110
Views
1
CrossRef citations to date
0
Altmetric
Original Research

Clinical Outcomes of a Modified Laryngeal Mask Airway (LMA® Gastro™ Airway) During Esophagogastroduodenoscopy in Children and Adolescents: A Randomized Study

, ORCID Icon, , , ORCID Icon, , ORCID Icon & ORCID Icon show all
Pages 277-282 | Published online: 21 Sep 2020

References

  • Dar AQ, Shah ZA. Anesthesia and sedation in pediatric gastrointestinal endoscopic procedures: a review. World J Gastrointest Endosc. 2010;2:257–262. doi:10.4253/wjge.v2.i7.257
  • Friedt M, Welsch S. An update on pediatric endoscopy. Eur J Med Res. 2013;18:18–24. doi:10.1186/2047-783X-18-24
  • Francois A, Pedone E. Supraglottic airway for upper gastrointestinal endoscopy in children: a review of 10years’ experience. J Clin Anesth. 2018;45:69–70. doi:10.1016/j.jclinane.2017.12.028
  • Balaban O, Kamata M, Hakim M, et al. The effect of esophagogastroduodenoscopy probe insertion on the intracuff pressure of airway devices in children during general anesthesia. J Anesth. 2017;31:278–281. doi:10.1007/s00540-016-2297-8
  • Nott MR, Noble PD, Parmar M. Reducing the incidence of sore throat with the laryngeal mask airway. Eur J Anaesthesiol. 1998;15:153–157. doi:10.1111/j.0265-0215.1998.00257.x
  • Brimacombe J, Holyoake L, Keller C, et al. Pharyngolaryngeal, neck, and jaw discomfort after anesthesia with the face mask and laryngeal mask airway at high and low cuff volumes in males and females. Anesthesiology. 2000;93:26–31. doi:10.1097/00000542-200007000-00009
  • Krishna SG, Ramesh A, Jatana KR, et al. A technique to continuously measure the intracuff pressure: an in vivo demonstration of its accuracy. Pediatr Anesth. 2014;24:999–1004. doi:10.1111/pan.12437
  • Gopalakrishnan S, Barry N, Rice J, et al. Cuffed endotracheal tubes in infants and children: a technique to continuously measure the intracuff pressure. Inter J Pediatr Otorhinolaryngol. 2013;77:1135–1138. doi:10.1016/j.ijporl.2013.04.020
  • Wong JG, Heaney M, Chambers NA, et al. Impact of laryngeal mask airway cuff pressures on the incidence of sore throat in children. Paediatr Anaesth. 2009;19:464–469. doi:10.1111/j.1460-9592.2009.02968.x
  • Hussain SA. Anesthesia for pediatric endoscopies. Int Anesthesiol Clin. 2006;44:81–93. doi:10.1097/01.aia.0000196256.91774.0b
  • Takzare A, Soltani AE, Maleki A. Comparison of propofol-ketamine versus propofol-fentanyl for pediatric sedation during upper gastrointestinal endoscopy. Arch Anesthesiol Crit Care. 2016;2:216–225.
  • Coté GA, Hovis RM, Ansstas MA, et al. Incidence of sedation-related complications with propofol use during advanced endoscopic procedures. Clin Gastroenterol Hepatol. 2010;8:137–142. doi:10.1016/j.cgh.2009.07.008
  • Qadeer MA, Qadeer MA, Lopez AR, et al. Hypoxemia during moderate sedation for gastrointestinal endoscopy: causes and associations. Digestion. 2011;84:37–45. doi:10.1159/000321621
  • Agostoni M, Fanti L, Gemma M, et al. Adverse events during monitored anaesthesia care for GI endoscopy: an 8-year experience. Gastrointest Endosc. 2011;74:266–275. doi:10.1016/j.gie.2011.04.028
  • Tobias JD. The laryngeal mask airway: a review for the emergency room physician. Pediatr Emerg Care. 1996;12:370–373. doi:10.1097/00006565-199610000-00012
  • Pollack Jr CV. The laryngeal mask airway: a comprehensive review for the emergency physician. J Emerg Med. 2001;20:53–66. doi:10.1016/S0736-4679(00)00273-0
  • William A, Chambers NA, Erb TO, von Ungern-sternberg BS. Incidence of sore throat in children following use of flexible laryngeal mask airways - impact of an introducer device. Paediatr Anaesth. 2010;20:839–843. doi:10.1111/j.1460-9592.2010.03372.x
  • Jagannathan N, Sohn LE, Sawardekar A, et al. A randomised comparison of the LMA Supreme™ and LMAProSeal™ in children. Anaesthesia. 2012;67:632–639. doi:10.1111/j.1365-2044.2012.07088.x
  • Terblanche NC, Middleton C, Choi-Lundberg DL, et al. Efficacy of a new dual channel laryngeal mask airway, the LMA® Gastro™ Airway, for upper gastrointestinal endoscopy: a prospective observational study. Br J Anaesth. 2018;120:353–360. doi:10.1016/j.bja.2017.11.075
  • Schmutz A, Loeffler T, Schmidt A, et al. LMA Gastro™ Airway is feasible during upper gastrointestinal interventional endoscopic procedures in high risk patients: a single-center observational study. BMC Anesthesiol. 2020;20:40. doi:10.1186/s12871-020-0938-9