102
Views
0
CrossRef citations to date
0
Altmetric
Original Research

The Short-Term Patency Rate of a Saphenous Vein Bridge Using the No-Touch Technique in off-Pump Coronary Artery Bypass Grafting in Vein Harvesting

, , , , &
Pages 2281-2288 | Published online: 03 Jun 2021

References

  • FitzGibbon GM, Burton JR, Leach AJ. Coronary bypass graft fate: angiographic grading of 1400 consecutive grafts early after operation and of 1132 after one year. Circulation. 1978;57(6):1070–1074. doi:10.1161/01.CIR.57.6.1070
  • Goldman S, Zadina K, Moritz T, et al. Long-term patency of saphenous vein and left internal mammary artery grafts after coronary artery bypass surgery: results from a Department of Veterans Affairs Cooperative Study. J Am Coll Cardiol. 2004;44(11):2149–2156. doi:10.1016/j.jacc.2004.08.064
  • Souza DS, Christofferson RH, Bomfim V, Filbey D. “No-touch” technique using saphenous vein harvested with its surrounding tissue for coronary artery bypass grafting maintains an intact endothelium. Scand Cardiovasc J. 1999;33(6):323–329. doi:10.1080/14017439950141362
  • Samano N, Geijer H, Bodin L, et al. The no-touch saphenous vein graft in elderly coronary bypass patients with multiple comorbidities is a promising conduit to substitute the left internal thoracic artery. J Thorac Cardiovasc Surg. 2017;154(2):457–466.e3. doi:10.1016/j.jtcvs.2017.03.048
  • Ishizawa A, Hamasaki A, Uchida T, Sadahiro M. A novel harvesting technique for a no-touch saphenous vein graft using the THUNDERBEAT device. Multimed Man Cardiothorac Surg. 2018;2018.
  • Souza DS, Johansson B, Bojö L, et al. Harvesting the saphenous vein with surrounding tissue for CABG provides long-term graft patency comparable to the left internal thoracic artery: results of a randomized longitudinal trial. J Thorac Cardiovasc Surg. 2006;132(2):373–378. doi:10.1016/j.jtcvs.2006.04.002
  • Hamon M, Geindreau D, Guittet L, Bauters C, Hamon M. Additional diagnostic value of new CT imaging techniques for the functional assessment of coronary artery disease: a meta-analysis. Eur Radiol. 2019;29(6):3044–3061. doi:10.1007/s00330-018-5919-8
  • Mohr FW, Rastan AJ, Serruys PW, et al. Complex coronary anatomy in coronary artery bypass graft surgery: impact of complex coronary anatomy in modern bypass surgery? Lessons learned from the SYNTAX trial after two years. J Thorac Cardiovasc Surg. 2011;141(1):130–140. doi:10.1016/j.jtcvs.2010.07.094
  • Ran J, Liu Y, Li Y, et al. The effect of endoscopic vein harvesting in coronary artery bypass surgery. J Thorac Dis. 2020;12(5):1991–1998. doi:10.21037/jtd-20-250
  • Meirson T, Orion E, Avrahami I. Numerical analysis of venous external scaffolding technology for saphenous vein grafts. J Biomech. 2015;48(10):2090–2095. doi:10.1016/j.jbiomech.2015.03.011
  • Webb CM, Orion E, Taggart DP, Channon KM, Di Mario C. OCT imaging of aorto-coronary vein graft pathology modified by external stenting: 1-year post-surgery. Eur Heart J Cardiovasc Imaging. 2016;17(11):1290–1295. doi:10.1093/ehjci/jev310
  • Parang P, Arora R. Coronary vein graft disease: pathogenesis and prevention. Can J Cardiol. 2009;25(2):e57–e62. doi:10.1016/S0828-282X(09)70486-6
  • Souza DS, Arbeus M, Botelho Pinheiro B, Filbey D. The no-touch technique of harvesting the saphenous vein for coronary artery bypass grafting surgery. Multimed Man Cardiothorac Surg. 2009;2009(731):mmcts.2008.003624. doi:10.1510/mmcts.2008.003624
  • Angelini GD, Passani SL, Breckenridge IM, Newby AC. Nature and pressure dependence of damage induced by distension of human saphenous vein coronary artery bypass grafts. Cardiovasc Res. 1987;21(12):902–907. doi:10.1093/cvr/21.12.902
  • Khaleel MS, Dorheim TA, Duryee MJ, et al. High-pressure distention of the saphenous vein during preparation results in increased markers of inflammation: a potential mechanism for graft failure. Ann Thorac Surg. 2012;93(2):552–558. doi:10.1016/j.athoracsur.2011.10.035
  • Nolte A, Secker S, Walker T, et al. Veins are no arteries: even moderate arterial pressure induces significant adhesion molecule expression of vein grafts in an ex vivo circulation model. J Cardiovasc Surg. 2011;52(2):251–259.
  • Dreifaldt M, Souza DS, Loesch A, et al. The “no-touch” harvesting technique for vein grafts in coronary artery bypass surgery preserves an intact vasa vasorum. J Thorac Cardiovasc Surg. 2011;141(1):145–150. doi:10.1016/j.jtcvs.2010.02.005
  • Samano N, Souza D, Dashwood MR. Saphenous veins in coronary artery bypass grafting need external support [published online ahead of print, 2020 Dec 13]. Asian Cardiovasc Thorac Ann. 2020;218492320980936.
  • Fernández-Alfonso MS, Gil-Ortega M, Aranguez I, et al. Role of PVAT in coronary atherosclerosis and vein graft patency: friend or foe? Br J Pharmacol. 2017;174(20):3561–3572. doi:10.1111/bph.13734
  • Simonsen U, Boedtkjer E. New roles of factors from perivascular tissue in regulation of vascular tone. Acta Physiol. 2016;216(2):159–162.
  • Inaba Y, Yamazaki M, Ohono M, et al. No-touch saphenous vein graft harvesting technique for coronary artery bypass grafting. Gen Thorac Cardiovasc Surg. 2020;68(3):248–253. doi:10.1007/s11748-019-01186-4
  • Kim YH, Oh HC, Choi JW, Hwang HY, Kim KB. No-touch saphenous vein harvesting may improve further the patency of saphenous vein composite grafts: early outcomes and 1-year angiographic results. Ann Thorac Surg. 2017;103(5):1489–1497. doi:10.1016/j.athoracsur.2016.09.024
  • Watts KC, Marble AE, Sarwal SN, Kinley CE, Watton J, Mason MA. Simulation of coronary artery revascularization. J Biomech. 1986;19(7):491–499. doi:10.1016/0021-9290(86)90122-3