References
- Hendrich A CM, Skierczynski BA, Lu Z. A 36-hospital time and motion study: how do medical-surgical nurses spend their time? Perm J 2008;12(3):25-34
- Horlocker TT, Burton AW, Connis RT, et al. Practice guidelines for the prevention, detection, and management of respiratory depression associated with neuraxial opioid administration. Anesthesiology 2009;110(2):218-30
- Weinger MB. Dangers of postoperative opioids: APSF workshop and white paper address prevention of post-operative respiratory complications. APSF 2006;21(4):61-88
- Institute for Safe Medication Practices. High-alert medication feature: reducing patient harm from opiates. ISMP 2007;12(4):1-4
- Deitch K, Miner J, Chudnofsky CR, et al. Does end tidal CO2 monitoring during emergency department procedural sedation and analgesia with propofol decrease the incidence of hypoxic events? A randomized, controlled trial. Ann Emerg Med 2010;55(3):258-64
- Moses JM, Alexander JL, Agus MS. The correlation and level of agreement between end-tidal and blood gas pCO2 in children with respiratory distress: a retrospective analysis. BMC Pediatr 2009;9:20
- Kartal M, Eray O, Rinnert S, et al. ETCO(2): a predictive tool for excluding metabolic disturbances in nonintubated patients. Am J Emerg Med 2011;29(1):65-9
- Cook TM, Woodall N, Frerk C. Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: anaesthesia. Br J Anaesth 2011;106(5):617-31
- Li G, Warner M, Lang BH, et al. Epidemiology of anesthesia-related mortality in the United States. 1999-2005. Anesthesiology 2009;110(4):759-65
- Kodali BS. Capnography outside the operating rooms. Anesthesiology 2013;118(1):192-201
- Delerme S, Freund Y, Renault R, et al. Concordance between capnography and capnia in adults admitted for acute dyspnea in an ED. Am J Emerg Med 2010;28(6):711-14
- Becker DE, Casabianca AB. Respiratory monitoring: physiological and technical considerations. Anesth Prog 2009;56(1):14-20; quiz 1-2
- Jaffe MB. Infrared measurement of carbon dioxide in the human breath: “breathe-through” devices from Tyndall to the present day. Anesth Analg 2008;107(3):890-904
- Yang J, Wang H, Wang B, Wang L. Accurate and stable continuous monitoring module by mainstream capnography. J Clin Monit Comput 2013. [Epub ahead of print]
- Park CI, Bendjelid K, Bonvini RF. Arterial to end-tidal CO2 pressure gradient: a bedside parameter to monitor patients with massive pulmonary embolism. Am J Emerg Med 2013;31(3):639; e1-3
- Kasuya Y, Akca O, Sessler DI, et al. Accuracy of postoperative end-tidal Pco2 measurements with mainstream and sidestream capnography in non-obese patients and in obese patients with and without obstructive sleep apnea. Anesthesiology 2009;111(3):609-15
- Jabre P, Jacob L, Auger H, et al. Capnography monitoring in nonintubated patients with respiratory distress. Am J Emerg Med 2009;27(9):1056-9
- Manara A, D’Hoore W, Thys F. Capnography as a diagnostic tool for pulmonary embolism: a meta-analysis. Ann Emerg Med 2013;62(6):584-91
- Tusman G, Scandurra A, Bohm SH, et al. Model fitting of volumetric capnograms improves calculations of airway dead space and slope of phase III. J Clin Monit Comput 2009;23(4):197-206
- Blanch L, Romero PV, Lucangelo U. Volumetric capnography in the mechanically ventilated patient. Minerva Anestesiol 2006;72(6):577-85
- Verschuren F, Sanchez O, Righini M, et al. Volumetric or time-based capnography for excluding pulmonary embolism in outpatients? J Thromb Haemost 2010;8(1):60-7
- Moreira MM, Terzi RG, Cortellazzi L, et al. Volumetric capnography: in the diagnostic work-up of chronic thromboembolic disease. Vasc Health Risk Manag 2010;6:317-19
- Kurt OK, Alpar S, Sipit T, et al. The diagnostic role of capnography in pulmonary embolism. Am J Emerg Med 2010;28(4):460-5
- Bohm SH, Maisch S, von Sandersleben A, et al. The effects of lung recruitment on the Phase III slope of volumetric capnography in morbidly obese patients. Anesth Analg 2009;109(1):151-9
- Tusman G, Groisman I, Fiolo FE, et al. Noninvasive monitoring of lung recruitment maneuvers in morbidly obese patients: the role of pulse oximetry and volumetric capnography. Anesth Analg 2014;118(1):137-44
- Fouzas S, Hacki C, Latzin P, et al. Volumetric capnography in infants with bronchopulmonary dysplasia. J Pediatr 2013;164(2):283-8
