References
- American Diabetes Association. Standards of medical care in diabetes – 2013. Diabetes Care 2013;36(Suppl 1):S11-65
- Boyd JC, Bruns DE. Quality specifications for glucose meters: assessment by simulation modeling of errors in insulin dose. Clin Chem 2001;47:209-14
- Raine CH, Schrock LE, Edelman SV, et al. Significant insulin dose errors may occur if blood glucose results are obtained from miscoded meters. J Diabetes Sci Technol 2007;2:205-10
- Klonoff DC. The need for separate performance goals for glucose sensors in the hypoglycemic, normoglycemic,and hyperglycemic ranges. Diabetes Care 2004;27(3):834-6
- Klonoff DC. Benefits and limitations of self-monitoring of blood glucose. J Diabetes Sci Technol 2007;1:130-2
- Ginsberg BH. Factors affecting blood glucose monitoring: sources of errors in measurement. J Diabetes Sci Technol 2009;3:903-13
- Klonoff DC. Regulatory controversies surround blood glucose monitoring devices. J Diabetes Sci Technol 2010;4:231-5
- Hodges AM, Chatelier RC. Improved glucose measurements using a thin layer cell and tri-pulse electrochemical detection. Clin Chem 2008;54:1934
- In vitro diagnostic test systems – requirements for blood glucose monitoring systems for self-testing in managing diabetes mellitus. ISO15197:2013
- International Organization for Standardization: ISO15197:2003(E). In vitro diagnostic test systems – requirements for blood glucose monitoring systems for self-testing in managing diabetes mellitus. International Organization for Standardization; Geneva: 2003
- Tsujimura S, Kojima S, Kano K, et al. Novel FAD-dependent glucose dehydrogenase for a dioxygen-insensitive glucose biosensor. Biosci Biotechnol Biochem 2006;70:654-9
- Teodorczyk M, Cardosi M, Setford S. Hematocrit compensation in electrochemical blood glucose monitoring systems. J Diabetes Sci Technol 2012;6:648-55
- Pfützner A, Mitri M, Musholt PB, et al. Clinical assessment of the accuracy of blood glucose measurement devices. Curr Med Res Opin 2012;28:525-31
- Parkes JL, Slatin SL, Pardo S, Ginsberg BH. A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. Diabetes Care 2000;23:1143-8
- Pfützner A, Klonoff DC, Pardo S, Parkes JL. Technical aspects of the Parkes error grid. J Diabetes Sci Technol 2013;7:1275-81
- Klonoff DC, Reyes JS. Do currently available blood glucose monitors meet regulatory standards? 1-day public meeting in Arlington, Virginia. J Diabetes Sci Technol 2013;7(4):1071-83
- Craig RM, Murphy P, Gibson TP, et al. Kinetic analysis of D-xylose absorption in normal subjects and in patients with chronic renal failure. J Lab Clin Med 1983;101:496-506
- Musholt PB, Schipper C, Thomé N, et al. Dynamic electrochemistry corrects for hematocrit interference on blood glucose determinations with patient self-measurement devices. J Diabetes Sci Technol 2011;5(5):1167-75
- Ramljak S, Lock JP, Schipper C, et al. Hematocrit interference of blood glucose meters for patient self-measurement. J Diabetes Sci Technol 2013;7:179-89
- Pfützner A, Schipper C, Ramljak S, et al. Determination of hematocrit interference in blood samples derived from patients with different blood glucose concentrations. J Diabetes Sci Technol 2013;7:170-8