400
Views
3
CrossRef citations to date
0
Altmetric
Original Research

Nasal Prongs: Risks, Injuries Incidence and Preventive Approaches Associated with Their Use in Newborns

ORCID Icon, ORCID Icon, ORCID Icon, ORCID Icon & ORCID Icon
Pages 527-537 | Published online: 19 Jun 2020

References

  • Morley SL. Non-invasive ventilation in paediatric critical care. Paediatr Respir Rev. 2016;20:24–31. doi:10.1016/j.prrv.2016.03.001
  • Greenough A, Lingam I. Invasive and non-invasive ventilation for prematurely born infants - current practice in neonatal ventilation. Expert Rev Respir Med. 2016;10(2):185–192. doi:10.1586/17476348.2016.1135741
  • Gupta N, Saini SS, Murki S, Kumar P, Deorari A. Continuous positive airway pressure in preterm neonates: an update of current evidence and implications for developing countries. Indian Pediatr. 2015;52(4):319–328. doi:10.1007/s13312-015-0632-z
  • De Paoli AG, Davis PG, Faber B, Morley CJ. Devices and pressure sources for administration of nasal continuous positive airway pressure (NCPAP) in preterm neonates. Cochrane Database Syst Rev. 2008;(1):CD002977.
  • McCoskey L. Nursing care guidelines for prevention of nasal breakdown in neonates receiving nasal CPAP. Adv Neonatal Care. 2008;8(2):116–124. doi:10.1097/01.ANC.0000317260.99072.ae
  • Bonfim SFSF, Vasconcelos MGL, Sousa NFC, Silva DVC, Leal LP. Nasal septum injury in preterm infants using nasal prongs. Rev Lat Am Enfermagem. 2014;22(5):826–833. doi:10.1590/0104-1169.3451.2486
  • Visscher MO, Adam R, Brink S, Odio M. Newborn infant skin: physiology, development, and care. Clin Dermatol. 2015;33(3):271–280. doi:10.1016/j.clindermatol.2014.12.003
  • Fischer C, Bertelle V, Hohlfeld J, Forcada-Guex M, Stadelmann-Diaw C, Tolsa JF. Nasal trauma due to continuous positive airway pressure in neonates. Arch Dis Child Fetal Neonatal Ed. 2010;95(6):F447–451. doi:10.1136/adc.2009.179416
  • Imbulana DI, Manley BJ, Dawson JA, Davis PG, Owen LS. Nasal injury in preterm infants receiving non-invasive respiratory support: a systematic review. Arch Dis Child Fetal Neonatal Ed. 2018;103(1):F29–F35. doi:10.1136/archdischild-2017-313418
  • Bouza H. The impact of pain in the immature brain. J Matern Fetal Neonatal Med. 2009;22(9):722–732. doi:10.3109/14767050902926962
  • Coyer F, Tayyib N. Risk factors for pressure injury development in critically ill patients in the intensive care unit: a systematic review protocol. Syst Rev. 2017;6(1):1–6. doi:10.1186/s13643-017-0451-5
  • Alessi S. Evidence regarding the use of bubble continuous positive airway pressure in the extremely low birth-weight infant: benefits, challenges, and implications for nursing practice. Adv Neonatal Care. 2018;18(3):199–207. doi:10.1097/ANC.0000000000000509
  • Squires AJ, Hyndman M. Prevention of nasal injuries secondary to NCPAP application in the ELBW infant. Neonatal Netw. 2009;28(1):13–27. doi:10.1891/0730-0832.28.1.13
  • Casey JL, Newberry D, Jnah A. Early bubble continuous positive airway pressure: investigating interprofessional best practices for the NICU team. Neonatal Netw. 2016;35(3):125–134. doi:10.1891/0730-0832.35.3.125
  • Chen C-Y, Chou A-K, Chen Y-L, Chou H-C, Tsao P-N, Hsieh W-S. Quality improvement of nasal continuous positive airway pressure therapy in neonatal intensive care unit. Pediatr Neonatol. 2017;58(3):229–235. doi:10.1016/j.pedneo.2016.04.005
