A, Sivakumar K. Bioptome assisted coil occlusion of moderate-large patent arterial ducts in infants and small children. Cathet. Cardiovasc. Intervent. 62, 266–271 (2004).
  • Krichenko A, Benson L, Burrows P et al. Angiographic classification of the isolated persistently patent ductus arteriosus and implications for percutaneous catheter occlusion. Am. J. Cardiol. 63, 887–889 (1989).
  • Masura J, Walsh KP, Thanopoulos BD et al. Closure of moderate to large sized patent ductus arteriosus using the new Amplatzer duct occluder: Immediate and short term results. J. Am. Coll. Cardiol. 31, 878–882 (1998).
  • Ewert P, Kretschmar O, Neumnberg JH, Nagdyman, Lange PE. First closure of a large patent ductus arteriosus in an infant with an angulated nitinol plug. Cathet. Cardiovasc. Intervent.57, 88–91 (2002).
  • Rao PS. Transcatheter occlusion of patent ductus arteriosus: which method to use and which ductus to close. Am. Heart J. 132, 905–909 (1996).
  • Houston AB, Gnanaprakasam JP, Lim MK, Doig WB, Coloman EN. Doppler ultrasound and the silent ductus. Br. Heart J. 65, 97–99 (1991).
  • Balzer DT, Spray TL, McMullin D, Cottingham W, Cater CE. Endartiritis associated with a clinically silent patent ductus arteriosus. Am. Heart J. 125, 1192–1193 (1993).
  • Lloyd TR, Beekam RH III. Clinically silent patent ductus arteriosus (letter). Am. Heart J. 127, 1664 (1994).
  • Bennhagen RG, Benson LN. Silent and Audible persistent ductus arteriosus. An angiographic study. Pediatr. Cardiol. 24, 27–30 (2003).
  • Wang JK, Liau CS, Huang JJ, Hsu KL et al. Transcatheter closure of patent ductus arteriosus using Gianturco coils in adolescents and adults. Cathet. Cardiovasc. Intervent. 55, 513–518 (2002).
  • Hijazi ZM, Geggel RL. Results of antegrade transcatheter closure of patent ductus arteriosus using single or multiple Gianturco coils. Am. J. Cardiol. 74, 925–929 (1994).
  • Galal MO, Bulbul Z, Kakadekar A et al. Comparison between the safety profile and clinical results of the Cook detachable and Gianturco coils for transcatheter closure of patent ductus arteriosus in 272 patients. J. Interven. Cardiol. 14, 169–171 (2001).
  • Ebeid MR, Gaymes CH, Smith JC et al. Gianturco Grifka vascular occlusion device for closure of patent ductus arteriosus. Am. J. Cardiol. 87, 657–660 (2001).
  • Moore JH, Schneider DJ, Dimeglio D. The duct occlud device: Design, clinical results and future directions. J. Interven. Cardiol. 14, 231–238 (2001).
  • Faella HJ, Hijazi ZM. Closure of the patent ductus arteriosus with the Amplatzer PDA device: immediate results of the international clinical trial. Cathet. Cardiovasc. Intervent. 51, 50–54 (2000).
  • Pedra CA, Sanches SA, Fontes VF. Percutaneous occlusion of the patent ductus arteriosus with the Amplatzer device for atrial septal defects. J. Invas. Cardiol. 15, 413–417 (2003).
  • Hijazi ZM, Ahmad WH, Geggel RL, Marx GR. Intravascular ultrasound during transcatheter coil closure of patent ductus arteriosus: comparison with angiography. J. Invas. Cardiol. 10, 251–254 (1998).
  • Duke C, Chan KC. Aortic obstruction caused by device occlusion of patent arterial duct. Heart 82, 109–111 (1999).
  • Fischer G, Uebing A, Grabitz R, Kramer HH. Transcatheter closure of persistent ductus arteriosus in infants using the Amplatzer duct occluder. Heart 86, 444–447 (2001).
  • Thanopoulos BD, Tsaousis GS, Papadopoulos GS, Eleftherakis N, Zarayelyan AG. Transcatheter closure of patent ductus arteriosus using the swivel disk and the plug occluders. Initial clinical application in children. AGA Medical Fourth International Symposium & Meeting of the European Association for Paediatric Cardiology. 26 (Abstract), 26–27 (2002).