- Ribeiro MA, Silva MT, Ribeiro JD, et al. Volumetric capnography as a tool to detect early peripheric lung obstruction in cystic fibrosis patients. J Pediatr (Rio J) 2012;88(6):509-17
- Veronez L, Moreira MM, Soares ST, et al. Volumetric capnography for the evaluation of pulmonary disease in adult patients with cystic fibrosis and noncystic fibrosis bronchiectasis. Lung 2010;188(3):263-8
- Brun PM, Bessereau J, Cazes N, et al. Lung ultrasound associated to capnography to verify correct endotracheal tube positioning in prehospital. Am J Emerg Med 2012;30(9):2080; e5-6
- Almeida CC, Almeida-Junior AA, Ribeiro MA, et al. Volumetric capnography to detect ventilation inhomogeneity in children and adolescents with controlled persistent asthma. J Pediatr (Rio J) 2011;87(2):163-8
- Liu JM, Hu HC, Shi MH, et al. The significance of volumetric capnography in assessment of asthmatic acute exacerbation staging. Chinese Zhonghua Jie He He Hu Xi Za Zhi 2008;31(3):186-90
- Arakawa H, Kaise M, Sumiyama K, et al. Does pulse oximetry accurately monitor a patient’s ventilation during sedated endoscopy under oxygen supplementation? Singapore Med J 2013;54(4):212-15
- Mora Capin A, Miguez Navarro C, Lopez Lopez R, Maranon Pardillo R. [Usefulness of capnography for monitoring sedoanalgesia: influence of oxygen on the parameters monitored]. An Pediatr (Barc) 2014;80(1):41-6; Utilidad de la capnografia en la monitorizacion durante procedimientos de sedoanalgesia. Influencia de la administracion de oxigeno en los parametros monitorizados
- Green SM, Krauss B. Supplemental oxygen during propofol sedation: yes or no? Ann Emerg Med 2008;52(1):9-10
- Langhan ML, Chen L, Marshall C, Santucci KA. Detection of hypoventilation by capnography and its association with hypoxia in children undergoing sedation with ketamine. Pediatr Emerg Care 2011;27(5):394-7
- Waugh JB, Epps CA, Khodneva YA. Capnography enhances surveillance of respiratory events during procedural sedation: a meta-analysis. J Clin Anesth 2011;23(3):189-96
- Restrepo RD, Hirst KR, Wittnebel L, Wettstein R. AARC clinical practice guideline: transcutaneous monitoring of carbon dioxide and oxygen: 2012. Respir Care 2012;57(11):1955-62
- Cote CJ, Wax DF, Jennings MA, et al. Endtidal carbon dioxide monitoring in children with congenital heart disease during sedation for cardiac catheterization by nonanesthesiologists. Paediatr Anaesth 2007;17(7):661-6
- Isbell CL, Batchinsky AI, Hetz KM, et al. Correlation between capnography and arterial carbon dioxide before, during, and after severe chest injury in swine. Shock 2012;37(1):103-9
- American Society of Anesthesiologists. Continuum of depth of sedation: definition of general anesthesia and levels of sedation/analgesia. Standards, Guidelines, Statements and Other Documents 2009. Available from: www.asahq.org/For-Members/Standards-Guidelines-and-Statements.aspx [Last accessed 23 January 2014]
- Friedrich-Rust M, Welte M, Welte C, et al. Capnographic monitoring of propofol-based sedation during colonoscopy. Endoscopy 2013;46(3):236-44
- Pino RM. The nature of anesthesia and procedural sedation outside of the operating room. Curr Opin Anaesthesiol 2007;20(4):347-51
- Sacchetti A, Senula G, Strickland J, Dubin R. Procedural sedation in the community emergency department: initial results of the ProSCED registry. Acad Emerg Med 2007;14(1):41-6
- Papachristou GI, Gleeson FC, Papachristou DJ, et al. Endoscopist administered sedation during ERCP: impact of chronic narcotic/benzodiazepine use and predictive risk of reversal agent utilization. Am J Gastroenterol 2007;102(4):738-43
- Beitz A, Riphaus A, Meining A, et al. Capnographic monitoring reduces the incidence of arterial oxygen desaturation and hypoxemia during propofol sedation for colonoscopy: a randomized, controlled study (ColoCap Study). Am J Gastroenterol 2012;107(8):1205-12
- Qadeer MA, Vargo JJ, Dumot JA, et al. Capnographic monitoring of respiratory activity improves safety of sedation for endoscopic cholangiopancreatography and ultrasonography. Gastroenterology 2009;136(5):1568-76; quiz 819-20
- Burton F. Towards evidence based emergency medicine: best BETs from the Manchester royal infirmary. BET 2: should capnography be routinely used during procedural sedation in the emergency department? EMJ 2012;29(2):164-6