  • Milligan PS, Goldstein MR. Implementation of an evidence-based non-invasive respiratory support (NIRS) bundle in the NICU to decrease nasal injury complications. J Neonatal Nurs. 2017;23(2):89–98. doi:10.1016/j.jnn.2016.05.003
  • Nascimento RM, Ferreira ALC, Coutinho ACFP, Veríssimo RCSS. The frequency of nasal injury in newborns due to the use of continuous positive airway pressure with prongs. Rev Lat Am Enfermagem. 2009;17(4):489–494. doi:10.1590/S0104-11692009000400009
  • Rego MA, Martinez FE. Clinical and laboratorial repercussions of the nasal CPAP in preterm newborns. J Pediatr (Rio J). 2000;76(5):339–348. doi:10.2223/jped.125
  • Sahni R, Schiaratura M, Polin RA. Strategies for the prevention of continuous positive airway pressure failure. Semin Fetal Neonatal Med. 2016;21(3):196–203. doi:10.1016/j.siny.2016.02.008
  • Bonner KM, Mainous RO. The nursing care of the infant receiving bubble CPAP therapy. Adv Neonatal Care. 2008;8(2):78–95. doi:10.1097/01.ANC.0000317256.76201.72
  • Mangat AK, Oei JL, Chen K, Quah-Smith I, Schmolzer GM. A review of non-pharmacological treatments for pain management in newborn infants. Children. 2018;5(10):1–12.
  • Sousa NFC, Bonfim SFSF, Vasconcelos MGL, Bezerra JLO, Silva DVC, Leal LP. Prevalence of nasal septum injury in premature infants using nasal prongs. Rev Esc Enferm USP. 2013;47(6):1285–1290. doi:10.1590/S0080-623420130000600005
  • Ota NT, Davidson J, Guinsburg R. Early nasal injury resulting from the use of nasal prongs in preterm infants with very low birth weight: a pilot study. Rev Bras Ter Intensiva. 2013;25(3):245–250. doi:10.5935/0103-507X.20130042
  • Robertson NJ, McCarthy LS, Hamilton PA, Moss AL. Nasal deformities resulting from flow driver continuous positive airway pressure. Arch Dis Child Fetal Neonatal Ed. 1996;75(3):F209–212. doi:10.1136/fn.75.3.F209
  • Fox MD. Wound care in the neonatal intensive care unit. Neonatal Netw. 2011;30(5):291–303. doi:10.1891/0730-0832.30.5.291
  • Gunlemez A, Isken T, Gokalp AS, Turker G, Arisoy EA. Effect of silicon gel sheeting in nasal injury associated with nasal CPAP in preterm infants. Indian Pediatr. 2010;47(3):265–267. doi:10.1007/s13312-010-0047-9
  • Pandita A, Mishra N, Gupta G, Shukla A. Neonatal facial palsy, a case series: is CPAP the culprit? BMJ Case Rep. 2018;bcr-2018–224842. doi:10.1136/bcr-2018-224842
  • Yong SC, Chen SJ, Boo NY. Incidence of nasal trauma associated with nasal prong versus nasal mask during continuous positive airway pressure treatment in very low birthweight infants: a randomised control study. Arch Dis Child Fetal Neonatal Ed. 2005;90(6):F480–483. doi:10.1136/adc.2004.069351
  • Galetto SGS, Nascimento ERP, Hermida PMV, Malfussi LBH. Medical device-related pressure injuries: an integrative literature review. Rev Bras Enferm. 2019;72(2):505–512. doi:10.1590/0034-7167-2018-0530
  • Newnam KM, McGrath JM, Salyer J, Estes T, Jallo N, Bass WT. A comparative effectiveness study of continuous positive airway pressure-related skin breakdown when using different nasal interfaces in the extremely low birth weight neonate. Appl Nurs Res. 2015;28(1):36–41. doi:10.1016/j.apnr.2014.05.005
  • Davis PG, Morley CJ, Owen LS. Non-invasive respiratory support of preterm neonates with respiratory distress: continuous positive airway pressure and nasal intermittent positive pressure ventilation. Semin Fetal Neonatal Med. 2009;14(1):14–20. doi:10.1016/j.siny.2008.08.003