513
Views
96
CrossRef citations to date
0
Altmetric
Review

The use of titanium and stainless steel in fracture fixation

&
Pages 843-853 | Published online: 09 Jan 2014

References

  • Rüedi TP, Buckley RE, Moran CG. AO Philosophy and evolution. In: AO Principles of Fracture Management 2nd Edition. Rüedi TP, Buckley RE, Moran CG (Eds). Thieme NY, USA, 1, 1–9 (2007).
  • Disegi J, Eschbach L. Stainless steel in bone surgery. Injury31(Suppl. 4), D2–D6 (2000).
  • Disegi J. AO ASIF wrought 18% chromium-14% nickel-2.5% molybdenum stainless steel implant material. AO ASIF technical Commission pamphlet, 1st edition (1998).
  • Disegi J. AO ASIF unalloyed titanium implant material. AO ASIF technical Commission pamphlet, 4th edition (1998).
  • Pohler OEM. Unalloyed titanium for implants in bone surgery. Injury31, 7–13 (2000).
  • Wagner M, Frigg R. Internal fixators: concepts and cases using LCP and LISS. In: AO Manual of Fracture Management. Buckley R, Gautier E, Schütz M, Sommer C (Eds). Thieme, NY, USA, 3, 87–159 (2006).
  • Wagner M, Frigg R. Internal fixators: concepts and cases using LCP and LISS. In: AO Manual of Fracture Management. Buckley R, Gautier E, Schütz M, Sommer C (Eds). Thieme, NY, USA, 4, 163–179 (2006).
  • Cleek TM, Reynolds KJ, Hearn TC. Effect if screw torque level on cortical bone pullout strength. J. Orthop. Trauma21(2), 117–123 (2007).
  • Disegi JA. Titanium alloys for fracture fixation implants. Injury31(Suppl. 4), 14–17 (2000).
  • Albreksston T, Hansson HA. An ultrastructural characterisation of the interface between bone and sputtered titanium or steel surfaces. Biomaterials7, 201–205 (1986).
  • Pearce AI, Pearce SG, Schwieger K et al. Effect of surface topography on removal of cortical bone screws in a novel sheep model. J. Orthop. Res.26(10), 1377–1383 (2008).
  • Hayes JS, Vos DI, Hahn J, Pearce SG, Richards RG. An in vivo evaluation of surface polishing of TAN intramedullary nails for ease of removal. Eur. Cells Mat.18, 15–26 (2009).
  • Degasne I, Basle MF, Demais V et al. Effects of roughness, fibronectin and vitronectin on attachment, spreading, and proliferation of human osteoblast-like cells (SaOs-2) on titanium surfaces. Calcif. Tissue Int.64(6), 499–507 (1999).
  • Yang Y, Cavin R, Ong JL. Protein adsorption on titanium surfaces and their effect on osteoblast attachment. J. Biomed. Mater. Res. A.67, 344–349 (2003).
  • Textor M, Sittig C, Frauchiger V, Tosatti S, Brunette DM. Properties and biological significance of natural oxide films on titanium and its alloys In: Titanium in Medicine. Brunette DM, Tengvall P, Textor M, Thomsen P (Eds). Springer, NY, USA, 7, 171–230 (2001).
  • Morita M, Sasada T, Hayashi H, Tsukamoto Y. The corrosion fatigue properties of surgical implants in a living body. J. Biomed. Mater. Res.22(6), 529–540 (1988).
  • Hanawa T. Metal ion release from metal implants. Mater. Sci. Eng. C24, 745–752 (2004).
  • Shellock FG, Crues JV. MR procedures: biologic effects, safety, patient care. Radiology232, 635–652 (2004).
  • Rudisch A, Kremser C, Peer S, Kathrein A, Judmaier W, Daniaux H. Metallic artifacts in magnetic resonance imaging of patients with spinal fusion: a comparison of implant materials and imaging sequences. Spine23, 692–699 (1993).
  • Suh JS, Jeong EK, Shin KH et al. Minimising artifacts caused by metallic implants at MR imaging: experimental and clinical studies. AJR171, 1207–1213 (1998).