  • Francis E, Anil SR, Sivakumar K, Kumar RK. Trial balloon occlusion for large patent ductus arteriosus with elevated pulmonary vascular resistance. Ind. Heart J. 54–e57, 499 (2002).
  • Thanopoulos BD, Tsaousis GS, Djukic M et al. Transcatheter closure of high pulmonary artery pressure persistent ductus arteriosus with the Amplatzer muscular ventricular septal occluder. Heart 87, 260–263 (2002).
  • John S, Muralidharan S, Mani GK et al. The adult ductus: Review of surgical experience with 131 patients. J. Thorac. Cardiovasc. Surg. 82, 314–319 (1981).
  • Arora R, Singh S, Kalra GS. Patent ductus arteriosus: Catheter closure in the adult patient. J. Interven. Cardiol. 14, 155–159 (2001).
  • Rogues F, Hennequin JL, Sanchez B, Ridarch A, Rousseau H. Aortic stent graft for patent ductus arteriosus in adults: The aortic exclusion technique. Ann. Thorac. Surg. 71, 1708–1709 (2001).
  • Hakim F, Hawelleh AA, Goussous Y, Hijazi ZM. Simultaneous stent implantation for coarctation of the aorta and closure of patent ductus arteriosus using the Amplatzer duct occluder. Cathet. Cardiovasc. Intervent. 47, 36–38 (1999).
  • Sadiq M, Malick NH, Qureshi SA. Simultaneous treatment of native coarctation of the aorta combined with patent ductus arteriosus using a covered stent. Cathet. Cardiovasc. Intervent. 59, 387–390 (2003).
  • Alter BP, Czapek EE, Rowe RD. Sweating in congenital heart disease. Pediatrics 41, 123–129 (1968).
  • Gould DS, Montenegro ZM, Gaynor W et al. A comparison of onsite and offsite patent ductus arteriosus ligation in premature infants. Pediatrics 112, 1298–1301 (2003).
  • Kannan BRJ, Anil SR, Padhi S, Kumar RK. Transcatheter management of patent ductus arteriosus in sick ventilated small infants. Ind. Heart J. 56, 232–234 (2004).
  • Marasini M, Rimini A, Zannini L, Pongiglione G. Giant aneurysm following coil occlusion of patent ductus arteriosus. Cathet. Cardiovasc. Intervent. 50, 186–189 (2000).
  • Wilson WR, Giuliani ER, Danielson GK et al. Symposium on infective endocarditis. II. General considerations in the diagnosis and treatment of infective endocarditis. Mayo Clin. Proc. 57, 81 (1982).
  • Daniels CJ, Cassidy SC, Teske DW et al. Reopening after successful coil occlusion for patent ductus arteriosus. J. Am. Coll. Cardiol. 31, 444–450 (1998).
  • Ebeid MR, Masura J, Hijazi ZM. Early experience with the Amplatzer ductal occluder for closure of the persistently patent ductus arteriosus. J. Interv. Cardiol. 14, 33–36 (2001).
  • Joseph G, Mandalay A, Zacharias TU, George B. Severe intra-vascular haemolysis after transcatheter closure of a large patent ductus arteriosus using the Amplatzer duct occluder:successful resolution by intradevice coil deployment. Cathet. Cardiovasc. Intervent. 55, 245–249 (2002).
  • Wang LH, Wang JK, Mullins CE. Eradication acute hemolysis following transcatheter closure of ductus arteriosus by immediate deployment of a second device. Cathet. Cardiovasc. Diagn. 43, 295–297 (1998).
  • Grifka RG. Transcatheter closure of the patent ductus arteriosus. Cathet. Cardiovasc. Intervent. 61, 554–570 (2004).
  • Jacobs JP, Giroud JM, Quintessenza JA et al. The modern approach to patent ductus arteriosus treatment: Complementary roles of video-assisted thoracoscopic surgery and interventional cardiology coil occlusion. Ann. Thorac. Surg. 76, 1421–1428 (2003).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.