610
Views
20
CrossRef citations to date
0
Altmetric
Review

Technology platforms for remote monitoring of vital signs in the new era of telemedicine

, &

References

  • Kalorama Information. Remote and wireless patient monitoring markets 2012
  • Frost & Sullivan. European remote patient monitoring markets 2007
  • Frost & Sullivan. European remote patient monitoring market 2010
  • Frost & Sullivan. Emerging telehealth markets present compelling opportunities in Asia-Pacific 2010. Available from: http://www.frost.com/prod/servlet/press-release.pag?docid=278390753 [Last accessed on 27 May 2015]
  • Teng XF, Zhang YT, Poon CCY, Bonato P. Wearable medical systems for p-Health. IEEE Rev Biomed Eng 2008;1:62-74
  • Topol EJ. Transforming medicine via digital innovation. Sci Transl Med 2010;2(16):1-3
  • Scanaill C, Carew S, Barralon P, et al. A review of approaches to mobility telemonitoring of the elderly in their living environment. Ann Biomed Eng 2006;4(4):547-63
  • Baig MM, Gholamhosseini H, Connolly MJ. A comprehensive survey of wearable and wireless ECG monitoring systems for older adults. Med Biol Eng Comput 2013;51(5):485-95
  • Allet L, Knols RH, Shirato K, de Bruin ED. Wearable systems for monitoring mobility-related activities in chronic disease: a systematic review. Sensors (Basel) 2010;10(10):9026-52
  • Patel S, Park H, Bonato P, et al. A review of wearable Sensors (Basel) and systems with application in rehabilitation. J Neuroeng Rehabil 2012;9:21
  • Jencks SF, Williams MV, Coleman EA. Rehospitalizations among patients in the Medicare fee-for-service program. N Engl J Med 2009;360(14):1418-28
  • Bolton CE, Waters CS, Peirce S, Elwyn G; EPSRC and MRC Grand Challenge Team. Insufficient evidence of benefit: a systematic review of home telemonitoring for COPD. J Eval Clin Pract 2011;17(6):1216-22
  • Tunstal Healthcare. Sheffield NHS primary care trust telehealth case study. 2009
  • Perry AC, Galanos AN. Home automated external defibrillators in a geriatric population: a brief discussion of the evidence. J Am Geriatr Soc 2006;54(1):133-7
  • Bardy GH, Lee KL, Mark DB, et al. Home use of automated external defibrillators for sudden cardiac arrest. N Engl J Med 2008;358(17):1793-804
  • Klersy C, De Silvestri A, Gabutti G, et al. A meta-analysis of remote monitoring of heart failure patients. J Am Coll Cardiol 2009;54(18):1683-94
  • Inglis SC, Clark RA, McAlister FA, et al. Structured telephone support or telemonitoring programmes for patients with chronic heart failure. Cochrane Database Syst Rev 2010;8:CD007228
  • Steventon A, Bardsley M, Billings J, et al. Effect of telehealth on use of secondary care and mortality: findings from the Whole System Demonstrator cluster randomised trial. BMJ 2012;344:e3874
  • Edelman SV, Bailey TS. Continuous glucose monitoring health outcomes. Diabetes Technol Ther 2009;11(s1):S68-74
  • Poh MZ, Swenson N, Picard R. A wearable sensor for unobtrusive, long-term assessment of electrodermal activity. IEEE Trans Biomed Eng 2010;57(5):1243-52
  • Lobodzinski SS. ECG patch monitors for assessment of cardiac rhythm abnormalities. Prog Cardiovasc Dis 2013;56(2):224-9
  • Di Rienzo M, Rizzo F, Parati G, et al. MagIC system: a new textile-based wearable device for biological signal monitoring applicability in daily life and clinical setting. Conf Proc IEEE Eng Med Biol Soc 2005;7:7167-9
  • Lee YD, Chung WY. Wireless sensor network based wearable smart shirt for ubiquitous health and activity monitoring. Sensor Actuat. B Chem 2009;140(2):390-5
  • Wearable tech. Available from: www.pinterest.com/caroltpin/wearable-tech/[Last accessed on 25 April 2014]
  • Scalise L. Non contact heart monitoring, advances in electrocardiograms - methods and analysis. PhD Richard M, Ed.), ISBN: 978-953-307-923-3, InTech; DOI: 10.5772/22937. 81-106 2012. Available from: www.intechopen.com/books/advances-in-electrocardiograms-methods-and-analysis/non-contact-heart-monitoring [Last accessed on 25 April 2014]
  • Jovanov E, Milenkovic A. Body area networks for ubiquitous healthcare applications: opportunities and challenges. J Med Syst 2011;35(5):1245-54