- Welliver M. Why capnography for procedural sedation? Gastroenterol Nurs 2012;35(6):423-5
- Schlag C, Worner A, Wagenpfeil S, et al. Capnography improves detection of apnea during procedural sedation for percutaneous transhepatic cholangiodrainage. Can J Gastroenterol 2013;27(10):582-6
- Slagelse C, Vilmann P, Hornslet P, et al. The role of capnography in endoscopy patients undergoing nurse-administered propofol sedation: a randomized study. Scand J Gastroenterol 2013;48(10):1222-30
- Lightdale JR, Goldmann DA, Feldman HA, et al. Microstream capnography improves patient monitoring during moderate sedation: a randomized, controlled trial. Pediatrics 2006;117(6):e1170-8
- Yldzdas D, Yapcoglu H, Ylmaz HL. The value of capnography during sedation or sedation/analgesia in pediatric minor procedures. Pediatr Emerg Care 2004;20(3):162-5
- Anderson JL, Junkins E, Pribble C, Guenther E. Capnography and depth of sedation during propofol sedation in children. Ann Emerg Med 2007;49(1):9-13
- Yarchi D, Cohen A, Umansky T, et al. Assessment of end-tidal carbon dioxide during pediatric and adult sedation for endoscopic procedures. Gastrointest Endosc 2009;69(4):877-82
- Eipe N, Doherty DR. A review of pediatric capnography. J Clin Monit Comput 2010;24(4):261-8
- Borland M, Esson A, Babl F, Krieser D. Procedural sedation in children in the emergency department: a PREDICT study. Emerg Med Australas 2009;21(1):71-9
- Pasero C, McCaffery M. Key concepts in analgesic therapy (Chapter 12) and management of opioid-induced adverse effects. Pain assessment and pharmacologic management (Chapter 19). Mosby Elsevier; St. Louis, Missouri, USA: 2011
- Jarzyna D, Jungquist CR, Pasero C, et al. American society for pain management nursing guidelines on monitoring for opioid-induced sedation and respiratory depression. Pain Manag Nurs 2011;12(3):118-45; e10
- Fecho K, Jackson F, Smith F, Overdyk FJ. In-hospital resuscitation: opioids and other factors influencing survival. Ther Clin Risk Manag 2009;5:961-8
- The eight annual healthgrades patient saferty in american hospitals study. 2011. Available from: www.cpmhealthgrades.com/CPM/assets/File/HealthGradesPatientSafetyInAmericanHospitalsStudy2011.pdf [Last accessed 23 January 2014]
- James JT. A new, evidence-based estimate of patient harms associated with hospital care. J Patient Saf 2013;9(3):122-8
- Overdyk FJ, Carter R, Maddox RR, et al. Continuous oximetry/capnometry monitoring reveals frequent desaturation and bradypnea during patient-controlled analgesia. Anesth Analg 2007;105(2):412-18
- Institute ECR. Top 10 Health Technology Hazards for 2013. 2012.41(11):6-8. Available from: www.ecri.org/Documents/Secure/Health_Devices_Top_10_Hazards_2013.pdf [Last accessed 23 January 2014]
- CDC. CDC’s Top Ten: 5 Health Achievements in 2013 and 5 Health Threats in 2014. 2013. Available from: www.cdc.gov/injury/about/focus-rx.html [Last accessed 23 January 2014]
- Services CfMaM. Measure application partnership, national quality forum, pre-rulemaking report: 2013 recommendation on measures under consideration by HHS. final report, February 2013. Available from: www.qualityforum.org/WorkArea/linkit.aspx?LinkIdentifier=id&ItemID=73579 [Last accessed 23 January 2014]
- Williams CK, Maddox RR. Implementation of an i.v. medication safety system. Am J Health Syst Pharm 2005;62(5):530-6
- Hutchison R, Rodriguez L. Capnography and respiratory depression. Am J Nurs 2008;108(2):35-9
- Burton JH, Harrah JD, Germann CA, Dillon DC. Does end-tidal carbon dioxide monitoring detect respiratory events prior to current sedation monitoring practices? Acad Emerg Med 2006;13(5):500-4
- Pohlenz P, Woodward K, Rosacker L, Nickel B. Capnography monitoring for patient controlled analgesia. Abstract Presented at the 2011 AARC Congress; Tampa, FL, USA; 6 November 2011
- Fox D, Wencel M. Integral role of respiratory therapists in a comprehensive pain management program using end tidal co2 monitoring. Abstract Presented at the 2011 AARC Congress; Tampa, Fl, USA; 6 November 2011
- Weber P. High risk patient protocol preventing respiratory complications. Abstract Presented at the 2011 AARC Congress; Tampa, Fl, USA; 6 November 2011
- Nuccio PF, Jackson MR. End-tidal CO2 measurements with noninvasive ventilation. J Intern Res Soc 2007;104(6):S111