References
- Harman M, Banks S, Hodge W. Joint replacement design guided by clinical retrievals. J. Biomech.39(Suppl. 1), S120 (2006).
- Ho FY, Ma HM, Liau JJ, Chang TK, Yeh CR, Huang CH. Wear pattern analysis of tibial polyethylene inserts from failed total knee arthroplasty – a comparison of mobile bearing and fixed-bearing knees. J. Biomech.39(Suppl. 1), S120 (2006).
- Rieker C, Schon R, Kottig P, Shen MC, Krevolin J. In-vitro versus in-vivo analysis of metal-on-metal articulations. J. Biomech.39(Suppl. 1), S120 (2006).
- Scholz J, Bohling U. Bionic system and total hip arthroplasty. J. Biomech.39(Suppl. 1), S68 (2006).
- Oberbach T, Glien W, Begand S, Kaddick C. Luxation behaviour of different ceramic on ceramic couplings. J. Biomech.39(Suppl. 1), S123 (2006).
- Bergmann G, Graichen F, Rohlmann A et al. Instrumented orthopaedic implants –an overview. J. Biomech.39(Suppl. 1), S137 (2006).
- D’Lima DD. In vivo measurements of knee forces: current status and future directions. J. Biomech.39(Suppl. 1), S137 (2006).
- Taylor SJG, Guimaraes R, Blunn GW. Calibration techniques for a 5 DOF force-measuring telemetric total knee prosthesis. J. Biomech.39(Suppl. 1), S137 (2006).
- Taylor SJG, Robles C, Blunn GW. An inductive control interface for force-measuring telemetric implants. J. Biomech.39(Suppl. 1), S138 (2006).
- Schima H, Zrunek P, Deckert Z et al.Risk of cardiac assist devices and their peripherals. J. Biomech.39(Suppl. 1), S249 (2006).
- Kwant PB, Finocchiaro T, Steinseifer U et al. VERSUS (VEntricular Recovery SUpport System) status update August 2006. J. Biomech.39(Suppl. 1), S249 (2006).
- Duncan BW, Kopcak MW, Dudzinski DT, Noecker AM, Fukamachi K, Smith WA. The PediPump: a versatile, implantable pediatric ventricular assist device. J. Biomech.39(Suppl. 1), S249 (2006).
- Bitsch RG, Heisel C, Ball S, Schmalzried TP. Reduction of osteolysis with crosslinked polyethylene – five year in vivo results. J. Biomech.39(Suppl. 1), S138 (2006).
- Rieker C, Kottig P, Shen MC, Krevolin J. Metal-on-metal hip implants. J. Biomech.39(Suppl. 1), S139 (2006).
- Fischer A, Wimmer MA. Differences in wear mechanisms between main contact areas and stripe wear regions in metal-on-metal hip joints. J. Biomech.39(Suppl. 1), S139 (2006).
- Pourzal R, Wimmer MA, Fischer A, Schwenke T, Urban R. Determination of polyethylene wear location and volume in well functioning acetabular cups. J. Biomech.39(Suppl. 1), S140 (2006).
- Burton A, McEwan H, Farrar R, Stone MH, Jennings LM, Fisher J. In vitro wear of unicompartmental knee replacements–the effects of kinematics and femoral condylar lift-off on a fixed bearing design. J. Biomech.39(Suppl. 1), S141 (2006).
- Pacione C, Wimmer MA, Thonar EJ, Block JA. Development of a wear test for cartilage replacement materials. J. Biomech.39(Suppl. 1), S143 (2006).
- Affatato S, Leardini A, Leardini W, O’Connor JJ, Viceconti M. Wear results of a new design of ankle prosthesis. J. Biomech.39(Suppl. 1), S143 (2006).
- Bergmann G, Graichen F, Bender A, Kaab M, Rohlmann A. First in vivo measurements of contact forces in the shoulder joint. J. Biomech.39(Suppl. 1), S134 (2006).