  • Darwish A, Hassanien AE. Wearable and implantable wireless sensor network solutions for healthcare monitoring. Sensor 2011;11(6):5561-95
  • Custodio V, Herrera FJ, López G, Moreno JI. A review on architectures and communications technologies for wearable health-monitoring systems. Sensors (Basel) 2012;12(10):13907-46
  • Zhang GH, Poon CCY, Li Y, Zhang YT. A biometric method to secure telemedicine systems. In Proceedings of the 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society; Minneapolis, MN, USA, September 2009. 701-4
  • Bao S, Zhang Y, Shen L. Physiological signal based entity authentication for body area sensor networks and mobile healthcare systems. In Proceedings of the 27th Annual International Conference of the IEEE EMBS; Shanghai, China, 1–4 September 2005. pp. 2455-8
  • Liu A, Ning P, TinyECC A. Configurable Library for Elliptic Curve Cryptography in Wireless Sensor Networks. In Proceedings of the 7th International Conference on Information Processing in Sensor Networks; St. Louis, MO, USA, 22–24 April 2008. 245-56
  • Karlof C, Sastry N, Wagner D. TinySec A Link Layer Security Architecture for Wireless Sensor Networks. In Proceedings of the 2nd International Conference on Embedded Networked Sensor Systems; Baltimore, MD, USA, 3–5 November 2004. 162-75
  • Tsukada S, Nakashima H, Torimitsu K. Conductive polymer combined silk fiber bundle for bioelectrical signal recording. PLoS One 2012;7(4):e33689
  • Rosenberg MA, Samuel M, Thosani A, Zimetbaum PJ. Use of a noninvasive continuous monitoring device in the management of atrial fibrillation: a pilot study. Pacing Clin Electrophysiol 2013;36(3):328-33
  • Turakhia MP, Hoang DD, Zimetbaum P, et al. Diagnostic utility of a novel leadless arrhythmia monitoring device. Am J Cardiol 2013;112(4):520-4
  • Barrett PM, Komatireddy R, Haaser S, et al. Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring. Am J Med 2014;127(1):95.e11-17
  • Engel JM, Chakravarthy N, Katra RP, et al. Estimation of patient compliance in application of adherent mobile cardiac telemetry device. Conf Proc IEEE Eng Med Biol Soc 2011;2011:1536-9
  • Suzuki S, Matsui T, Sugawara K, et al. An approach to remote monitoring of heart rate variability (HRV) using microwave radar during a calculation task. Am J Phys Anthropol 2011;30(6):241-9
  • Lu G, Yang F, Tian Y, et al. Contact-free measurement of heart rate variability via a microwave sensor. Sensors (Basel) 2009;9(12):9572-81
  • Kim CY, Hong S. A compact 24 GHz quadrature Doppler radar with front-end MMIC. Int J Electron 2013;100(9):1184-95
  • Kao TYJ, Chen AYK, Yan Y, et al. A flip-chip-packaged and fully integrated 60 GHz CMOS micro-radar sensor for heartbeat and mechanical vibration detections. IEEE Rad Freq Integr 2012;2012:17-19
  • Thiel F, Kreiseler D, Seifert F. Non-contact detection of myocardium’s mechanical activity by ultrawideband RF-radar and interpretation applying electrocardiography. Rev Sci Instrum 2009;80(11):114302
  • Margaret D, Anith S, Duraisamy M, Muneeswaran K. Cross slot antenna with open ended truncated patch feed for ultra wide band applications. IEEE INCACEC 2009;1-6
  • Li C, Lin J. Complex signal demodulation and random body movement cancellation techniques for non-contact vital sign detection. IEEE Mtt S 2008;567-70
  • Sensiotec Inc. Virtual Medical Assistant. Available from: http://sensiotec.com/virtual-medical-assistant/ [Last accessed on 25 April 2014]
  • Takano C, Ohta Y. Heart rate measurement based on a time-lapse image. Med Eng Phys 2007;29(8):853-7
  • Verkruysse W, Svaasand LO, Nelson JS. Remote plethysmographic imaging using ambient light. Opt Express 2008;16(26):21434-45
  • Poh MZ, McDuff DJ, Picard RW. Non-contact, automated cardiac pulse measurements using video imaging and blind source separation. Opt Express 2010;18(10):10762-74
  • Poh MZ, McDuff DJ, Picard RW. Advancements in noncontact, multiparameter physiological measurements using a webcam. IEEE Trans Biomed Eng 2011;58(1):7-11
  • Zhao F, Li M, Qian Y, Tsien JZ. Remote measurements of heart and respiration rates for telemedicine. PLoS One 2013;8(10):e71384