  • Eschbach L. 10 frequently asked questions 3D-surface magnetic resonance imaging in patients with metal implants. First edition. AO ASIF Materials Expert Group 5–25 (2003).
  • Case CP, Langkamer VG, James C et al. Widespread dissemination of metal debris from implants. J. Bone Joint Surg. Br.76(5), 701–712 (1994).
  • Keegan GM, Learmonth ID, Case CP. Orthopaedic metals and their potential toxicity in the arthroplasty patient. J. Bone Joint Surg. Br.89(5), 567–573 (2007).
  • Valko M, Rhodes CJ, Moncol J, Izakovic M, Mazur M. Free radicals, metals and antioxidants in oxidative stress-induced cancer. Chem. Biol. Interact160, 1–40 (2006).
  • Olivieri G, Novakovic M, Savaskan E et al. The effects of β-estradiol on SHSY5Y neuroblastoma cells during heavy metal induced oxidative stress, neurotoxicity and betaamyloid secretion. Neuroscience113, 849–855 (2002).
  • Elbetieha A, Al-Hamood MH. Long-term exposure of male and female mice to trivalent and hexavalent chromium compounds: effect on fertility. Toxicology116, 39–47 (1997).
  • Kanojia RK, Junaid M, Murthy RC. Embryo and fetotoxicity of hexavalent chromium: a long-term study. Toxicol. Lett.95(3), 165–172 (1998).
  • Domingo J. Metal-induced developmental toxicity in mammals: a review. J. Toxicol. Environ. Health42, 123–141 (1994).
  • Oliveira H, Santos TM, Ramalho-Santos J, de Lourdes Pereira M. Histopathological effects of hexavalent chromium in mouse kidney. Bull. Environ. Contam. Toxicol.76, 977–983 (2006).
  • Hallab NJ, Caicedo M, Finnegan A, Jacobs JJ. Th1 type lymphocyte reactivity to metals in patients with total hip athroplasty. J. Orthop. Surg. Res.3, 6–16 (2008).
  • Doorn PF, Campbell PA, Worrall J, Benya PD, McKellop HA, Amstutz HC. Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. J. Biomed. Mater. Res.42(1), 103–111 (1998).
  • Elfick AP, Green SM, Krikler S, Unsworth A. The nature and dissemination of UHMWPE wear debris retrieved from periprosthetic tissue of THR. J. Biomed. Mater. Res. A.65(1), 95–108 (2003).
  • Morgan MS, Schaller KH. An analysis of criteria for biological limit values developed in Germany and in the United States. Int. Arch. Occup. Environ. Health.72(4), 195–204 (1999).
  • Schaffer AW, Pilger A, Engelhardt C, Zweymueller K, Ruediger HW. Increased blood cobalt and chromium after total hip replacement. J. Toxicol. Clin. Toxicol.37(7), 839–844 (1999).
  • Pilger A, Schaffer A, Rüdiger HW, Osterode W. Urinary 8-hydroxydeoxyguanosine and sister chromatid exchanges in patients with total hip replacements. J. Toxicol. Environ. Health A.65(9), 655–664 (2002).
  • Lhotka C, Szekeres T, Steffan I, Zhuber K, Zweymüller K. Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements. J. Orthop. Res.21(2), 189–195 (2005).
  • Kasai Y, Iida R, Uchida A. Metal concentrations in the serum and hair of patients with titanium alloy spinal implants. Spine15, 1320–1326 (2003).
  • Hayes JS, Seidenglanz U, Pearce SG, Archer CW, Richards RG. Surface polishing positively influences ease of fracture fixation plate and screw removal. Eur. Cells Mat.19, 117–126 (2010).
  • Klinger MM, Rahemtulla F, Prince CW, Lucas LC, Lemons JE. Proteoglycans at the bone-implant interface. Crit. Rev. Oral Biol. Med.9(4), 449–463 (1998).
  • Davies JE. Mechanisms of endosseous integration. Int. J. Prosthodont.11(5), 391–400 (1998).