  • Aarts LA, Jeanne V, Cleary JP, et al. Non-contact heart rate monitoring utilizing camera photoplethysmography in the neonatal intensive care unit – a pilot study. Early Hum Dev 2013;89(12):943-8
  • Villarroel M, Guazzi A, Jorge J, et al. Continuous non-contact vital sign monitoring in neonatal intensive care unit. Healthcare Technol Lett 2014;1(3):87-91
  • Scalise L, Morbiducci U. Non-contact cardiac monitoring from carotid artery using optical vibrocardiography. Med Eng Phys 2008;30(4):490-7
  • Morbiducci U, Scalise L, De Melis M, Grigioni M. Optical vibrocardiography: a novel tool for the optical monitoring of cardiac activity. Ann Biomed Eng 2007;35(1):45-58
  • De Melis M, Morbiducci U, Scalise L, et al. A non contact approach for the evaluation of large artery stiffness: a preliminary study. Am J Hyp 2008;21(12):1280-3
  • Teichmann D, Foussier J, Jia J, et al. Noncontact monitoring of cardiorespiratory activity by electromagnetic coupling. IEEE Trans Biomed Eng 2013;60(8):2142-52
  • Garbey M, Sun N, Merla A, Pavlidis I. Contact-free measurement of cardiac pulse based on the analysis of thermal imagery. IEEE Trans Biomed Eng 2007;54(8):1418-26
  • Jeong JW, Jang YW, Lee I, et al. Wearable respiratory rate monitoring using Piezo-resistive fabric sensor. In: Magjarevic R, Nagel JH, D¨ossel O, Schlegel WC, Editors World Congress on Medical Physics and Biomedical Engineering. Springer, Berlin/Heidelberg, Germany 2009; p. 282-4
  • Karki S, Lekkala J. Film-type transducer materials PVDF and EMFi in the measurement of heart and respiration rates. Conf Proc IEEE Eng Med Biol Soc 2008;2008:530-3
  • Zito D, Pepe D, Mincica M, et al. Wearable system-on-a-chip UWB radar for contact-less cardiopulmonary monitoring: present status. Conf Proc IEEE Eng Med Biol Soc 2008;2008:5274-7
  • Baboli M, Boric-Lubecke O, Lubecke V. A new algorithm for detection of heart and respiration rate with UWB signals. Conf Proc IEEE Eng Med Biol Soc 2012;2012:3947-50
  • Tan KS, Saatchi R, Elphick H, Burke D. Real-time vision based respiration monitoring system. IEEE CSNDSP 2010;770-4
  • Abbas AK, Heimann K, Jergus K, et al. Neonatal non-contact respiratory monitoring based on real-time infrared thermography. Biomed Eng Online 2011;10:93
  • Alpert BS. Oscillometric blood pressure values are algorithm specific. Am J Cardiol 2010;106(10):1524-5
  • Edwards Lifesciences Corporation. ccNexfin System. Available from: www.edwards.com/products/mininvasive/pages/ccnexfinsystem.aspx [Last accessed on 25 April 2014]
  • CNSystems Medizintechnik AG. CNAP® Monitor 500. Available from: www.cnsystems.at/products/cnap-monitor-500 [Last accessed on 25 April 2014]
  • Tensys Medical, Inc. TL-300. Available from: http://tensysmedical.com/us/products/ [Last accessed on 25 April 2014]
  • Sotera Wireless, Inc. Visi Mobile. Available from: www.visimobile.com/[Last accessed on 25 April 2014)
  • Eeftinck Schattenkerk DW, van Lieshout JJ, van den Meiracker AH, et al. Nexfin noninvasive continuous blood pressure validated against Riva-Rocci/Korotkoff. Am J Hypertens 2009;22(4):378-83
  • Garnier RP, van der Spoel AG, Sibarani-Ponsen R, et al. Level of agreement between Nexfin non-invasive arterial pressure with invasive arterial pressure measurements in children. Br J Anaesth 2012;109(4):609-15
  • Fischer MO, Avram R, Cârjaliu I, et al. Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery. Br J Anaesth 2012;109(4):514-21
  • McCarthy T, Telec N, Dennis A, et al. Ability of non- invasive intermittent blood pressure monitoring and a continuous non-invasive arterial pressure monitor (CNAP™) to provide new readings in each 1-min interval during elective caesarean section under spinal anaesthesia. Anaesthesia 2012;67(3):274-9
  • Saugel B, Fassio F, Hapfelmeier A, et al.200 system for continuous non- invasive blood pressure measurement in medical intensive care unit patients. Intensive Care Med 2012;38(9):1471-2
  • Saugel B, Meidert AS, Hapfelmeier A, et al. Non- invasive continuous arterial pressure measurement based on radial artery tonometry in the intensive care unit: a method comparison study using the T- Line TL-200pro device. Br J Anaesth 2013;111(2):185-90
  • Medtronic Inc. mySentryTM Remote Glucose Monitor. Available from: www.medtronicdiabetes.net/treatment-and-products/mysentry-remote-glucose-monitor [Last accessed on 25 April 2014]
  • Leboulanger B, Guy RH, Delgado-Charro M. Reverse iontophoresis for non-invasive transdermal monitoring. Physiol Meas 2004;25(3):R35-50
  • Tao D, Adler A. In vivo blood characterization from bioimpedance spectroscopy of blood pooling. IEEE Trans Instrum Meas 2009;58(11):3831-8
  • Caduff A, Talary MS, Mueller M, et al. Non-invasive glucose monitoring in patients with Type 1 diabetes: a multisensor system combining Sensors (Basel) for dielectric and optical characterisation of skin. Biosens Bioelectron 2009;24(9):2778-84
  • Tura A, Sbrignadello S, Cianciavicchia D, et al. A low frequency electromagnetic sensor for indirect measurement of glucose concentration: in vitro experiments in different conductive solutions. Sensors (Basel) 2010;10(6):5346-58
  • Melikyan H, Danielyan E, Kim SW, et al. Non-invasive in vitro sensing of D-glucose in pig blood. Med Eng Phys 2012;34(3):299-304
  • Arnold MA, Small GW. Noninvasive glucose sensing. Anal Chem 2005;77(17):5429-39
  • Vonlilienfeldtoal H, Weidenmuller M, Xhelaj A, Mantele W. A novel approach to non- invasive glucose measurement by mid-infrared spectroscopy: the combination of quantum cascade lasers (QCL) and photoacoustic detection. Vib Spectrosc 2005;38(1-2):209-15
  • Ellis DI, Goodacre R. Metabolic fingerprinting in disease diagnosis: biomedical applications of infrared and Raman spectroscopy. Analyst 2006;131(8):875-85
  • Larin KV, Eledrisi MS, Motamedi M, Esenaliev RO. Noninvasive blood glucose monitoring with optical coherence tomography: a pilot study in human subjects. Diabetes Care 2002;25(12):2263-7
  • Malik BH, Cote GL. Real-time, closed-loop dual-wavelength optical polarimetry for glucose monitoring. J Biomed Opt 2010;15(1):017002
  • Lee S, Nayak V, Dodds J, et al. Glucose measurements with sensors and ultrasound. Ultrasound Med Biol 2005;31(7):971-7
  • March WF, Mueller A, Herbrechtsmeier P. Clinical trial of a noninvasive contact lens glucose sensor. Diabetes Technol Ther 2004;6(6):782-9
  • Alexeev VL, Das S, Finegold DN, Asher SA. Photonic crystal glucose-sensing material for noninvasive monitoring of glucose in tear fluid. Clin Chem 2004;50(12):2353-60
  • Yao H, Shum AJ, Cowan M, et al. A contact lens with embedded sensor for monitoring tear glucose level. Biosens Bioelectron 2011;26(7):3290-6
  • Patel JN, Gray BL, Kaminska B, Gates BD. Flexible three-dimensional electrochemical glucose sensor with improved sensitivity realized in hybrid polymer microelectromechanical systems technique. J Diabetes Sci Technol 2011;5(5):1036-43
  • Liao YT, Yao H, Lingley A, et al. 3-µW CMOS glucose sensor for wireless contact-lens tear glucose monitoring. IEEE J Solid St Circ 2012;47(1):335-44
  • Rhythm Technologies, Inc. Zio® XT Patch. Available from: www.irhythmtech.com/zio-solution/zio-patch/ [Last accessed on 25 April 2014]
  • Corventis Inc. NUVANT Mobile Cardiac Telemetry. Available from: www.corventis.com/products/nuvant-mct/how-it-works/ [Last accessed on 25 April 2014]
  • MC10 Inc. Available from: www.mc10inc.com/ [Last accessed on 25 April 2014]
  • AliveCor Inc. Available from: www.alivecor.com/home [Last accessed on 25 April 2014]
  • Azumio Inc. Instant Heart Rate. Available from: www.azumio.com/apps/heart-rate/ [Last accessed on 25 April 2014]
  • Philips VitalSigns Camera. Available from: www.vitalsignscamera.com/ [Last accessed on 25 April 2014]
  • Welch J, Moon J, McCombie S. Early detection of the deteriorating patient: the case for a multi-parameter patient-worn monitor. Biomed Instrum Technol 2012(Suppl):57-64
  • Sanofi Company. iBGStar. Available from: www.ibgstar.us [Last accessed on 25 April 2014]
  • Health Lab Inc. Wireless Smart Gluco-Monitoring System. Available from: www.ihealthlabs.com/wireless-smart-glucose-monitoring-system-bg5.htm [Last accessed on 25 April 2014]
  • Kaiserman K, Buckingham BA, Prakasam G, et al. Acceptability and utility of the mySentry remote glucose monitoring system. J Diabetes Sci Technol 2013;7(2):356-61

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.