  • Hayes JS, Richards RG. Surfaces to control tissue adhesion for osteosynthesis with metal implants: in vitro and in vivo studies to bring solutions to the patient. Expert Rev. Med. Devices7(1), 131–142 (2010).
  • Tay SC, Theo LC. Soft tissue complications in Osteosynthesis. In: Osteosynthesis In The Hand: Current Concepts. Herren DB, Nagy L, Campbell D (Eds). Karger, Basel, Switzerland, 135–141 (2008).
  • Sinicropi SM, Su BW, Raia FJ, Parisien M, Strauch RJ, Rosenwasser MP. The effects of implant composition on extensor tenosynovitis in a canine distal radius fracture model. J. Hand Surg. Am.30, 300–307 (2005).
  • Klöppel H, Wieling R, Rahn BA, Richards RG. Influence of stainless steel implant surface microtopography on boney integration. Proceedings from the 18th European Conference on Biomaterials, October 1–4, Stuttgart, Germany (2003).
  • Meredith DO, Riehle MO, Curtis AS, Richards RG. Microtopography of metal surfaces influence fibroblast growth by modifying cell shape, cytoskeleton and adhesion. J. Orthop. Res.25(11), 1523–1533 (2007).
  • Im GI, Lee KB. Difficulties in removing ACE tibial intramedullary nail. Int. Orthop.27, 355–358 (2003).
  • Milia MJ, Vincent AB, Bosse MJ. Retrograde removal of an incarcerated solid titanium femoral nail after subtrochanteric fracture. J. Orthop. Trauma17, 521–524 (2003).
  • Woodruff MJ, Hanson JR, Shaw DL. Intramedullary tibial nails: a novel approach to removal when the standard method is not possible. Injury34, 789–790 (2003).
  • Gösling T, Hufner T, Hankemeier S, Zelle BA, Muller-Heine A, Krettek C. Femoral nail removal should be restricted in asymptomatic patients. Clin. Orthop. Relat. Res.423, 222–226 (2004).
  • Hamilton P, Doig S, Williamson O. Technical difficulty of metal removal after LISS plating. Injury35, 626–628 (2004).
  • Georgiadis GM, Gove NK, Smith AD, Rodway IP. Removal of the less invasive stabilisation system. J. Orthop. Trauma18, 562–564 (2004)
  • Hayes JS, Khan IM, Archer CW, Richards RG. The role of surface microtopography in the modulation of osteoblast differentiation. Eur. Cells Mat.20, 98–108 (2010)
  • Hauke C, Schlegel U, Melcher GA. Local infection in relation to different implant materials. An experimental study using stainless steel and titanium solid, unlocked intramedullary nails in rabbits. Orthop. Trans.21, 835–836 (1997).
  • Arens ST, Schlegel U, Printzen G, Ziegler WJ, Perren SM, Hansis M. Influence of materials for fixation implants on local infection. An experimental study of steel versus titanium DC-plates in rabbits. J. Bone Joint Surg.78, 647–651 (1996).
  • Moriarty TF, Debefve L, Boure L, Campoccia D, Schlegel U, Richards RG. Influence of material and microtopography on the development of local infection in vivo: experimental investigation in rabbits. Int. J. Artif. Organs32(9), 663–670 (2009).
  • Neuhoff D, Thompson RE, Frauchiger VM, Ganser A, Steiner A, Ito K. Anodic plasma chemical treatment of titanium Schanz screws reduces pin loosening. J. Orthop. Trauma19(8), 543–550 (2005).
  • Leung F, Tu YK, Chew WY, Chow SP. Comparison of external and percutaneous pin fixation with plate fixation for intra-articular distal radial fractures. A randomized study. J. Bone Joint Surg. Am.90(1), 16–22 (2008).
  • Pieske O, Geleng P, Zaspel J, Piltz S. Titanium alloy pins versus stainless steel pins in external fixation at the wrist: a randomized prospective study. J. Trauma64(5), 1275–1280 (2008).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.